JVC 0597TOV*UN*VP, LYT0002-0Q4A Select White Balance, Adjust Focus, Adjust White Balance

Page 27

SELECT

27

Manual White Balance Adjustment (M.W.B.)

PROGRAM AE select dial

SET

White balance

M.W.B.

 

 

mode indicator

 

 

MWB

 

 

 

 

 

 

No indication (Auto) MWB

NOTES:

This camcorder’s Automatic Colour Temperature system senses the colour temperature of the ambient lighting for automatic white balance adjustment. However, precise colour adjust- ment is not possible under the following conditions:

When an object is in various shades of the same colour.

When a predominantly red or brown object is being shot outdoors.

In these cases, use the camcorder’s built-in preset filters for white balance adjustment.

SELECT MODE

1 Turn the PROGRAM AE select dial to any position except AUTO LOCK.

SELECT FUNCTION

2 Press SELECT reapeatedly until "M.W.B." appears.

SELECT WHITE BALANCE

3 Press SET (Manual White Balance) until the required indication appears in the viewfinder.

“MWB” ..... With a memorized personal White Balance

setting (see below)

” ......... Outdoors on sunny day

”......... Outdoors on cloudy day

” .......... Light source is halogen or tungsten lamp

MWB sets the colour temperature for the subject’s light source so you can shoot with natural colours that are unaffected by surroundings, even when there are multiple subjects with different colour temperatures.

MWB

SELECT MODE

1 Turn the PROGRAM AE select dial to any position except AUTO LOCK.

ADJUST FOCUS

2 Point the camcorder at a white, flat object such as a sheet of white paper, and adjust focus manually (pg. 21).

ADJUST WHITE BALANCE

3 Press SET until “MWB” appears, then press and hold SET for more than 3 seconds.

“MWB” blinks in the viewfinder during adjustment, then stops blinking but stays lit when adjustment is complete.

To switch to automatic white balance adjustment, press SET until the indication disappears, or turn the PROGRAM AE select dial to “AUTO LOCK”.

Re-adjust the White Balance when the lighting has changed, when the camcorder has been turned on and off again, or when the PROGRAM AE select dial’s position has been changed.

It is helpful to connect your camcorder to a colour monitor when adjusting the white balance (“Basic Connections” pg. 32).

When adjusted by putting coloured paper in front of the subject in step 2 (“ADJUST FOCUS”), this unit makes its colour temperature standard for automatic white balance. So you can enjoy shooting with different colours. For example, when adjusting with red, blue or yellow colours, the image becomes the colour which aproximates to green, orange or purple respectively.

Manual White Balance Adjustment is not possible when the PROGRAM AE select dial is set to SEPIA (pg. 19).

Image 27
Contents GR-SZ3000 Dear Customer It is recommended that youConnection to the mains supply in the United Kingdom Marked Some DO’S and DON’TS on the Safe USE of EquipmentZoom-out AC Power Adapter Cassette Adapter Battery PackCable Adapter Shoulder Strap Lithium Battery Editing cable Zoom-inBATT. Release EjectStop 2REW PLAY/PAUSE Detach Battery Pack PowerSupply Power Attach Battery PackCar Battery Charger/Adapter BH-V3E optional AA-V11EKDC cord Viewfinder Adjustment Near Start Clock OperationClose Menu MenuSET Recording Format Tape Length SettingRecording Format Setting SET Tape LengthClose Cassette Holder Loading/Unloading a CassetteOpen Cassette Holder INSERT/REMOVE CassetteInsert Hand Grip AdjustmentAdjust Strap Length Expand LoopAttach Strap Adjust LengthShoulder Strap Attachment Tripod MountingStop Recording Enter RECORD-STANDBY ModeLoad a Cassette Start ShootingRetake R/F Feature PurposeOperation RecordRecord-Standby Record-Standby Down Auto Pause Feature Purpose OperationRecord-Standby Up NormalQuick Rec Quick REC Feature Purpose OperationViewfinder After 1 secViewfinder Mode Dial Viewfinder ModeIndication Farnear FocusingLock Focus Release Focus LockFAR Near Exposure Control Picture StabilizerFade/Wipe Instant Titles Engage Wide ModeRestore Normal Screen Select Preset TitleNorm Press Select repeatedly until Disp. appears Choose Display ModeDate/Time Character Insert Select DisplayAdjust Focus Adjust White BalanceSelect White Balance Setting procedure depends on the function you select Using Menu For Detailed AdjustmentAccess Menu Screen Make SettingNorm OFFJlip ID no Menu FAR Near IndicatorTime-Lapse AnimationPlayback Basic Conn ections Turn on the camcorder, VCR and TV SET Y/C/CVBS SwitchScart connector on the VCR or TV Connect Camcorder to TV/VCRStop Playback PowerRewind or Fast-forward the tape PlaybackCounter R/M PLAY/PAUSE Stop REW FF Feature Remove Cassette from Adapter Cassette AdapterInsert Cassette in Adapter Play Back on Connected VCRVCR Recording deck Power switchTo Audio and Video connectors To Audio Video ConnectorsRM-V704U or RM-V700U provided Random Assemble Editing R.A. EditSET Remote to Operate VCR Operate the VCRConnect to Prepare CamcorderPrepare VCR Register Additional Scenes Access R.A. Edit Counter DisplayRegister Beginning of Scene Register END of SceneBegin Automatic Editing END Automatic EditingEdited Tape VCR Stop Buttons Functions Installing The BatteryPull OUT Battery Holder Replace Battery HolderSTART/STOP Viss INT. Time REC Time Interval Timer IndicatorRec Time Indicator Remote sensorInsert Editing Pause Play Audio dubbing indicatorTo MIC Capped Microphone DUBClean Viewfinder Cleaning The CamcorderClean Exterior Clean LensSymptom Blinks Lens Cover Warning indicatorWhen the camcorder is swung or Image is out of focusTape Time When no cassette is inserted the Cassette # Instant Titles Display $ Date/Time Character DisplayTape End Display Tape END ........... pg Recording Start/Stop Button ................ pg Retake F Button ................................ pgMicrophone Tally Lamp Power On IndicatorU I O Camera sensorDiopter Adjust Auto Mode Lock ModeRemote Control Unit Date/Time SettingDo not burn Do not modify or disassemble Use only specified chargersMake sure the cassette bears the S-VHS-C or VHS-C mark Special Notes on Video Heads Out connector Power source Power consumption Signal system PAL-typeDimensions 188 25 H 104 Weight Approx g Accessory Adjustment Auto/Manual adjustmentGR-SZ3000