RCA LDK 4700 DC power output socket, DC power input socket, Input voltage must not exceed +17 Vdc

Page 25

LDK 5481 + LDK 4700 User’s Guide DigiLink Adapter

2-15

2.7.9 DC power output socket

Figure 2-13. DC power and tally output connector

12

43

1.Power ground

2.On air (+5V, 100 Ohm)

3.Housing

4.+12 Vdc (max. 18W)

Shield of cable directly to the connector housing.

The socket provides access to an internal tally switch. When the camera is on-air, the contact of the internal relay is closed.

Hirose 4-pin female; panel view

Panel part number: (X3) 2422 026 04675

2.7.10 DC power input socket

Caution

The input voltage must not exceed +17 Vdc.

Figure 2-14. DC power input connector

14

2 3

1.Power ground

2.-Batt sense

3.+Batt sense

4.+10.5 Vdc . . . +17 Vdc

This socket accepts a DC voltage of 12V nominal. Maximum power consumption 60W.

XLR 4-pin male: panel view (X7)

v4.0

Image 25
Contents User’s Guide FCC Class a Statement Declaration of ConformityCopyright TrademarksTable of contents LDK 5481 + LDK 4700 User’s Guide Following DigiLink accessories are available AccessoriesIntroduction Digilink system SDI coax configuration ConfigurationsCompatibility DigiLink system multicore connection DigiLink system multicore configurationStand alone multicore configuration Stand alone SDI coax configurationDigiLink system dual fiber configuration DigiLink system hybrid fiber configurationIntercom Schematic overview of the intercom routingImportant information English Safety SummarySicherheit Zusammenfassung Wichtige Hinweise DeutschAchtung VorsichtLaser safety statement US Laser safety statement EuropeFiber optic cable precautions Fiber optic transmission unitsLDK 5481/00 version multicore/coax SpecificationsLDK 5481/20 version fiber version LDK 5481 DigiLink adapter dimension sketch DimensionsControls Powering the cameraAttaching the LDK 5481 adapter to a camera head Carrying handle replacementMounting a script board Script board accessoryDigiLink adapter connector locations Adapter connectorsSDI video input connector SDI video output connectorMulticore connector Multicore connectorVideo signal VF output connector Hybrid fiber connectorVideo signal Cvbs output connector LCP / Fiber power connector Intercom headset connectorDC power input socket DC power output socketInput voltage must not exceed +17 Vdc 15. Script light power supply output connector Script light power supply socketInstall menu LDK 5481 + LDK 4700 User’s Guide DigiLink Adapter Base unit Wichtige Hinweise Deutsch Vorsicht Fiber optic transmission units Ventilation Installation informationRack mounting instructions Mains power supply chord Installation noticesFor Switzerland LDK 4700/10 version coax LDK 4700/00 version multicoreLDK 4700/20 version fiber DigiLink base unit dimension sketch Powering the base unit Controls and indicatorsIndicators Set-up itemsThis is the inactivity state of the menu Camera Number CACall and On-air signals Connecting the studio signallingDry contact signalling DigiLink base unit connector locations LDK 4700/00 DigiLink base unit connectorsAudio out connector Setup switchesBase unit setup switches Switch Function Off default Reference input connector External video input connectorTeleprompter input connector SDI Camera connectors 6 Y, Pr, Pb output connectorsCvbs output connector 10 RS-232/RS-422 control connector SDI video output connectorsMains power supply input socket DC power output connector Auxiliary connector22. Multicore connector