Panasonic AW-RP50N Adjusting the minimum pan/tilt start speed, T MIN Speed Start

Page 26

Setting the functions

￿￿Adjusting the minimum pan/tilt start speed

The minimum speed at which the pan-tilt head is to start moving is automatically adjusted to ensure that the remote camera will start moving smoothly in line with the inclination of the PAN/TILT lever when manually operating the pan-tilt head using the joystick.

This adjustment enables the play in the PAN/TILT lever to be reduced.

From the [SETUP] menu, select [PTZ ADJ] and display [P/T MIN SPEED].Then press the F2 dial.

1.P/T MIN SPEED▼

START

When the automatic adjustment is completed, the indicators of both the PRESET MEMORY/MENU 9 button (SETUP) and the corresponding CAMERA STATUS/SELECTION button of the camera go off.

￿￿Adjusting the minimum lens zoom start speed

This adjustment ensures that the lens zoom will start moving smoothly in line with the inclination of the ZOOM button when operating the lens zoom using the ZOOM button.

From the [SETUP] menu, select [PTZ ADJ] and display [Z MIN SPEED]. Then turn the F2 dial to set the compensation amount.

2.Z MIN SPEED

0

The lowest compensation amount is “1”, and the highest is “8”.

No compensation is provided at the “0” setting.

While observing the images on a monitor, move the ZOOM button slowly, and check whether the lens zoom starts moving smoothly.

26

Image 26
Contents Operating Instructions Contents Before use How to turn the power of the remote cameras on and off How to turn the power of the remote cameras onHold down the Preset MEMORY/MENU button of the number on Setting and operating the preset memoriesRegistering data in the preset memories Preset numbers and registered pagesHold down the Preset MEMORY/MENU button for the number on Executing the preset dataDeleting the preset memory data Setting the pedestal Selecting the settings for a selected remote cameraSetting the gain Set the Preset MEMORY/MENU 2 button R/B Gain to on Setting the R and B gain valuesSetting the R and B pedestal Set the Preset MEMORY/MENU 3 button R/B PED to onTurn the F1 dial to select the white balance mode Setting the white balanceSet the Preset MEMORY/MENU 4 button AWB/ABB to on Selecting the white balance modeTurn the F2 dial to select AWB, and press the F2 dial Automatically adjusting the white balanceAWB Mode AWB a SET AWB Mode ATW SET Manually adjusting the white balanceAutomatic color temperature tracking ATW Turn the F1 dial to select ATWAWB Mode AWB B SET ABB Setting the black balanceAutomatically adjusting the black balance Manually adjusting the black balanceSet the Preset MEMORY/MENU 5 button Shutter to on Setting the shutter speedSetting the detail Turn the F1 dial to select the shutter modeTurn the F1 dial to select the shooting mode Setting the shooting modeSet the Preset MEMORY/MENU 7 button SCENE/MODE to on Specifying the color barsOperating the menu items of the selected remote camera Table of operationsRegistering functions User buttons Setting the User buttonsSet the Preset MEMORY/MENU 9 button Setup to on SwlinkSetting the functions Turn the F1 dial to select the target menu itemZoom DIR Normal Setting the remote camera operationsSetting the pan, tilt, zoom and focus operation directions Focus DIR NormalSpeed Target Selecting the control items pan, tilt, zoom and focusSpeed with Z Off Z/FFOCUS/IRIS Normal Switching from focus control to iris control or vice versaSetting the PAN/TILT lever inclination and speed T CurvScope Mode a Diag SpeedSetting the upper limit Setting the lower limitSetting the left limit Setting the right limitReturning the remote cameras to their home position Home Position SET6FUNCTION T MIN Speed Start Adjusting the minimum pan/tilt start speedAdjusting the minimum lens zoom start speed MIN SpeedMenu Control Enable 8GPI Setting the preset numbers10MENU CTL Setting button operation enable or disable Locking the button operationsSet Preset MEMORY/MENU 10 button System to on Linking the unit with the switcherSwitcher network settings Ipsw1CAMERA CTL Setting the image output and image inputTurn the F1 dial to select the input line of the switcher 3SW AssignTurn the F1 dial to select the menu item to be set Switcher settingsSet Preset MEMORY/MENU 9 button Setup to on 2SW LinkCamsel Off BUS AUXFasist Off Self Tallyip OffT Lever Turn the F1 dial to and select the menu item to be set Setting for the information to be displayed on the OSDSetting all the information displays together 3SW DispSetting each information item to be displayed Power No Alarm Checking the equipment alarm information8ALARM Turn the F2 dial to display the remote camera itemReturning the unit to its factory status Turn the F2 dial to select the initializing modePress the F2 dial to initialize the settings Example of GPIOut connections Control interface for external devicesSub 15-pin, female, inch thread Current Max mA AW-RP50IP settings RP setting toolInstalling the software Software provided on the CD-ROMChanging the camera numbers Auto IP settingChanging the IP addresses Click RenewInitializing the IP addresses Alarm displaysDisplaying the camera names Acquiring informationSystem section, click Save under From AW-RP50 Saving the setting filesSaving and loading data Input the filename, and click SaveLoading the setting files Saving the log filesTable of menu items Pedestal AW-HE50Video Setup Setup PTZ ADJ MIN Speed Start Limit UP AW-HE50 F0410Y0 Operating Instructions Basics Safety precautions FCC NoteImportant Safety Instructions Before use Overview Before use Characteristics Pan-tilt heads supported AccessoriesPan-tilt heads and cameras supported Required personal computer environment CPUChoosing the best installation location Installation precautionsConnecting the power supply Handle carefullyOperating precautions Parts and their functions Power indicator Power F1 dial, F2 dialAlarm indicator Alarm Control panelExit button Exit Preset MEMORY/MENU buttonsCamera OSD button Camera OSD User buttons USER1, USER2Iris dial Iris Auto focus button AutoFOCUS/PUSH OAF dial FOCUS/PUSH OAF Auto iris button AutoService switch SV/NM Power switch Power DC in socket DC 12Ground terminal Signal GND LAN connector LAN RJ-45 10BaseT/100BaseTXBasic operations of the unit Select the target menu Change the settings using the F1 dial and F2 dialBasic operations for the menus Network settings Setting the unit000 MAC AddressConnections with the AW-HE50 and AW-HS50 ConnectionsExample of IP connections Connection with the AW-HE100 Example of serial connectionsConnection with the AW-HE50 Connections with the AW-PH400 and camera Max m 3280 ftConnections with the AW-PH405 and camera Connection with the AW-PH650 IP connection Settings for connection with the remote camerasSerial connection Auto Setup Renew Setting the IP addresses automatically auto IP settingWhen setting the IP addresses for the first time YESTurn the F2 dial, select Yes, and then press the F2 dial Auto Setup Keep IP Duplicate ERR Selecting the camera group Setting the IP addressesChanging the IP addresses of the remote cameras Group SelectChanging the camera numbers Changing the IP address of the switcherAuto Setup ALL Clear Clearing the IP address control tablesSelecting the remote cameras to be operated Set the Preset MEMORY/MENU 8 Button Camera to onIndicator lighting statuses and remote camera statuses To cool down MaintenancePower plug from the power outlet, and allow the unit Appearance Unit mm inchAC adapter SpecificationsInput/Output connector F0410Y0
Related manuals
Manual 48 pages 18.08 Kb

