Jenn-Air W10349768A Electrical Requirements Canada Only, Gas Supply Requirements, Type of Gas

Page 7

Electrical Requirements - Canada Only

WARNING

Electrical Shock Hazard

Electrically ground range.

Failure to do so can result in death, fire, or electrical shock.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path and wire gauge are in accordance with local codes.

Be sure that the electrical connection and wire size are adequate and in conformance with the CSA Standard C22.1, Canadian Electrical Code, Part 1 - latest edition, and all local codes and ordinances.

A copy of the above code standards can be obtained from:

Canadian Standards Association

178 Rexdale Blvd.

Toronto, ON M9W 1R3 CANADA

Check with a qualified electrical installer if you are not sure the range is properly grounded.

When a 4-wire, single phase 250 volt, 60 Hz., AC only electrical supply is available, a 40-amp minimum circuit protection is required on 30" (76.2 cm) and 36" (91.4 cm) ranges and a 50-amp minimum circuit protections is required on 48" (121.9 cm) ranges, fused on both sides of the line.

A time-delay fuse or circuit breaker is recommended.

This range is equipped with a CSA International Certified Power Cord intended to be plugged into a standard 14-50R wall receptacle. Be sure the wall receptacle is within reach of range’s final location.

Do not use an extension cord.

Gas Supply Requirements

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure gas pressure does not exceed 14" (36 cm) water column.

Examples of a qualified person include:

licensed heating personnel,

authorized gas company personnel, and authorized service personnel.

Failure to do so can result in death, explosion, or fire.

Observe all governing codes and ordinances.

IMPORTANT: This installation must conform with all local codes and ordinances. In the absence of local codes, installation must conform with American National Standard, National Fuel Gas Code ANSI Z223.1/NFPA 54 - latest edition or CAN/CGA B149 - latest edition.

IMPORTANT: Range cooktop must be connected to a regulated gas supply.

IMPORTANT: Leak testing of the range cooktop must be conducted according to the manufacturer’s instructions.

Type of Gas

Natural Gas:

This range is design-certified by CSA International for use with Natural gas or, after proper conversion, for use with LP gas.

This range is factory set for use with Natural gas. The model/ serial rating plate located under the console on the right-hand side has information on the types of gas that can be used. If the types of gas listed do not include the type of gas available, check with the local gas supplier.

LP Gas conversion:

Conversion must be done by a qualified service technician.

No attempt shall be made to convert the range cooktop from the gas specified on the model/serial rating plate for use with a different gas without consulting the serving gas supplier. To convert to LP gas, use the LP gas conversion kit provided with your range and see the “Gas Conversions” section. The parts for this kit are in the literature package supplied with the range.

