TV-IP512P ProView PoE Internet Camera
B
I/O Terminal Application
Typically used in association with programming scripts for developing applications for motion detection, event triggering, alarm notification via
Connector Pin Assignment
Sign | FUNCTION | SPECIFICATION | |
|
|
| |
O+ | Close circuit current maximum 120mA (Peak load current) | ||
|
| Open circuit voltage maximum 350V (Peak AC) | |
O- | |||
| |||
|
|
| |
I1+ | Active High voltage 5~40VDC | ||
|
| Dropout voltage 0 VDC | |
I1- | |||
|
|
| |
I2+ | Active High voltage 5~40VDC | ||
|
| Dropout voltage 0 VDC | |
I2- | |||
|
|
| |
485+ | Compliant to | ||
|
|
| |
485- |
| ||
|
|
|
Monitoring and Controlling
By entering http requests in your browser’s URL field, you can:
Monitor the status of digital input.
Drive the output switch on or off.
71