RCA LDK 4700 DigiLink system hybrid fiber configuration, DigiLink system dual fiber configuration

Page 9

LDK 5481 + LDK 4700 User’s Guide DigiLink system

1-5

1.4.5 DigiLink system hybrid fiber configuration

A camera head with an LDK 5481/20 fiber adapter can be connected to the LDK 4700/20 base unit using a hybrid fiber cable that carries both signal and power. The maximum cable length that can be used is 100 m (330 ft). The power consumption of the camera may reduce the maximum length of cable that can be used, so alternatively, the power for the camera can be supplied directly to the adapter from the optional LDK 5901 power supply.

Figure 1-6. DigiLink system hybrid fiber connection

LDK 5481/20

DigiLink adapter

LDK 4700/20 DigiLink Base unit

Hybrid fiber cable max. 100 m (330 ft)

SD camera head

optional LDK 5901

 

DC power supply

OCP 400/10

 

Ready

On-ai r

RS-422 with powerline LDK8121/xx max. 25 m (82 ft)

Mains power

1.4.6 DigiLink system dual fiber configuration

A camera head with an LDK 5481/20 fiber adapter can be connected to the LDK 4700/20 base unit using a dual fiber cable. The maximum cable length that can be used is 5,000 m (16,400 ft). The camera adapter must be powered locally by the optional LDK 5901 DC power supply.

Figure 1-7. DigiLink system dual fiber connection

LDK 5481/20

DigiLink adapter

LDK 4700/20 DigiLink Base unit

HybridDualfibercable maxmax.5,000.100m(16,400(330ft) ft)

SD camera head

optional LDK 5901

 

DC power supply

OCP 400/10

 

Ready

On-aii r

RS-422 with powerline LDK8121/xx max. 25 m (82 ft)

Mains power

v4.0

Image 9
Contents User’s Guide FCC Class a Statement Declaration of ConformityCopyright TrademarksTable of contents LDK 5481 + LDK 4700 User’s Guide Accessories Following DigiLink accessories are availableIntroduction Configurations Digilink system SDI coax configurationCompatibility DigiLink system multicore connection DigiLink system multicore configurationStand alone multicore configuration Stand alone SDI coax configurationDigiLink system dual fiber configuration DigiLink system hybrid fiber configurationIntercom Schematic overview of the intercom routingImportant information English Safety SummarySicherheit Zusammenfassung Wichtige Hinweise DeutschAchtung VorsichtLaser safety statement US Laser safety statement EuropeFiber optic cable precautions Fiber optic transmission unitsSpecifications LDK 5481/00 version multicore/coaxLDK 5481/20 version fiber version LDK 5481 DigiLink adapter dimension sketch DimensionsControls Powering the cameraAttaching the LDK 5481 adapter to a camera head Carrying handle replacementMounting a script board Script board accessoryDigiLink adapter connector locations Adapter connectorsSDI video input connector SDI video output connectorMulticore connector Multicore connectorHybrid fiber connector Video signal VF output connectorVideo signal Cvbs output connector LCP / Fiber power connector Intercom headset connectorDC power output socket DC power input socketInput voltage must not exceed +17 Vdc 15. Script light power supply output connector Script light power supply socketInstall menu LDK 5481 + LDK 4700 User’s Guide DigiLink Adapter Base unit Wichtige Hinweise Deutsch Vorsicht Fiber optic transmission units Installation information VentilationRack mounting instructions Mains power supply chord Installation noticesFor Switzerland LDK 4700/00 version multicore LDK 4700/10 version coaxLDK 4700/20 version fiber DigiLink base unit dimension sketch Powering the base unit Controls and indicatorsIndicators Set-up itemsThis is the inactivity state of the menu Camera Number CACall and On-air signals Connecting the studio signallingDry contact signalling DigiLink base unit connector locations LDK 4700/00 DigiLink base unit connectorsSetup switches Audio out connectorBase unit setup switches Switch Function Off default External video input connector Reference input connectorTeleprompter input connector 6 Y, Pr, Pb output connectors SDI Camera connectorsCvbs output connector SDI video output connectors 10 RS-232/RS-422 control connectorMains power supply input socket DC power output connector Auxiliary connector22. Multicore connector