Elation Professional 250 user manual Cleaning and Maintenance

Page 23

ERROR MESSAGE

When you turn on the fixture, it will make a reset first. The display may show “XXer” while there are problems with one or more channels. “XX” stands for channel 1,5,6,8,9 who has the testing sensor for positioning .

For example, when the display shows “01Er”, it means there is some error in channel 1. If there are some errors on channel 1, channel 5, channel 6 at the same time, you may see the error message “01Er”, “05Er”,”06Er” flash repeated for 5 times, and then the fixture will generate a reset signal, all the stepper reset. If the fixture remain error message after performing reset more than 3 times, it will detect whether the fixture has more than 3 errors. If the fixture has more than 3 errors (including 3 errors), all the channels can not work properly; but if the fixture has less than 3 errors, only the channels which have errors can not work properly, others can work as usual.

01Er:

(Color-wheel 1 error) This message will appear after the reset of the fixture if the magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its drive circuit on the main PCB). The color wheel is not located in the default position after the reset.

05Er:

(PAN-yoke movement error) This message will appear after the reset of the fixture if the yoke’s magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the stepping-motor is defective ( or its driving IC on the main PCB). The yoke is not located in the default position after the reset.

06Er:

(TILT-head movement error) This message will appear after the reset of the fixture if the head’s magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the main PCB). The head is not located in the default position after the reset.

08Er:

(Effect-wheel error) This message will appear after the reset of the fixture and if the magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the main PCB). The rotating gobo is not located in the default position after the reset.

09Er:

(Zoom error) This message will appear after the reset of the fixture and if the magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the main PCB). The zoom is not located in the default position after the reset.

CLEANING AND MAINTENANCE

The following points have to be considered during the inspection:

1)All screws for installing the devices or parts of the device have to be tightly connected and must not be corroded.

2)There must not be any deformations on the housing, color lenses, fixations and installation spots (ceiling, suspension, trussing).

1)Mechanically moved parts must not show any traces of wearing and must not rotate with unbalances.

2)The electric power supply cables must not show any damage, material fatigue or sediments. Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be removed.

Note: If the external flexible cable or cord of this device is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard.

22 DESIGN WASH 250 USER MANUAL V1.0 NR

Image 23
Contents Design Wash Introduction Keep this Manual for Future NeedsSafety Instructions General Guidelines Installing or replacing the lamp Installation InstructionsMounting the device Page Installation via the Omega holders DMX-512 connection with DMX terminator Control Board Addr Valu Main menu DMX address setting, Slave settingSlave setting Program Run, Master settingLamp on/off Reverse displayShut off LED display Pan Reverse Lamp automated on with powerDelay lamp on Lamp on/off via external controllerPan degree select Switch 16 bit/8 bitFans mode select ResetTest function of each channel Restore factory settingsLamp adjustment Software versionClear lamp time Fixture running timeLamp running time Clear fixture timeEditing the channels of each scene Define the number of steps in RunPage Channel 2 Cyan Color Wheel Channel 9 Zoom Channel 15 Pan fine Channel 16 Tilt fine Cleaning and Maintenance Disconnect from mains before starting maintenance operation Technical Specifications
Related manuals
Manual 2 pages 34.71 Kb Manual 1 pages 14.86 Kb