CONNECTION/INSTALLATION |
|
Installing the ferrite core |
|
To retain electromagnetic compatibility, use the ferrite cores provided when connecting to | |
the lens. |
|
| |
(or | |
ALC | Av Pk |
LEVEL | L H |
VIDEO |
|
DC |
|
MEMO
•If thin cables are used (i.e. with a high resistance), a significant voltage drop will occur when the unit is at its maximum power consumption. Either use a thick cable to restrict the voltage drop at the camera side to below 10%, or place the power supply near to the camera. If voltage drop occurs during operation, the performance will be unstable.
•Attach the cable conductors so that they do not come into contact with the drop prevention wires.
•Do not allow input from both a DC 12 V and AC 24 V power supply at the same time.
•When using a DC 12 V power supply, ensure that the polarities of the cable are correct.
•The AC 24 V power supply should conform to the following: Isolated power supply only
Ferrite core |
Wire clamp |
Notes: |
Install the ferrite cores within 50 mm of the |
core with the wire clamp provided.) |
Control signal cables
These cables should be connected only when it is required to control the camera using the
Genlock connection
With some systems, when the external sync signal is a composite video or black burst sig- nal genlocking by applying an external sync input requires the horizontal phase (H PHASE) and colour phase (SC COARSE) to be adjusted.
Connections on the back Power supply (DC 12 V or AC 24 V)
| + | - |
| 1 | 2 |
DC12V | AC24V | CLASS2 ONLY(U TYPE) ISOLATEDPOWER ONLY (E TYPE) |
|
| TX+ TX- RX+ RX- AUX GND |
|
| A B C D |
|
| Y/C OUT |
| SYNC IN | VIDEO OUT |
|
| SEE INST- |
| POWER | RUCTION |
| MANUAL |
Connect the DC 12 V or the AC 24 V power | |||||
supply to the DC 12V/AC 24V terminals. To | |||||
prevent connection errors or a | cable | ||||
disconnection, we recommend the use of lug | |||||
plates for the connections. |
|
| |||
The following table shows the connection | |||||
distances and connection cables provided | |||||
that | |||||
vinyl sheath cables) are used. |
|
| |||
Maximum extension | 100 m | 260 m | 410 m | 500 m | |
(reference) | |||||
|
|
|
| ||
Conductor | 1.0∅mm | 1.6∅mm | 2.0∅mm | 2.6∅mm | |
diameter | and more | and more | and more | and more |
|
| Connect to the other | MEMO |
A | TX+ | • Genlocking is not possible with a signal con- | |
B | TX- | side in pairs like this. | taining too much jitter, such as a VCR or |
|
|
| |
|
|
| videodisc playback signal. |
C | RX+ | Connect to the other | |
D | RX- | side in pairs like this. | • For details, consult a JVC authorized dealer. |