Oce North America 500XL manual Retrieving the LightJet Log, Power-up Failures

Page 17

Ø Troubleshooting

3Troubleshooting

Problems with the LightJet® 500XL generally fall into four categories:

§Power-up Failures

§Electronic, Optical and Mechanical Failures

§Communication Failures

§Undesirable Artifacts on Media

Retrieving the LightJet® Log

LightJet Explorer maintains a log of the actions performed by the LightJet 500XL. This is an excellent diagnostic tool and Océ service representatives may request that you refer to or send in a copy of the log to assist them during a support call. To retrieve the log:

1.In LightJet Explorer, select Utilities/Retrieve Log.

2.The log can then be saved as a text file by selecting File/Save As.

Power-up Failures

Power problems that can occur include:

§The power circuit breaker switch is on, but nothing operates.

§The power circuit breaker switch is on and the air blower, outfeed exhaust cooling fan and cardcage cooling fans are operating, but the control panel is off (no display or backlight indicator).

If either of these conditions occur:

1.Check that the power circuit breaker switch is operating by turning it off and back on once. Wait at least 15 seconds between cycles.

2.Check that the power cord is properly connected to both the wall outlet and the LightJet® 500XL.

3.Check that the dedicated circuit breaker for the LightJet® 500XL in the building’s main circuit breaker panel is on.

4.If you don’t find the problem, contact Océ (see “Product Support, Documentation and Service” on page ii).

48058-A

see copyright, disclosure, use and duplication information on pg ii

3-1

Image 17
Contents Océ ½LightJet 500XL Maintenance Guide ALL Rights Reserved Océ Display Graphics SystemsList of Tables Table of ContentsDocument History Product Support, Documentation and ServiceCopyright Serial number of your LightJet 500XL Electromagnetic Compatibility Product Compliance and StandardsSafety of Laser Products EN60825-1 This page Intentionally Left Blank Important Safety Information for Maintenance Personnel LightJet 500XL Safety InformationEnd of Section Cleaning Your LightJet 500XL Preventative Maintenance Service VisitsMedia Load and Unload Area Maintenance Activity Weekly Mths AnnuallyOutput Pinch Rollers DrumIntake Air Filter Light ShieldCoalescing Filter Checking the Cooling System Power Distribution ChecklistClearing Media Jams Load JamAdvance Jam Retrieving the LightJet Log Power-up FailuresElectronic, Optical and Mechanical Failures Error 01 End of Roll During LoadError 03 Excessive Media Slip Error 02 Media Seating FailedError 04 Infeed Timeout Fault Error 05 Media Guide Location UnknownError 07 Media Guide Stuck at Home Error 06 Micropositioner Location UnknownError 10 Outfeed Timeout Fault Communication FailuresUndesirable Artifacts on Media This page Intentionally Left Blank