JVC KY-F560 Various Modes of Shooting, White Spot Correction, Preparation, Operation

Page 26

4. Various Modes of Shooting (continued)

White Spot Correction

As a peculiar common characteristic of CCD, white spots may appear on the screen when operated under high temperature.

This unit comes with a white spot correction feature to reduce this phenomenon.

How To Use

Detection of White Spots

The quantity and size of white spots differ with the temperature and shutter speed during use. Before using the white spot correction feature, it will thus be necessary to detect the position of the white spots under the conditions of use.

[ ]

 

 

Preparation

[

]

 

 

 

[MENU]

 

[SET]

Set the conditions of use (ambient temperature, shutter speed,

 

 

 

AW BARS

 

 

etc.) in this unit.

 

 

Turn on the power of the camera and leave it on for at least 2

MENU

SET

 

REMOTE

LENS

 

hours.

 

 

 

Close the lens iris to ensure that no light enters the CCD.

GENLOCK IN

VIDEO OUT

2. 3.

Blinking

 

 

 

 

 

- - - SYSTEM - - -

 

 

ASPECT RAT I O

4 : 3

 

 

 

NEGA T I VE

OF F

 

 

P I XE L COMPEN

CANCEL

 

 

 

H PHASE

0

 

 

 

SC COARSE

0

 

 

 

SC F I NE

0

 

 

 

PAGE BACK

 

 

 

 

 

 

 

 

“SYSTEM” Screen

4. 5.

Blinking

 

 

- - - SYSTEM - - -

 

 

ASPECT RAT I O

4 : 3

 

 

 

NEGA T I VE

OF F

 

 

P I XE L COMPEN

EXECUTE

 

 

 

 

 

 

H PHASE

0

 

 

 

SC COARSE

0

 

 

 

SC F I NE

0

 

 

 

PAGE BACK

 

 

 

 

 

 

 

 

 

Operation

1. Press the [MENU] button for 1-2 seconds.

The “MENU” screen will be displayed.

2. Use the [/] buttons to select “SYSTEM..”, then press the [SET] button.

The “SYSTEM” screen will be displayed.

3. Use the [/] buttons to select “PIXEL COMPEN”, then press the [SET] button.

The “CANCEL” value starts blinking and adjustment is pos- sible.

4. Use the [/] buttons to select “EXECUTE” and press the [SET] button to start the white spot detection.

Detection process may take a few minutes to complete.

5. Upon completing detection,“Detection Completed” screen will be displayed.

6. Turn on the power again.

Allow a 10 seconds interval after switching off the power be- fore turning on again.

When power is turned on, white spots will be corrected.

