iOptron 7200, 7201 Balancing the Payload, Connecting Cables, Setting Hand Controller

Page 16

STEP 6.Balancing the Payload

After attaching the scope and accessories, the mount head assembly must be balanced in both the R.A. and DEC axes to ensure minimum stress on the mount driving mechanism.

WARNING: The telescope may swing freely when the R.A. or DEC Gear Switch is disengaged. Always hold on to the telescope assembly before releasing the Gear Switches

to prevent it from swinging, which can cause personal injury and/or equipment damage.

The CEM gear system utilizes a magnetic force system

 

 

 

for optimal gear meshing. Fully turn the Gear Switch clockwise

 

 

 

to disengage the worm from the worm wheel. Turn the Gear

 

 

 

Switch counterclockwise to engage the worm to worm wheel,

 

 

 

 

Gear switch

 

as indicated on the mount. There is NO state between

 

 

 

 

 

 

Engaged and Disengaged. Setting the Gear Switch in

 

 

 

between states may damage the worm or worm wheel.

 

 

 

WARNING: The balancing process MUST be done

 

 

 

with Gear Switch at the Disengaged position!

 

 

 

Otherwise it might damage the worm system.

 

Figure 19. Gear switches

With the corresponding Gear Switch disengaged,

 

 

 

 

 

 

 

balance the assembly in R.A. axis by moving CW along its shaft. Balance in DEC axis by moving the scope with accessories back and forth in the mount saddle or within the scope mounting rings.

Only balance one axis at a time and start with the DEC axis first. Double check the mount to make sure both the R.A. and DEC axes are balanced.

Return the mount to the Zero Position after balancing; i.e., the CW Shaft points to ground, and the telescope tip is at its highest position.

Set both Gear Switches to engaged positions after balancing the mount. To make sure the gears are meshed properly, gently turn the Gear Switch counterclockwise all the way until you feel the resistance, but not over tightening. You may back out 1//8 turn if the gear is not moving smoothly.

STEP 7. Connecting Cables

 

Plug in a 12V DC power supply to the DC12V POWER

 

socket. Connect the Go2Nova® 8407 Hand Controller to the

 

HBX port on the mount side panel.

Figure 20. Connecting the cables

STEP 8. Setting Hand Controller

The CEM60 mount is equipped with a GPS receiver, which will receive the time, longitude and latitude information from satellites after the link is established. However, there are still some parameters which need to be entered to reflect your location, such as time zone info and daylight saving time. The information will be stored inside the hand controller memory along with longitude and latitude coordinates until they need to be changed.

A clear sky and open space outside is needed for the GPS to establish its link with the satellites. The GPS is installed on the side of the mount with a black plastic cover. If it has difficulty to receive the GPS signal, you may turn the mount head to the side of the mount to clear the space on top of it.

To set up the controller, press MENU =>“Settings”:

16

Image 16
Contents IOptron CEM60 Center-Balanced Equatorial Mount Page Table of Content Ioptron TWO Year TELESCOPE, MOUNT, and Controller Warranty Features CEM60 OverviewParts List1 CEM60 TermsAssembly Terms CEM60 Mount PortsCEM60 Gear Switches CEM60 Cable ManagementGo2Nova 8407 Hand Controller Key DescriptionLCD Screen Serial port pin out on an 8407 hand controllerPage CEM60Mount Assembly CEM60Mount AssemblyIntroduction Removing the Mount from the Carrying Case Attaching the MountSetting the Latitude Installing the Counterweight CW ShaftTilt the counterweight shaft for low Installing the CounterweightsSetting Hand Controller Connecting CablesBalancing the Payload Press Enter and select Set Time & Site Set Local TimeSet Observation Site Coordinates Performing Polar AlignmentQuick Polar Alignment BrightStar Polar Alignment Returning Mount to Zero PositionZero position Setting the Mount and Performing Polar Alignment Getting StartedManual Operation of the Mount One Star AlignmentStar Identification Function Turning Off the MountPutting the Mount Back into the Carrying Case Gear system for transportationComplete Functions of Go2Nova 8407Hand Controller Select and SlewSync to Target AlignDisplay Axes Error One Star AlignmentSolar System Align Multi-Star AlignSettings Set Time & SiteSet Beep Set DisplayElectric Focuser PEC Option Telescope MotionEnter a New Comet Edit User ObjectsEnter Other Objects or Observation List Firmware Information Goto Zero PositionMaintenance and Servicing MaintenanceIOptron Customer Service Battery Replacement and Disposal InstructionsAppendix A. Technical Specifications PECAppendix B. Go2Nova 8407HC Menu Structure MenuPage Page Appendix C. Firmware Upgrade Appendix D. Computer Control a CEM60 Mount Appendix E. Go2NovaStar List Messier CatalogNamed Star List Modern Constellations Deep Sky Object List Double Star List SAO Atik Ioptron TWO Year TELESCOPE, MOUNT, and Controller Warranty