AW-RP50N specifications

The Panasonic AW-RP50N is a sophisticated remote camera controller designed for professional video production environments. Renowned for its advanced features and versatility, the AW-RP50N serves as an essential tool for operators needing precise control over multiple cameras in real-time.

One of the standout characteristics of the AW-RP50N is its ability to control up to 200 Panasonic cameras simultaneously. This feature is particularly beneficial in large-scale productions, such as broadcasting events, live concerts, and sports. It not only enhances operational efficiency but also provides cinematographers with a centralized point for camera management.

The AW-RP50N boasts a user-friendly interface, equipped with a large LCD touch panel that allows easy navigation and adjustment of camera settings. The intuitive layout makes it simple for operators to switch between camera feeds, adjust PTZ (pan-tilt-zoom) settings, and monitor video feeds without interruption. Customizable settings enable users to tailor the interface to suit their workflow preferences.

In terms of technology, the AW-RP50N supports multiple communication protocols, including IP (Internet Protocol) and serial communication. This flexibility allows integration with various camera models and third-party systems, offering a cohesive control experience. The unit is designed with robustness in mind, ensuring reliability even in demanding environments.

The AW-RP50N features advanced zoom and focus controls, providing smooth and precise movements essential for capturing high-quality video content. With programmable presets, operators can save specific camera angles and settings, making it easy to quickly switch back to preferred positions during production.

Additionally, it supports HD/SD video formats, catering to diverse production needs. The unit's compact design also makes it an ideal choice for mobile setups and small production teams that require portability without sacrificing performance.

Overall, the Panasonic AW-RP50N remote camera controller is a remarkable piece of technology, combining scalability, ease of use, and high-performance capabilities. Its robust feature set makes it an indispensable asset for professionals in the broadcasting and production industry, ensuring dynamic and reliable control of remote cameras in any situation. Whether scaling a large production or managing a small shoot, the AW-RP50N enables creators to achieve their artistic vision with precision and ease.