Toshiba CSGX36BC3, CSGS15BC23, CSGS20BC2, CSGV90BC3, CSGU15BC18 instruction manual Bottom

Page 50

Machine externals specification]

(1)

Dimensions

44mm(W) x 29mm(H) x 70mm(D) (Not including protrusion)

(2)

Mass

Approximately 120g

(3)

Lens mount

C-mount

Notes on combination of C-mount lens:

-Depending on the lens you use, the performance of the camera may not be brought out fully due to the deterioration in resolution and brightness in the peripheral area, occurrence of a ghost, aberration and others. When you check the combination between the lens and camera, be sure to use the lens you actually use. As for the C-mount lens used combining this camera, the projection distance from bottom of the screw should use 9.4mm or less.

 

 

Bottom of

C-mount lens

 

the screw

 

 

 

 

 

 

 

 

 

 

9.4mm or less

 

 

 

(4) Flange back

it is not possible to adjust it.

(5) Camera body grounding: insulation status

Conductive between circuit GND and camera body

Operating Ambient conditions

(1) Ambient conditions

 

- Performance assurance

 

Temperature

0 to 40° C

Humidity

10 to 90% (no condensation)

- Operating assurance

 

Temperature

-5 to 45° C

Humidity

90% or less (no condensation)

- Storage assurance

 

Temperature

-20 to 60° C

Humidity

90% or less (no condensation)

(2) EMC conditions

 

- EMI (Electro-Magnetic interference)

EN61000-6-4 conformity

 

FCC part15 Subpart B class A conformity

- EMS (Electro-Magnetic susceptibility)

EN61000-6-2 conformity

Notes on Conformity of the EMC:

-About the conformity of the EMC standard of this machine, it has guaranteed in the conditions combined with the option part of 4th clause.

When used combining parts other than specification of our company, I ask you to have final EMC conformity checked of a visitor with a machine and the whole equipment.

14

D4153660A

Image 50
Contents CSGV90BC3 CSGX36BC3 CSGS20BC2 CSGU15BC18 CSGS15BC23 Explanation of Safety Symbols Description Safety PrecautionsDefinition of Safety Signs Description Use the specified voltage General HandingDo not place anything on the equipment When performing connection, turn off power Avoid giving a strong shock against the camera bodyCases for Indemnity Limited Warranty Environmental operating conditions MaintenanceHandle carefully Check a combination with the lensFollowing information is only for EU-member states Others Features OverviewConfiguration Optional partExplanation rear panel LED2Connection Functions CSGV90BC3 CSGX36BC3 CSGS20BC2 CSGU15BC18 CSGS15BC23Exposure time depends on the normal shutter speed setting Minimum unit size Timing chart Expose GbE busTrigin Troubleshooting Internal sync signal specification SpecificationsElectrical specification [Electronic shutter specification] [Trigger signal specification]Output signal specification Interface specification[Machine externals specification] [Operating Ambient conditions][Typical spectral response] CSGU15BC18 CSGS15BC23 Outline Drawing D4153659A D4153659A Distributor CSGV90CC3 CSGX36CC3 CSGS20CC2 CSGU15CC18 Prohibited General Handing When performing connection, turn off power Cases for Indemnity Limited Warranty Handle carefully Following information is only for EU-member states 有毒有害物质或元素 部件名称 ( Pb) ( Hg) ( Cd) 六价铬 多溴联苯 多溴二苯醚 Color processing High-speed draft readout mode Trigin Exposeout Connection GVSPPIXBAYRG8 GVSPPIXBAYGB8 34fps 46fps Minimum unit size 160 x CSGV90CC3 CSGV90CC3 CSGX36CC3 Troubleshooting 1700 lx 2400 lx 1400 lx 1000 lx Standard subject illuminance Base clock frequency Maximum length of cable is 40m Bottom Responce Relative 400 450 500 550 600 650 700 Wave Lengthnm CSGU15CC18 Outline Drawing D4153660A D4153660A Distributor