MENU SETTING |
|
| |
MOTION DETECT Screen |
| ||
Settings are executed about the motion detecting function that emits alarm signals when | |||
there exists any motion in the image. Alarm signals are output from the auxiliary terminals on | |||
the back. |
|
|
|
Item |
| Functions and set values | Initial value |
MODE | This sets ON/OFF of motion detecting function. | OFF | |
| OFF: | Motion detecting function does not work. |
|
| ON: | Motion detecting function works. |
|
LEVEL | This sets the level that detects motion. | NORMAL | |
| If the item MODE is set to OFF, “- - |
| |
| settings cannot be changed. |
| |
| To function with large signal level change…decrease the |
| |
| value |
|
|
| To function with small signal level change…increase the |
| |
| value |
|
|
| [Set values: |
| |
AREA EDIT | This sets the range in which the motion detecting function | – | |
| works. |
|
|
| ( Page 37) |
|
COMMUNICATION Screen |
| |
Settings are made for the control |
| |
If the setting is changed, be absolutely sure to switch on the power again. |
| |
Item | Functions and set values | Initial value |
STYLE | This sets a communication system according to the | P TO P |
| system used. |
|
| P TO P (Point to point) |
|
| This is set when a remote control unit controls a camera. |
|
| M.DROP |
|
| This is set when a remote control unit controls a plural |
|
| number of cameras. |
|
MACHINE ID | This is set when the STYLE item is set to M.DROP. This | – – – |
| is the number that identifies individual cameras in a group. |
|
| No proper function can be realized if an ID number is |
|
| repeated within a system. |
|
| A combined use with the |
|
| setting together with the video input number of the RM- |
|
| P2580. |
|
| If the item STYLE is set to P TO P, “- - |
|
| settings cannot be changed. |
|
| [Set values: 1 to 99] |
|
ALARM TIME This sets the output time of the alarm signal output of | 10s |
AUX terminal as well as “ALARM” display on the screen |
|
when motion is detected. |
|
If the item MODE is set to OFF, “- - |
|
settings cannot be changed. |
|
[Set values: OFF, 5s, 6s, 7s, 8s, 9s, 10s, 15s, 20s, 30s, |
|
1min] |
|
MEMO |
|
When the MODE item is set to OFF, only the alarm signal |
|
MAINTENANCE Screen | |
White spot compensation is performed. | |
Item | Functions and set values |
CCD SPOT | The white spots on the screen, which are characteristic |
| for CCDs can be reduced. |
Page 38 “White Spot Compensation”
Initial value –
| of the AUX terminal is output, and “ALARM” is not |
|
| displayed on the screen. |
|
DEMONSTRATION | This is used when checking and confirming the set motion | – |
| detecting function. The detection area is shown in gray. | |
|
| |
| ( Page 37) |
|
FACTORY SETTINGS Screen | |||
Set values are returned to initial values. | |||
Item |
| Functions and set values | |
FACTORY | The values set on the menu are returned to initial values. | ||
SETTINGS | CANCEL | : | No return to the initial value. |
| CLEAR | : | Returns set values except titles to the |
| (WITHOUT TITLE) |
| initial value. |
| CLEAR (ALL) | : | Returns all set values including titles |
|
|
| to the initial value. |
| Select respective set value and press the SET button. | ||
| Then, “DATA CLEARED” will appear for about 3 seconds. | ||
| Be sure not to switch off the power while the display is | ||
| still on. |
|
|
| MEMO |
|
|
| However, when making settings by means of transmitted | ||
| commands, the contents of the COMMUNICATION menu | ||