Oce North America 500XL manual Electronic, Optical and Mechanical Failures

Page 18

LightJet 500XL Maintenance Guide ×

Other power-up problems include:

§The LightJet® 500XL takes longer than 15 minutes to power up. This indicates a servo laser test failure. The LightJet® Explorer Optical Motors Window displays which laser failed the test in the attenuator fields.

§If the power circuit breaker switch and the control panel are on, but the blue laser blower, exhaust cooling fan and cardcage cooling fans are off, contact Océ.

Electronic, Optical and Mechanical Failures

This section provides a list of error conditions for the LightJet® 500XL. When an error occurs, the control panel displays:

Errors Encountered

<ENTER to View, ESC to Clear>

1.Press ENTER to display the error (ESC will clear the error buffer without displaying the error).

2.After viewing the error, press the SETUP, MEDIA or ON LINE keys to clear the error buffer. Note that this clears the error buffer, but does not correct the cause of the error.

3.Use the recommended recovery methods described below to troubleshoot the error. If the printer does not allow you to initiate the recovery process, power down and restart the printer, then continue the process. Wait at least 15 seconds between powering off and on. Rapid power cycling can harm the electronics.

If you are unable to resolve the problem, contact Océ (see “Product Support, Documentation and Service on page ii).

Error 01 – End of Roll During Load

Possible

Loaded media is less than 125” in length. Loading the machine requires a

Cause:

minimum of 125” of media.

 

 

Recovery

Select Set Up/Motor Control/All Motors Reverse. Retract 135 inches of

Method:

media.

 

 

3-2

see copyright, disclosure, use and duplication information on pg ii

48058-A

Image 18
Contents Océ ½LightJet 500XL Maintenance Guide Océ Display Graphics Systems ALL Rights ReservedTable of Contents List of TablesProduct Support, Documentation and Service CopyrightDocument History Serial number of your LightJet 500XL Product Compliance and Standards Electromagnetic CompatibilitySafety of Laser Products EN60825-1 This page Intentionally Left Blank LightJet 500XL Safety Information Important Safety Information for Maintenance PersonnelEnd of Section Preventative Maintenance Service Visits Cleaning Your LightJet 500XLOutput Pinch Rollers Maintenance Activity Weekly Mths AnnuallyMedia Load and Unload Area DrumLight Shield Intake Air FilterCoalescing Filter Clearing Media Jams Power Distribution ChecklistChecking the Cooling System Load JamAdvance Jam Power-up Failures Retrieving the LightJet LogError 01 End of Roll During Load Electronic, Optical and Mechanical FailuresError 04 Infeed Timeout Fault Error 02 Media Seating FailedError 03 Excessive Media Slip Error 05 Media Guide Location UnknownError 10 Outfeed Timeout Fault Error 06 Micropositioner Location UnknownError 07 Media Guide Stuck at Home Communication FailuresUndesirable Artifacts on Media This page Intentionally Left Blank