iOptron 7201, 7200 Settings, Set Time & Site, Set Beep, Set Display, Set Guider Rate

Page 27

5.4. Settings

5.4.1. Set Time & Site

Refer to STEP 8 in Section 3.2.

5.4.2. Set Beep

The Hand Controller allows a user to turn off the beep partially, or even go to the silent mode by press “MENU =>Settings =>Set Beep”,

Set Up Time and Site

Set Beep

Set Display

Set Guiding Rate

Set Tracking Rate

Set Parking Position

Meridian Treatment

Tracking Below Horizon

Select one of three available modes:

"Always On” – a beep will be heard on each button operation or mount movement;

On but Keyboard” – a beep will be heard only when the mount slewing to the object or there is a waning message; or

Always Off” – all the sound will be turned off, including SUN wrning message.

5.4.3. Set Display

Press “MENU =>Settings =>Set Display”,

Set Up Time and Site

Set Beep

Set Display

Set Guiding Rate

Set Tracking Rate

Set Parking Position

Meridian Treatment

Tracking Below Horizon

Use the arrow keys to adjust LCD display contrast, LCD backlight intensity and keypads backlight Intensity.

5.4.4. Set Guider Rate

This is an advanced function for autoguiding when a guiding camera is equipped either via a Guide Port or an ASCOM protocol. Before autoguiding, align the polar axis carefully. Select a proper guiding speed. The suppositional guiding speed can be selected from ±0.10X to ±0.80X. Follow the autoguiding software for detailed operation.

Figure 26. Guide port pinout

27

Image 27
Contents IOptron CEM60 Center-Balanced Equatorial Mount Page Table of Content Ioptron TWO Year TELESCOPE, MOUNT, and Controller Warranty CEM60 Overview FeaturesCEM60 Terms Parts List1CEM60 Mount Ports Assembly TermsCEM60 Cable Management CEM60 Gear SwitchesKey Description Go2Nova 8407 Hand ControllerSerial port pin out on an 8407 hand controller LCD ScreenPage CEM60Mount Assembly CEM60Mount AssemblyIntroduction Attaching the Mount Removing the Mount from the Carrying CaseInstalling the Counterweight CW Shaft Setting the LatitudeInstalling the Counterweights Tilt the counterweight shaft for lowConnecting Cables Setting Hand ControllerBalancing the Payload Set Local Time Press Enter and select Set Time & SitePerforming Polar Alignment Set Observation Site CoordinatesQuick Polar Alignment Returning Mount to Zero Position BrightStar Polar AlignmentZero position One Star Alignment Setting the Mount and Performing Polar AlignmentGetting Started Manual Operation of the MountGear system for transportation Star Identification FunctionTurning Off the Mount Putting the Mount Back into the Carrying CaseSelect and Slew Complete Functions of Go2Nova 8407Hand ControllerAlign Sync to TargetMulti-Star Align Display Axes ErrorOne Star Alignment Solar System AlignSet Display SettingsSet Time & Site Set BeepElectric Focuser Telescope Motion PEC OptionEdit User Objects Enter a New CometEnter Other Objects or Observation List Goto Zero Position Firmware InformationBattery Replacement and Disposal Instructions Maintenance and ServicingMaintenance IOptron Customer ServicePEC Appendix A. Technical SpecificationsMenu Appendix B. Go2Nova 8407HC Menu StructurePage Page Appendix C. Firmware Upgrade Appendix D. Computer Control a CEM60 Mount Messier Catalog Appendix E. Go2NovaStar ListNamed Star List Modern Constellations Deep Sky Object List Double Star List SAO Atik Ioptron TWO Year TELESCOPE, MOUNT, and Controller Warranty