Tyco ADC 660P instruction manual Camera As Video OUT Camera Bs Video OUT

Page 12

Hi-Res. B/W camera instruction manual

ADC 660N and ADC 660P

_________________________________

1.While observing the video output signals from both cameras on an oscilloscope, turn camera A's V-phase control (on back of camera) until vertical sync from both cameras is in phase.

2.If camera A's adjustment range is insufficient, adjust camera B's V- phase control in the opposite direction to camera A until they are in phase.

3.If these adjustments do not bring vertical sync from both cameras in phase, recheck the polarity of the power supply connections.

Camera A's VIDEO OUT

Camera B's VIDEO OUT

Should be in phase

If an oscilloscope is not available, a less accurate adjustment can be made by observing the monitor and adjusting the V-phase control potentiometer until no roll occurs on the monitor when switching back and forth between cameras A and B.

12

Image 12
Contents ADC 660N ADC 660P Equipment Modification Caution Page Do not attempt to disassemble the camera Never point the camera toward the sunUse a 24V AC / 12V DC class 2 LPS supply only ADC 660N and ADC 660P Connectors and Controls Video Output Connector BNC Video Output Connector BNC Power Input Connector screw terminalAuto Iris Lens Connector for Video Drive Lens Auto Iris Lens Connector for DC Drive LensBLC Backlight Compensation ON/OFF Switch ALC/ELC Select Switch EE/ELC is on ALC/AI is OFF AGC ON/OFF Switch INT/LL Switch LL is on INT is OFFFL on Switch Flickerless ON/OFF Phase Adjustment PotentiometerCamera As Video OUT Camera Bs Video OUT ALC Level Adjustment Potentiometer for DC Drive Lens Power Indicator LED Backfocus Adjustment ScrewADC 660N and ADC 660P Mount Adaptor Ring CCD Dust Protective CapCamera Mount Hole Camera Mount Base One monitor system with two or more cameras III. Dimensions IV. Specifications