Panasonic AK-HC930P manual Adjusting the lens flange back, Adjustment method, About 10 ft 3 m

Page 11

Adjusting the lens flange back

Adjust the flange back (distance from the surface where the lens is mounted to the surface where the images are formed) if the subject fails to be precisely focused at both the telephoto and wide-angle settings when zoom operations are to be performed.

Once adjusted, the flange back does not need to be adjusted again unless the lens is replaced.

Adjustment method

<Note>

For details on the adjustment method and positions of the lens parts, refer also to the instructions that accompany the lens.

About 10 ft (3 m)

1

Mount the lens on the camera. Do not forget to connect

5

 

the lens cable at this time.

 

2

Set the lens iris to manual, and open the iris.

6

3

Set the lighting in such a way that the appropriate video

7

 

output level is obtained at a distance of about 10 ft (3

 

meters) from the flange back adjustment chart.

 

 

If the video level is too high, use a filter or shutter.

 

4

Loosen the screw that secures the F.f (flange focus)

8

 

ring.

 

 

<Note>

 

 

Depending on the lens concerned, this ring may be

9

 

marked as the “F.b” (flange back) ring.

Set the zoom ring to the telephoto position either by manual or electrical means.

Shoot the flange back adjustment chart, and turn the distance ring to adjust the focus.

Set the zoom ring to the wide-angle position, and turn the F.f ring to adjust the focus. Take care not to move the distance ring.

Repeat steps 5 to 7 until the chart is focused properly at both the telephoto and wide-angle positions.

Tighten up the screw that secures the F.f ring.

11

Image 11
Contents Model AK-HC930P FCC Note For your safetyContents Overview FeaturesFDd Controls and their functionsUlti Format INCOM1 MIC ON/OFF switch MIC1 Talk Power LEDPower circuit breaker Breaker Incom connectors 1, 2 INCOM1, INCOM2Rear MIC1 connector MIC1 RCB connector RCBExternal power supply input connector DC MIC1 selector switch MIC1 F/RLens connector Lens Electronic shutter selector switch ShutterAWB/ABB start switch Auto W/B BAL VTR start/RET selector switch VTR/RETCenter mark Mounting the lensMount cap Lens clamp lever About 10 ft 3 m Adjusting the lens flange backAdjustment method Detaching the viewfinder Attaching the viewfinderStopper screw Lever Viewfinder Clamp screw Connecting a microphoneMicrophone Holder Audio in switch MIC in connectorTripod attachment Red lever Mounting the camera on a tripodDetaching the camera from the tripod attachment Tripod attachment Tripod platformSystem block diagram Component system configurationComponent connections in an SD system Outline of peripheral componentsROP cable Remote operation panel System connections 1 with Multi-Format Camera2z viewfinder Lens Multi-Format CameraLarge lens Build-up unit System connections 2 with build-up unitAK-HC930P System connections 3 with MSUStatus displays on viewfinder screen User menu Basic setting menu operationsMenu operations When the JOG dial is now pressed, the data is entered Operation Setting menu configurationHierarchical menus Linear Matrix PaintingDTL1 MaintenanceOPT Fiber EDW.3K.93C.TLC Hirakawa AK-HC930P Connector pin assignment11-1/16z280 mm 5z 126 mm External dimension drawings8 z 231.5 mm 14-3/8z365 mmBasic items SpecificationsInput/output signals Optional connectorsGovernment Marketing Department Executive OfficeSoutheast Region Central Region