•1 Pulse Trigger
(At Time of
Negative polarity mode
Trigger*1
Positive polarity mode
About 1 ∝s
Exposure period*2 | Exposure period*2 | ||
|
|
|
|
External HD IN*1
External VD IN*1
About 1H
(Internal VD)
VIDEO INDEX
Video output
525H | (Partial scanning OFF) | The internal VD falling edge is within the exposure |
175H | (Partial scanning ON) | period and thus video is not output. *3 |
*1: Externally input signal
*2: Exposure time is determined by the setting of the MODE SELECT switch. Refer to page 10.
*3: Video is output at the falling edge of the internal VD following completion of the exposure period.
The video and the VIDEO INDEX have a paired relationship.
NOTE
When the next trigger is input before completion of the output of the video corresponding to the trigger, there will be an effect on the video.
•1 Pulse Width Trigger SYNC-RESET Picture Output Timing
Negative polarity mode
Trigger*1
Positive polarity mode
About 1∝s | About 7∝s | |||||
|
|
|
|
|
|
|
Exposure period*2
Exposure completion
0to 1H
VD OUT*3
Video output
VIDEO INDEX
525H (Partial scanning OFF)
175H (Partial scanning ON)
*1: Externally input signal
*2: Exposure time = Trigger pulse width + 6 ∝s
(Valid trigger pulse width is 2 ∝s or greater for external trigger shutter operation.)
*3: VD is generated after 0 to 1H following the completion of the exposure period and the video is synchronized to this and output.
NOTE
When the next trigger is input before completion of the output of the video corresponding to the trigger, there will be an effect on the video.
13