JVC KY-F560 Description of Terminals, Power Input Terminal Mini DIN 8 Pin Female

Page 11

Description of Terminals

Power Input Terminal (Mini DIN 8 Pin,

Female)

7

 

 

 

 

 

 

 

 

8

 

 

 

 

6

 

5

 

 

 

 

3

 

2

 

 

 

 

4

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

Pin No.

 

 

 

 

 

Signal

1

NC

 

2

GND

 

 

 

 

3

NC

 

4

NC

 

5

GND

 

6

+ 12 V Input

 

7

NC

 

 

 

 

8

+ 12 V Input

 

 

 

 

 

 

 

 

Lens Connection Terminal (Metal 12 Pin, Female)

 

 

9

10

1

 

 

 

8

 

2

7

 

 

3

 

 

6

 

4

 

 

12

5

11

 

 

 

 

 

 

 

 

 

Pin No.

 

 

 

Signal

1

 

LENS RET

2

 

NC

 

 

3

 

GND

 

 

4

 

LENS AUTO

5

 

IRIS CONTROL

6

 

+ 12 V Output

7

 

IRIS POSITION

8

 

IRIS A/R

 

9~12

 

NC

 

 

Remote Terminal (Mini DIN 6 Pin,

Female)

 

 

6

 

 

5

 

 

 

 

4

 

 

 

3

 

 

 

 

 

2

 

 

1

 

 

 

 

 

 

 

 

 

 

 

Pin No.

 

 

 

 

Signal

1

 

GND

 

2

 

OPERATE (L:ON)

 

 

 

 

3

 

GND

 

4

 

SID2(TX)

 

5

 

SID1(RX)

 

6

 

+ 9 V Output

Notes

Please consult your JVC-authorized dealer on connection of remote terminals.

Ensure to use cables that are shielded.

English

E-11

Image 11
Contents KY-F560 Genlock Port Cable LengthLens Video OUTSafety Precautions Contents Advanced Exposure Screen Setting Via the Menu ScreenGetting Started FeaturesPoints to Note During Use  Characteristic CCD Phenomena Precautions During Handling Camera Mounting Bracket Camera Mounting Screw Holes 20UNC Getting Started Part Names and Functions Front / BottomSET Set Button 18 ‘External Monitor Adjustment’Back Menu Menu Button$ Genlock in External Sync Signal Input Terminal Video OUT Video Signal Output Terminal@ Power Power Indicator Light # DC in Power Input TerminalRemote Terminal Mini DIN 6 Pin Female Power Input Terminal Mini DIN 8 Pin FemaleDescription of Terminals Lens Connection Terminal Metal 12 Pin, FemalePreparation Before Shooting Diagram below illustrates connection of a basic systemSync Signals Composite Video Signals or Black Burst SignalsApplied System Diagram below illustrates connection of an applied systemHole Preparation Before ShootingMounting the Lens White Marking Connect the end with Connecting the Power SupplyAA-P700 AC Adaptor AC 120Anti-rotation Hole Mounting ProceduresMounting the Camera Changing the Camera Mounting BracketSafety cable to Prevent Falling of Equipment Camera Head Precautions to Prevent Camera From FallingExternal Monitor Adjustment Setting and Adjustment During ShootingTo adjust, follow steps 3. ~10. above Back Focus Adjustment Power Zoom Lens Siemens Star Chart ObjectMenu SET Setting and Adjustment During ShootingWhite Balance Adjustment  Setting procedures for Auto White AUTO1,AUTO2Errorover Light Excessive Illumination Error DisplayNgobject Object Error Errorlow Light Insufficient IlluminationWhite Balance Screen White Shading AdjustmentMenu Screen Ance adjustment again Set value starts blinking and adjustment is possibleRefer to the monitor to adjust values for Levelr Levelg and Levelb using the / buttonsTion to the screen If black bands are visible use Various Modes of ShootingShooting the Computer Monitor Button UseSystem screen will be displayed Output of Negative ImageUse the / buttons to select SYSTEM.., then press Preparation How To Use  Detection of White SpotsVarious Modes of Shooting White Spot CorrectionDetecting Screen Detection Completed Screen Detection Error Screen White Spot Correction Messages Main Menu Setting Via the Menu ScreenFlow of Menu Screens Normal ScreenNormal Setting Procedures Setting Via the Menu ScreenStep Exposure ScreenAuto Advanced ShutterScan EEINormal Advanced Exposure Screen200 Auto White Balance ScreenLevelg PresetShading LOW Process 1/2 ScreenKnee Knee FunctionWhite Clip 108%Manual Process 2/2 ScreenOFF StandardFlarer StretchCompress FlareColour Matrix Adjust ScreenRotation Cyan Increase valueSystem Screen CancelMenu Screen Blinking File Manage Screen Display the File Manage screen  Save the set value Retrieve file  Reset the set valueENTER/SET FAR Connecting the Remote Control UnitOthers ConnectionMAX HI-RESO on ALC, ALC+EEI ALC/ALC+EEI Lolux ShutterSC Fine Zoom Focus HI-RESO White Shading Normal HI-RESO OFFOthers Connecting Optional Devices Installation of Option Card Compliance Range 2300 K 10000 K SpecificationsMANUAL, AUTO1, AUTO2, PRESET, FAW 166.8 12.4 Dimensional Drawing Unit mm