GX1660 User Manual |
SYNC OUTPUTS (1 to 4)
These signals are optically isolated and require the user to provide a high voltage level (USER VCC) and signal common (USER GROUND). USER VCC can be from 5V to 24V. ICC is a function of USER VCC and load resistor R. An example of the functional circuit is indicated in the following diagram.
3.3V CAMERA LOGIC SIGNAL
IF = 5mA
442R
100K
1
2
16
15
CAMERA | USER TRIGGER | |||||
CIRCUIT | CIRCUIT | |||||
|
|
| 5V TO 24V | |||
|
|
| ||||
PIN 10. USER VCC |
|
|
|
|
|
|
|
|
|
|
|
|
SYNC OUT
R
V LOAD
CAMERA
LOGIC SIGNAL
SYNC OUT
SIGNAL
T3
T1
T2 | T4 |
Various USER VCC values and load values for the above circuit are indicated in the following table:
USER | USER | R | V LOAD | R POWER | T1 | T2 | T3 | T4 |
VCC | ICC | LOAD |
| DISSIPATION |
|
|
|
|
5V | 8mA | 500 | 4.1V | 32mW | 1.5µs | 6.5µs | 2µs | 14µs |
|
|
|
|
|
|
|
|
|
5V | 4.8mA | 1K | 4.8V | 23mW | 1.5µs | 5µs | 17µs | 40µs |
|
|
|
|
|
|
|
|
|
12V | 9.2mA | 1.2K | 11.2V | 101mW | 1.5µs | 11.2µs | 2µs | 20µs |
|
|
|
|
|
|
|
|
|
12V | 4.9mA | 2.4K | 11.8V | 58mW | 1.5µs | 8.5µs | 17µs | 55µs |
|
|
|
|
|
|
|
|
|
24V | 9.5mA | 2.4K | 23.2V | 217mW | 1.5µs | 22µs | 2µs | 37µs |
|
|
|
|
|
|
|
|
|
24V | 5mA | 4.8K | 23.8V | 120mW | 1.5µs | 12µs | 17µs | 105µs |
|
|
|
|
|
|
|
|
|
Allied Vision Technologies (Canada) Inc. | 8 |