LightJet 500XL Maintenance Guide ×
Error 06 – Micropositioner Location Unknown
Possible | Micropositioner has lost servo. | |
Cause: |
| |
Recovery | Select Media/Cut and Unload. If problem persists, contact Océ. | |
Method: |
| |
Error 07 – Media Guide Stuck at Home | ||
|
| |
Possible | A) Media guides are stuck in their parked position. | |
Causes: | B) Mechanical component failure. | |
|
| |
Recovery | A) Select Media/Cut and Unload. Inspect media guides. Clear physical | |
obstruction if present. | ||
Methods: | ||
B) Contact Océ. | ||
| ||
|
| |
Error 10 – Outfeed Timeout Fault | ||
|
| |
Possible | The | |
Cause: |
| |
Recovery | Select Set Up/Motor Control/All Motors Reverse. Retract 150 inches of media. | |
Method: | If error persists, contact Océ. | |
|
|
Communication Failures
Problems that prevent proper communication between the LightJet® 500XL and the host computer can cause total loss of communication, prevent certain functions, or corrupt the data used to generate the image. The LightJet® 500XL cannot detect:
§Whether the host computer is unable to generate the proper commands.
§Some cases of data corruption.1
§When a SCSI cable is bad or disconnected.
§When the wrong SCSI ID has been selected.2
Notes:
1The LightJet 500XL can detect some, but not all, types of data corruption.
2The LightJet 500XL is shipped from the factory with the SCSI ID set to 6 (binary 110).