SonicWALL SRA 1200/4200 manual Lithium Battery Warning, Cable Connections

Page 55

SonicWALL SRA 1200/4200 Appliance

Regulatory Statement and Safety

Instructions

Regulatory Model/Type

Product Name

 

 

1RK23-088

SonicWALL SRA 1200

1RK23-07C

SonicWALL SRA 4200

 

 

This regulatory information can also be found in the electronic file, “SonicWALL_SRA_Regulatory_Statement.pdf,” located on the SonicWALL Web site: <http://www.sonicwall.com>.

The above SonicWALL appliances are designed to be mounted in a standard 19-inch rack mount cabinet. The following conditions are required for proper installation:

Use the mounting hardware recommended by the rack manufacturer and ensure that the rack is adequate for the application.

Four mounting screws, compatible with the rack design, must be used and hand tightened to ensure secure installation. Choose a mounting location where all four mounting holes line up with those of the mounting bars of the 19-inch rack mount cabinet.

Mount in a location away from direct sunlight and sources of heat. A maximum ambient temperature of 104º F (40º C).

Route cables away from power lines, fluorescent lighting fixtures, and sources of noise such as radios, transmitters and broadband amplifiers.

The included power cord is intended for use in North America only. For European Union (EU) customers, a power cord is not included.

Ensure that no water or excessive moisture can enter the unit.

Allow unrestricted airflow around the unit and through the vents on the side of the unit. A minimum of 1 inch (25.44mm) clearance is recommended.

Mount the SonicWALL appliances evenly in the rack in order to prevent a hazardous condition caused by uneven mechanical loading.

If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient temperature. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum recommended ambient temperature shown above.

Consideration must be given to the connection of the equipment to the supply circuit. The effect of overloading the circuits has minimal impact on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings must be used when addressing this concern.

Reliable grounding of rack-mounted equipment must be maintained. Particular attention must be given to power supply connections other than direct connections to the branch circuits such as power strips.

Lithium Battery Warning

The Lithium Battery used in the SonicWALL Internet security appliance may not be replaced by the user. The SonicWALL must be returned to a SonicWALL authorized service center for replacement with the same or equivalent type recommended by the manufacturer. If, for any reason, the battery or SonicWALL Internet security appliance must be disposed of, do so following the battery manufacturer's instructions.

Cable Connections

All Ethernet and RS232 (Console) cables are designed for intra-building connection to other equipment. Do not connect these ports directly to communication wiring or other wiring that exits the building where the SonicWALL is located.

Page 54 SonicWALL SRA 1200/4200 Appliance Regulatory Statement and Safety Instructions

Image 55
Contents Getting Started Guide SonicWALL SRA 1200/4200 Getting Started Guide Document Contents2 Document Contents This Section Setting Up Your NetworkSRA 1200 System Requirements Package Contents for the SonicWALL SRAMissing Items? SRA 4200 System Requirements What You Need to Begin Recording Configuration InformationAdministrator Information Network Configuration InformationScenario Overviews Selecting a Deployment ScenarioScenario B SRA on an Existing DMZ Accessing the Management Interface Applying Power to the SonicWALL SRATroubleshooting Connecting Your Appliance Setting Your Administrator Password Configuring Your SRA 1200/4200Adding a Local User Setting the Time ZoneNavigate to Users Local Users Click Accept Configuring SRA Network SettingsConfiguring DNS / Wins Configuring the X0 IP Address for Scenario B and Scenario CConfiguring a Default Route Navigate to the NetExtender Client Routes Adding a NetExtender Client Route192.168.200.100 to Setting Your NetExtender Address RangeScenario a Connecting Your Network Interfaces Connecting Your SRA 1200/4200Scenario C Connecting Your Network Interfaces Scenario B Connecting Your Network Interfaces20 Connecting Your SRA 1200/4200 Registering Your Appliance Product Registration Creating a MySonicWALL AccountRegistering Your SonicWALL SRA Before You RegisterService Management Services and LicensingFlexible Per-User Licensing Activating Services and SoftwareTrying or Purchasing Services 26 Services and Licensing Scenario a SRA on a New DMZ Network ConfigurationAdding a New SRA Custom Zone Connecting to a SonicWALL Security ApplianceUn-select the Allow Interface Trust checkbox Allowing a WAN SRA Connection Enter a name for the serviceEnter your Subnet Mask Navigate to the Network Address Objects Allowing an SRA LAN ConnectionClick Name for NetExtender Prerequisites Scenario B SRA on an Existing DMZAllowing WAN DMZ Connection Allowing DMZ LAN Connection Continue to Testing Your Remote Connection on Scenario C SRA on the LAN Configuring SRA LAN ConnectivityName Name for NetExtender Zone Assignment Select the Public Server Wizard option and click Next Setting Public Server AccessSelect Http and Https checkboxes, and click Next Verifying a User Connection from the Internet Testing Your Remote Connection40 Testing Your Remote Connection Upgrading Your Appliance Obtaining the Latest SRA SSL VPN Image Exporting a Copy of Your Configuration SettingsUploading a New SRA SSL VPN Image Uploaded Firmware with Factory Defaults NewUploaded Firmware New Resetting the Appliance Using SafeMode Support and Training Options Knowledge Base Customer SupportUser Forums Training Related Documentation SonicWALL Live Product Demos SonicWALL Secure Wireless Network Integrated Solutions Guide Page Safety and Regulatory Information Cable Connections Lithium Battery WarningHinweis zur Lithiumbatterie Weitere Hinweise zur MontageKabelverbindungen Complies with EN 55022 Class a and CISPR22 Class a Declaration of ConformitySWL-1RK23-088 Bmsi Statement Class a Regulatory Information for KoreaTrademarks Copyright NoticeSonicWALL SRA 1200/4200 Getting Started Guide 60 Notes SonicWALL, Inc