7

Image 7
Contents Commercial Style Dual Fuel Convection Ranges Installation InstructionsYour safety and the safety of others are very important Range SafetyTools and Parts Installation RequirementsLocation Requirements Mobile Home Additional Installation RequirementsProduct Dimensions 30 76.2 cm models Mobile home installations require48 121.9 cm models 36 91.4 cm models Cabinet DimensionsElectrical Connection If connecting to a 4-wire systemIf connecting to a 3-wire system Electrical Requirements U.S.A. OnlyNatural Gas Electrical Requirements Canada OnlyGas Supply Requirements Type of GasGas Pressure Regulator Gas Supply Pressure TestingUnpack Range Gas Supply LineMeasurement C Install Optional BackguardInstall Anti-Tip Bracket Measurement B48 121.9 cm Models Electrical Connection U.S.A. Only30 76.2 cm and 36 91.4 cm Models Wall MountingGround-link screw Ground link bent away from range Wire connection Power supply cordComplete Connection Make Gas ConnectionVerify Anti-Tip Bracket Location Level RangeElectronic Ignition System Install GriddleReinstall Kick Plate LP Gas Conversion Complete InstallationIf you need Assistance or Service GAS ConversionsBurner orifice spud Gas Supply Pressure TestingTo Convert Gas Pressure Regulator To Convert Surface BurnersNatural Gas Conversion Complete InstallationSmall Burner A. Burner cap Strip Circuits Cooktop SchematicsBurner Cooktop SW4 SW5 SW6 Atlas Board HMI Keyboard LCD Wiring DiagramsAtlas Board HMI Keyboard LCD 48 121.9 cm Oven Schematic for Jdrp and Yjdrp ModelsVotre sécurité et celle des autres est très importante Sécurité DE LA CuisinièreOutils et pièces Exigences D’INSTALLATIONDimensions du produit Modèles de 30 76,2 cm Exigences d’emplacementConversion pour utilisation en haute altitude Modèles de 36 91,4 cm Dimensions du placardSpécifications de lalimentation en gaz Spécifications de l’installation électriqueRemarque Dégagements minimums Débit thermique des brûleurs Altitude Type de gazCanalisation de gaz DétendeurDéballage de la cuisinière Instructions D’INSTALLATIONInstallation du dosseret facultatif Installation de la bride antibasculementMontage au mur Raccordement au gazMesure C Montage au plancherSystème dallumage électronique Vérification de lemplacement de la bride AntibasculementInstallation de la plaque à frire Réglage de laplomb de la cuisinièreHauteur de flamme Réglage de la taille des flammesAllumage initial et réglages des flammes de gaz Si les brûleurs ne sallument pas correctementContrôle du fonctionnement du/des fours Réinstallation du garde-piedsAchever linstallation Si vous avez besoin d’assistance ou de serviceTest de pressurisation de la canalisation de gaz Conversions Pour Changement DE GAZConversion pour lalimentation au propane Conversion du détendeurConversion des brûleurs de surface Achever l’installationGicleur de brûleur Conversion pour lalimentation au gaz naturel Schémas des circuits Table de cuisson à 4 brûleurs Schémas de la table de cuissonSchémas de câblage SMPS14VCC45WLampeshalogènes ORVENTLATEUR~ DEVentilaturde Refroidissmente Duloquet

W10349768A specifications

The Jenn-Air W10349768A is a premium range hood designed to enhance the functionality and aesthetic appeal of modern kitchens. With a blend of advanced technology and elegant design, this model meets the needs of culinary enthusiasts and homeowners alike.

One of the key features of the W10349768A is its powerful ventilation system. Equipped with a robust motor, it offers multiple fan speeds to efficiently eliminate smoke, odors, and airborne grease created during cooking. Its high airflow capacity ensures that even the most intense cooking sessions leave your kitchen fresh and clean. This range hood is particularly effective in larger kitchen spaces, making it a versatile choice for various layouts.

The design of the W10349768A prioritizes aesthetics as much as functionality. The sleek stainless steel finish not only provides a modern look but is also easy to clean and maintain, ensuring that it remains a focal point in your kitchen for years to come. The unit's minimalist design integrates seamlessly with a wide range of kitchen styles while providing the durability expected from a Jenn-Air product.

In terms of technology, the W10349768A features advanced noise reduction capabilities. It operates at a lower decibel level compared to traditional range hoods, making it ideal for open-concept living spaces where noise can disrupt conversations or the enjoyment of family gatherings. This attention to noise levels reflects Jenn-Air’s commitment to creating a pleasant cooking environment.

The range hood also comes with convenient features like adjustable lighting. Equipped with high-quality LED lights, it provides ample illumination for the cooking surface below, enhancing visibility while also being energy-efficient. This allows home cooks to monitor their meals effortlessly and adds an inviting ambiance to the kitchen.

Another notable characteristic of the W10349768A is its easy-to-use controls. The intuitive interface allows users to adjust fan speeds and lighting with just a touch, making it accessible for everyone in the household. Additionally, the dishwasher-safe filters ensure that maintenance is straightforward, promoting hygiene and performance.

All of these features make the Jenn-Air W10349768A a top choice for those looking to blend performance with style in their kitchen. Its powerful ventilation, modern aesthetics, and user-friendly technology position it as an essential tool for any serious home chef. Whether you're sautéing, grilling, or baking, this range hood is designed to enhance your culinary experience while elevating the overall design of your kitchen space.