Setting the functions

￿￿Setting the left limit

From the [SETUP] menu, select [PTZ ADJ] and display [LIMIT LEFT]. Then set the left limit.

The setting that is displayed differs between the AW-HE50 and other remote cameras.

Display that appears with the AW-HE50

￿￿Setting the right limit

From the [SETUP] menu, select [PTZ ADJ] and display [LIMIT RIGHT]. Then set the right limit.

The setting that is displayed differs between the AW-HE50 and other remote cameras.

Display that appears with the AW-HE50

The current setting status is displayed in the LIMIT LEFT item.

5.LIMIT LEFT Off

Turn the F2 dial, and then press it.

5.LIMIT LEFT On

Display that appears with other remote cameras

The setting status is displayed after the completion of the setting in the LIMIT LEFT item.

5.LIMIT LEFT EXEC

Press the F2 dial.

5.LIMIT LEFT LIMIT ON

The current setting status is displayed in the LIMIT RIGHT item.

6.LIMIT RIGHT ▲ Off

Turn the F2 dial, and then press it.

6.LIMIT RIGHT ▲ On

Display that appears with other remote cameras

The setting status is displayed after the completion of the setting in the LIMIT RIGHT item

6.LIMIT RIGHT ▲

EXEC

Press the F2 dial.

6.LIMIT RIGHT ▲

LIMIT ON

23

Image 23
Contents Operating Instructions Contents Before use How to turn the power of the remote cameras on How to turn the power of the remote cameras on and offPreset numbers and registered pages Setting and operating the preset memoriesRegistering data in the preset memories Hold down the Preset MEMORY/MENU button of the number onHold down the Preset MEMORY/MENU button for the number on Executing the preset dataDeleting the preset memory data Setting the pedestal Selecting the settings for a selected remote cameraSetting the gain Set the Preset MEMORY/MENU 3 button R/B PED to on Setting the R and B gain valuesSetting the R and B pedestal Set the Preset MEMORY/MENU 2 button R/B Gain to onSelecting the white balance mode Setting the white balanceSet the Preset MEMORY/MENU 4 button AWB/ABB to on Turn the F1 dial to select the white balance modeTurn the F2 dial to select AWB, and press the F2 dial Automatically adjusting the white balanceAWB Mode AWB a SET Turn the F1 dial to select ATW Manually adjusting the white balanceAutomatic color temperature tracking ATW AWB Mode ATW SETManually adjusting the black balance Setting the black balanceAutomatically adjusting the black balance AWB Mode AWB B SET ABBTurn the F1 dial to select the shutter mode Setting the shutter speedSetting the detail Set the Preset MEMORY/MENU 5 button Shutter to onSpecifying the color bars Setting the shooting modeSet the Preset MEMORY/MENU 7 button SCENE/MODE to on Turn the F1 dial to select the shooting modeTable of operations Operating the menu items of the selected remote cameraSwlink Setting the User buttonsSet the Preset MEMORY/MENU 9 button Setup to on Registering functions User buttonsTurn the F1 dial to select the target menu item Setting the functionsFocus DIR Normal Setting the remote camera operationsSetting the pan, tilt, zoom and focus operation directions Zoom DIR NormalZ/F Selecting the control items pan, tilt, zoom and focusSpeed with Z Off Speed TargetT Curv Switching from focus control to iris control or vice versaSetting the PAN/TILT lever inclination and speed FOCUS/IRIS NormalDiag Speed Scope Mode aSetting the lower limit Setting the upper limitSetting the right limit Setting the left limitHome Position SET Returning the remote cameras to their home position6FUNCTION MIN Speed Adjusting the minimum pan/tilt start speedAdjusting the minimum lens zoom start speed T MIN Speed StartLocking the button operations 8GPI Setting the preset numbers10MENU CTL Setting button operation enable or disable Menu Control EnableIpsw Linking the unit with the switcherSwitcher network settings Set Preset MEMORY/MENU 10 button System to on3SW Assign Setting the image output and image inputTurn the F1 dial to select the input line of the switcher 1CAMERA CTL2SW Link Switcher settingsSet Preset MEMORY/MENU 9 button Setup to on Turn the F1 dial to select the menu item to be setCamsel Off BUS AUXFasist Off Self Tallyip OffT Lever 3SW Disp Setting for the information to be displayed on the OSDSetting all the information displays together Turn the F1 dial to and select the menu item to be setSetting each information item to be displayed Turn the F2 dial to display the remote camera item Checking the equipment alarm information8ALARM Power No AlarmReturning the unit to its factory status Turn the F2 dial to select the initializing modePress the F2 dial to initialize the settings Current Max mA AW-RP50 Control interface for external devicesSub 15-pin, female, inch thread Example of GPIOut connectionsSoftware provided on the CD-ROM RP setting toolInstalling the software IP settingsClick Renew Auto IP settingChanging the IP addresses Changing the camera numbersAcquiring information Alarm displaysDisplaying the camera names Initializing the IP addressesInput the filename, and click Save Saving the setting filesSaving and loading data System section, click Save under From AW-RP50Saving the log files Loading the setting filesPedestal AW-HE50 Table of menu itemsVideo Setup Setup PTZ ADJ MIN Speed Start Limit UP AW-HE50 F0410Y0 Operating Instructions Basics FCC Note Safety precautionsImportant Safety Instructions Before use Overview Before use Characteristics Pan-tilt heads supported AccessoriesPan-tilt heads and cameras supported CPU Required personal computer environmentHandle carefully Installation precautionsConnecting the power supply Choosing the best installation locationOperating precautions Control panel Power indicator Power F1 dial, F2 dialAlarm indicator Alarm Parts and their functionsUser buttons USER1, USER2 Preset MEMORY/MENU buttonsCamera OSD button Camera OSD Exit button ExitAuto iris button Auto Auto focus button AutoFOCUS/PUSH OAF dial FOCUS/PUSH OAF Iris dial IrisLAN connector LAN RJ-45 10BaseT/100BaseTX Power switch Power DC in socket DC 12Ground terminal Signal GND Service switch SV/NMBasic operations of the unit Select the target menu Change the settings using the F1 dial and F2 dialBasic operations for the menus Setting the unit Network settingsMAC Address 000Connections with the AW-HE50 and AW-HS50 ConnectionsExample of IP connections Connection with the AW-HE100 Example of serial connectionsConnection with the AW-HE50 Max m 3280 ft Connections with the AW-PH400 and cameraConnections with the AW-PH405 and camera Connection with the AW-PH650 IP connection Settings for connection with the remote camerasSerial connection YES Setting the IP addresses automatically auto IP settingWhen setting the IP addresses for the first time Auto Setup RenewTurn the F2 dial, select Yes, and then press the F2 dial Auto Setup Keep IP Duplicate ERR Group Select Setting the IP addressesChanging the IP addresses of the remote cameras Selecting the camera groupClearing the IP address control tables Changing the IP address of the switcherAuto Setup ALL Clear Changing the camera numbersSelecting the remote cameras to be operated Set the Preset MEMORY/MENU 8 Button Camera to onIndicator lighting statuses and remote camera statuses To cool down MaintenancePower plug from the power outlet, and allow the unit Unit mm inch AppearanceAC adapter SpecificationsInput/Output connector F0410Y0
Related manuals
Manual 48 pages 18.08 Kb

