Housing Maintenance

Your Ikelite Housing should be given the same care and attention as your other photographic equipment. In addition to normal maintenance, we recommend your housing be returned to Ikelite (every 2-3 years or 50 dives), to be checked and pressure tested.

-Do Not leave the camera and housing in direct sunlight for prolonged periods. Heat may damage the camera.

-Do Not ship the camera in the housing.

-Before using the housing, always check the tightness of the set screw in each control knob.

Check each control gland penetrating the housing to make sure they are tight. There is a slight chance that either could vibrate loose during travel.

-Keep the back and port o-ring clean and lightly lubricated. To lubricate, remove the o-ring from the back. Put a small amount of lkelite lubricant on your fingers. Pull the o-ring through your fingers to apply a light coating of lubricant. Only apply enough lubricant to make the o-ring feel slick. Do Not stretch the o-ring. This light coating of lubricant will help to keep the o-ring from drying out and will help to show a dark sealing line when the housing back is properly sealed.

-Keep the area where the o-ring fits and the sealing surface clean.

-Rinse the housing exterior thoroughly in freshwater after each saltwater use. Depress push buttons several times during rinse. Dry with a soft cloth. Dry port to eliminate water spotting.

After several uses in saltwater, soak the housing in a mild soap solution, rinse, and dry.

-Although not recommended, if it is necessary to remove a housing push button, Do Not re-use the E-clip. Contact Ikelite for replacement E-clips (part #0319.12).

CAUTION: Never use spray lubricants as the propellant ingredient can cause the plastic housing to crack. Use only Ikelite lubricant.

28

Image 28
Contents SLR-DC Housing Canon EOS 7DTable of Contents Specifications Package Contents PreparationParts of the Housing Front View Side ViewBack View Initial Camera Setup Opening the HousingHousing Conversion Circuitry Setting the Conversion Circuitry Strobe ID SwitchUsing the Conversion Circuitry Set DS Substrobe to TTL mode Mode and Compensation ButtonsDS50 and DS125 Substrobe Compatibility Attaching the Flash Connection for External StrobesAttaching Camera to Housing Tray Installing Camera in HousingClosing the Housing Final CheckAttaching a Sync Cord to the Housing Turn Camera OnPreparing to Install Zoom Clamp & Gear Sleeve Zoom Clamps & Gear Sleeves Included with HousingInstalling the Zoom Clamp & Gear Sleeve On the Type 1 Lenses Type 1 Lenses Figure DInstalling the Zoom Clamp & Gear Sleeve On Type 2 Lenses Installing Zoom Clamp/Sleeve on Type 2 Lenses Manual FocusingInstalling the Port Port Seal Inside View Installing the Port To Remove PortLens Ports Attaching an Ikelite Strobe Arm to the Housing Handle Pre-Dive Your System UsageLubricants Troubleshooting Problem SolutionAny trapped moisture forming fog on the lens port Accessory Mounting Points Recommended AccessoriesEV-Controller Use Maintenance Control MaintenanceDiagram B Housing Maintenance Spare Parts Storing the HousingPhoto Tips Technical Support Photo TipsReturning Products For Service Limited WarrantyReturning Products for Service outside the United States Product Registration