“SYSTEM” Screen

E-26

Image 26
Contents KY-F560 Video OUT Port Cable LengthLens GenlockSafety Precautions Contents Setting Via the Menu Screen Advanced Exposure ScreenFeatures Getting StartedPoints to Note During Use  Characteristic CCD Phenomena Precautions During Handling Front / Bottom Getting StartedPart Names and Functions Camera Mounting Bracket Camera Mounting Screw Holes 20UNCMenu Menu Button 18 ‘External Monitor Adjustment’Back SET Set Button# DC in Power Input Terminal Video OUT Video Signal Output Terminal@ Power Power Indicator Light $ Genlock in External Sync Signal Input TerminalLens Connection Terminal Metal 12 Pin, Female Power Input Terminal Mini DIN 8 Pin FemaleDescription of Terminals Remote Terminal Mini DIN 6 Pin FemaleBurst Signals Diagram below illustrates connection of a basic systemSync Signals Composite Video Signals or Black Preparation Before ShootingDiagram below illustrates connection of an applied system Applied SystemHole Preparation Before ShootingMounting the Lens AC 120 Connecting the Power SupplyAA-P700 AC Adaptor White Marking Connect the end withChanging the Camera Mounting Bracket Mounting ProceduresMounting the Camera Anti-rotation HolePrecautions to Prevent Camera From Falling Safety cable to Prevent Falling of Equipment Camera HeadSetting and Adjustment During Shooting External Monitor AdjustmentSiemens Star Chart Object Back Focus Adjustment Power Zoom Lens To adjust, follow steps 3. ~10. above Setting procedures for Auto White AUTO1,AUTO2 Setting and Adjustment During ShootingWhite Balance Adjustment Menu SETErrorlow Light Insufficient Illumination Error DisplayNgobject Object Error Errorover Light Excessive IlluminationWhite Balance Screen White Shading AdjustmentMenu Screen Levelg and Levelb using the / buttons Set value starts blinking and adjustment is possibleRefer to the monitor to adjust values for Levelr Ance adjustment againButton Use Various Modes of ShootingShooting the Computer Monitor Tion to the screen If black bands are visible useSystem screen will be displayed Output of Negative ImageUse the / buttons to select SYSTEM.., then press White Spot Correction How To Use  Detection of White SpotsVarious Modes of Shooting PreparationDetecting Screen Detection Completed Screen Detection Error Screen White Spot Correction Messages Normal Screen Setting Via the Menu ScreenFlow of Menu Screens Main MenuNormal Setting Via the Menu Screen Setting ProceduresStep Exposure ScreenAuto EEI ShutterScan AdvancedNormal Advanced Exposure Screen200 White Balance Screen AutoLevelg PresetShading Process 1/2 Screen LOW108% Knee FunctionWhite Clip KneeStandard Process 2/2 ScreenOFF ManualFlare StretchCompress FlarerCyan Increase value Matrix Adjust ScreenRotation ColourCancel System Screen Save the set value File Manage Screen Display the File Manage screen Menu Screen Blinking Reset the set value  Retrieve fileConnection Connecting the Remote Control UnitOthers ENTER/SET FARNormal HI-RESO OFF ALC, ALC+EEI ALC/ALC+EEI Lolux ShutterSC Fine Zoom Focus HI-RESO White Shading MAX HI-RESO onOthers Connecting Optional Devices Installation of Option Card Compliance Range 2300 K 10000 K SpecificationsMANUAL, AUTO1, AUTO2, PRESET, FAW Dimensional Drawing Unit mm 166.8 12.4
Related manuals
Manual 49 pages 59.56 Kb

KY-F560 specifications

The JVC KY-F560 is a professional-grade camera that has carved a niche for itself in the broadcasting and production sectors. Designed with cutting-edge technology, the KY-F560 is tailored for high-definition video capture, making it a popular choice among video professionals.

One of the standout features of the JVC KY-F560 is its advanced 3CCD image sensor system. This system enables the camera to capture vivid colors and exceptional detail, producing images that are both vibrant and realistic. The 3CCD technology allows for improved light sensitivity, which is crucial when shooting in varying lighting conditions.

The camera supports a variety of video resolution formats, including 1080i, which is ideal for high-definition recordings. With its high-resolution capabilities, the KY-F560 ensures that even the smallest details are captured crisply and clearly. This performance is complemented by a range of lens options, allowing users to choose the most suitable lens for their specific shooting needs, from wide-angle to telephoto.

Another significant characteristic of the JVC KY-F560 is its user-friendly design. The camera features intuitive controls that make it accessible to both seasoned professionals and newcomers to the video production world. Its compact form factor allows for easy transportation and setup, which is particularly advantageous for on-location shoots.

The KY-F560 is also equipped with versatile connectivity options, including SDI and composite outputs, which facilitate seamless integration with other broadcasting equipment. This means that whether users are working in a studio or on a remote location, the camera can easily connect to switchers, recorders, and other essential gear.

The camera is designed for field use and is built to withstand the rigors of professional production environments. Its durable construction ensures reliability during demanding shooting sessions.

In summary, the JVC KY-F560 is a robust professional camera that combines advanced imaging technology, user-friendly features, and reliable performance. With its versatile functionalities and high-definition capabilities, it remains a solid choice for broadcasters, filmmakers, and content creators looking to achieve high-quality video production.