Vivotek IP2121, IP2111 user manual General I/O terminal block

Page 10

General I/O terminal block

1

Å

DI+

INPUT

(Max. 50mA, 12VDC)

2

Å

DI-

INPUT

 

3

Å

SW_COMMON

OUTPUT

(short with NC at initial state)

4

Å

SW_NOPEN

OUTPUT

(Max. 1A, 24VDC or 0.5A, 125VAC)

5

Å

RS485 B

 

(inverting)

6

Å

RS485 A

 

(non-inverting)

NetworKam provides a very flexible general I/O interface to combine with the user’s security devices such as sensors, alarms, lighting or door locks. The general I/O terminal block has six pins for device control. These pins can be divided into two categories based on their functions, including RS485 and digital inputs and outputs.

If the device connected to COM has an RS485 interface, wire two control lines to pin 5 and pin 6. After switching to RS485 on the configuration page, the PT control commands will be directed through pin 5 and pin 6. If the distance from the controlled device is too far to allow accurate function, an external power source may be used to pull high the RS485 signal.

NetworKam provides one digital input and one relay switch. Pin 1 and pin 2 can be connected to external sensor and the state of voltage will be monitored according to the programmed scripts in configuration. The relay switch can be used to turn on or off external devices.

9

www.vivotek.com

T: 886-2-22404099

F: 886-2-22404097

Image 10 Contents
NetworKam Before You Use Table of Contents Web URL commands of NetworKam Appendix Package Contents 886-2-22404099 886-2-22404097 Ethernet 10/100 socket Physical DescriptionRear Panel COM portGeneral I/O terminal block Status LEDs Power adapter Restore buttonAuto Iris Lens Connector How to Install Ethernet Environment Hardware installationCable connection Power on Software configuration Easy way with installer program886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 Manual way with existing programs First access to NetworKam 886-2-22404099 886-2-22404097 Modem Environment Cable connection Install a new modem 886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 Setup a new connection 886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 First access to NetworKam 886-2-22404099 886-2-22404097 How to Use Authentication 886-2-22404099 886-2-22404097 Primary user’s capability Main screen with camera viewVideo quality selection Video size selection Pan/Tilt positioning device control System configuration System parameters User group administration Network settings 886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 Video parameters 886-2-22404099 886-2-22404097 Camera positioning device configuration 886-2-22404099 886-2-22404097 Modem and dial-up settings 886-2-22404099 886-2-22404097 Application 886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 Demonstration account settings Homepage layout settings One-shot fast configuration via FTP Read only string Text mode or 1 for image mode For fuchsia, 12 for silver, 13 for red, 14 for blue Standard IP format or string shorter than 40 characters Video Or RS485 Alert Demo Alarm settings Advanced functionsViewing system log Restore factory default settingsClear data path for proprietary commands Viewing system parametersViewing and downloading the stored snapshots Downloading the update snapshotsUploading snapshots periodically to an external FTP server Customizing images of homepageUploading the configuration file Software revision upgradeEasy way via Upgrade Wizard Stop information dumping System core debuggingMonitor changed status of digital inputs Query status of digital inputsReset system Skip installation at next bootReset network for new settings Set digital outputsCapture update Snapshot of video channel URL commands of NetworKamDisplay images 886-2-22404099 886-2-22404097 Move positioning device in PT direction Clear data mode serial port driverGet stored snapshots from Flash memory Drive digital outputsRestart system URL System resource URL System configuration URL General format of command URLUsers configuration URL Network configuration URL Video configuration URL Image quality configuration URL Camera control configuration URLCamera custom command configuration URL Modem Configuration URLApplication configuration URL Motion detection configuration URLDemo configuration URL Homepage layout configuration URLPost procedure AppendixFrequently asked questions 886-2-22404099 886-2-22404097 886-2-22404099 886-2-22404097 Technical specifications NetworkingElectromagnetic Compatibility EMC