Lacing film

Always scan the film with Emulsion up (towards camera lens). Focus will be compromised if film is laced emulsion down.

Ensure gate is in “Lace position” as shown in Fig 36. The Latch will push in to keep the gate in lace mode.

Lace Position

Fig 36

Loaded Position

1.Lace Film left to right missing the feed and take up sprockets and run the film straight from the Feed Compliance arm to the Take Up compliance arm via the PTR (Particle Transfer Roller) rollers to the take up film core. Lace as A or B wind depending on the wind direction of the supplied film rolls.(See Fig 34).

A or B status is set on the GUI (see page 7). Wind sufficient film onto the take-up film core to ensure a tight wrap.

Fig. 37 Initial lacing path

2Lace Take Up Sprocket. Rotate hold down clamp to lift

hold down rollers away from the sprocket as shown in Fig 38. Wrap film around sprocket as indicated, ensuring film perforations engage with sprocket teeth. When correctly wrapped rotate hold down clamp to lower rollers onto film.

3Lace film temporarily through gate, leaving sufficient loop for film motion.. The loop lengths should be set so they are just touching the skid plate area of the gate. (See Fig 37/38)

Fig 38 Sprocket lacing path

Issue 3

22

Image 22
Contents DiTTo Contents Business Users Declarations of ComplianceOther Countries outside the European Union DiTTo DiTTo data ScannerInstallation EMC Gland DiTTo ScannerPower up Virus ProtectionMain Scan ControlsCurrent timecode location of film on transport` Clip Display System StatusClip Entry Clip ManagementEDL and ALE Import to create clips Filename, Resolution, Exposure, Masking and Pre-scaleClip Editing Colour Indication of Clip Display Conform in progress File New Project File MenuGeneral View Menu View OptionsPlayback Viewer Tools MenuTools Playback Prescale Masking Exposure SCO Control If option is fittedTools Pre-Scale Control Tools Masking Control. See also Appendix Tools Exposure Control Tools Dmin Calibration Minimum Density settingSelect Auto Shading Correction Tools D/SCO Control If Option is fitted Settings Site General Settings Site EDL ListSettings Site File Name Transport Safety Interlock Description of Film TransportLacing film Lace PositionIssue Perf Gate Option S16mm Film Gate optionStop / Unload Pins DownPins UP Forward FWDGate Lacing Load Transport TensionFor safety information about this option refer to Appendix 35mm Keykode Reader OptionalTransport Film Path Rollers and Gate MaintenanceFilm Gate Removal Camera and illumination LensesParticle Transfer Rollers PTR’s Specification What is Intelligent Network Transfer? Do we have to record to the Local RAID?Cintel Inc Cintel Asia PacificTK1058-B3 LED Machine Status InformationMains Inlet M102750-AA1Cintel International Limited SOFTWARE/FIRMWARE LIC Ence Approximate File sizes for Colour DPX 10 bit LOG data scans For Colour Film settings Resolution 2K ColourFor B/W Film settings Resolution 2K Colour 6MB 38.4MB 25GB 135GB 1K data 1024 x 2MB 76.8MB 270GBSaftey Precautions and FCC Compliance Appendix MaskingAppendix Kodak Color Science Display ManagementWorkflow Enhancement Typical ‘Defect Map’