Elation Professional 250 Define the number of steps in Run, Editing the channels of each scene

Page 18

1.Press [MODE/ESC] to enter the main menu (display flashing).

2.Press [UP] or [DOWN] button to select “EDIT”.

- Define the number of steps in Run

With this function you can define the number of steps in the Program Run.

1. Select “STEP” by pressing [UP] or [DOWN] button.

2. Press [ENTER], the display shows “S-XX”, “X” stands for the total amount of steps you want to save, so you can call up to 48 scenes in “RUN”. For example if the “XX” is 05, it means that “RUN” will run the first 5 scenes you saved in “EDIT”.

3. Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.

Auto Save Scene

With this function you can save the scenes of this device automatically.

1.Select “REC.” by pressing [UP] or [DOWN] button.

2. Press [ENTER], the display shows “RE.XX.”, “X” stands for the scene number.

3 Press [UP] or [DOWN] to select the desired scene.

4. Press [ENTER] to confirm or Press [MODE/ESC] to return to the main menu.

- Editing the channels of each scene

With this function you can edit the program to be called up in

Run.

a) Editing via the Control Board

1. Select “SC01” by pressing [UP] or [DOWN] button.

2. Press [ENTER], the display shows “SCXX”, “X”

stands for the scene No. to be edited.

3. Change the scene No. by pressing [UP] or [DOWN]

button.

4.Press [ENTER], the display shows “C-X”, “X” stands for the channel No. Such as “C-01”, it means you are editing channel 1 of the selected scene.

5.Select the channel No. you would like to edit by pressing [UP] or [DOWN] button.

6.Press [ENTER] to enter editing for the selected channel , the fixture reacts to your settings. The display shows the DMX value of the edited channel. Such as “ 11XX”, it stands for in the channel 11 of the editing scene, the DMX value is XX , XX is a hexadecimal number value “01-FF”.

7.Adjust the desired DMX value by pressing [UP] or [DOWN] button.

8.Press [ENTER] in order to edit other channels of this scene.

9.Repeat steps 5-9 until you finish setting all the DMX values for all channels of this scene.

10. Once all the channels completed, the display will flash “TIME”

11.Press [ENTER] to edit the time needed, the display shows “TXXX”,“X” stands for the time needed to run the current scene, value “001-999”. For example, “T002” means you need 2 seconds to run the current scene.

12.Adjust the desired time by pressing [UP] or [DOWN] button.

13.Press [ENTER] to save the settings for the scene you are editing, the display will change to the next scene automatically.

14.Repeat step 3-14 to edit and other scenes, you can edit and save a maximum of 48 scenes.

17 DESIGN WASH 250 USER MANUAL V1.0 NR

Image 18
Contents Design Wash Keep this Manual for Future Needs IntroductionSafety Instructions General Guidelines Installation Instructions Installing or replacing the lampMounting the device Page Installation via the Omega holders DMX-512 connection with DMX terminator Control Board Addr Valu Program Run, Master setting DMX address setting, Slave settingSlave setting Main menuReverse display Shut off LED displayLamp on/off Lamp on/off via external controller Lamp automated on with powerDelay lamp on Pan ReverseReset Switch 16 bit/8 bitFans mode select Pan degree selectSoftware version Restore factory settingsLamp adjustment Test function of each channelClear fixture time Fixture running timeLamp running time Clear lamp timeDefine the number of steps in Run Editing the channels of each scenePage Channel 2 Cyan Color Wheel Channel 9 Zoom Channel 15 Pan fine Channel 16 Tilt fine Cleaning and Maintenance Technical Specifications Disconnect from mains before starting maintenance operation
Related manuals