LDK 5481 + LDK 4700 User’s Guide DigiLink Adapter
2.4Controls
Figure 2-2. LDK 5481 adapter controls
2 | 3 |
1
4
DC out | LCP | CVBS | VF |
1.Power source selection switch
2.Power on indicator (green)
3.Tally indicators (red)
4.Circuit breaker button (fuse)
2.4.1 Powering the camera
The power supply for the camera and the adapter (+12 Vdc) is normally supplied either via the multicore connector or via the DC IN socket. Set the power source selection switch (1) to the position that corresponds to your chosen method:
•LOC: Powered via DC IN socket
•REM:Powered via multicore
The power on indicator (2) lights when power is supplied and the camera power switch is On.
If excessive current flows in the camera or adapter, the circuit breaker (4) trips and shuts off power to all the units. If this happens, check the units for faults and if necessary take corrective action before pressing the circuit breaker button to reset the power.
v4.0