AW-RP50N specifications

The Panasonic AW-RP50N is a sophisticated remote camera controller designed for professional video production environments. Renowned for its advanced features and versatility, the AW-RP50N serves as an essential tool for operators needing precise control over multiple cameras in real-time.

One of the standout characteristics of the AW-RP50N is its ability to control up to 200 Panasonic cameras simultaneously. This feature is particularly beneficial in large-scale productions, such as broadcasting events, live concerts, and sports. It not only enhances operational efficiency but also provides cinematographers with a centralized point for camera management.

The AW-RP50N boasts a user-friendly interface, equipped with a large LCD touch panel that allows easy navigation and adjustment of camera settings. The intuitive layout makes it simple for operators to switch between camera feeds, adjust PTZ (pan-tilt-zoom) settings, and monitor video feeds without interruption. Customizable settings enable users to tailor the interface to suit their workflow preferences.

In terms of technology, the AW-RP50N supports multiple communication protocols, including IP (Internet Protocol) and serial communication. This flexibility allows integration with various camera models and third-party systems, offering a cohesive control experience. The unit is designed with robustness in mind, ensuring reliability even in demanding environments.

The AW-RP50N features advanced zoom and focus controls, providing smooth and precise movements essential for capturing high-quality video content. With programmable presets, operators can save specific camera angles and settings, making it easy to quickly switch back to preferred positions during production.

Additionally, it supports HD/SD video formats, catering to diverse production needs. The unit's compact design also makes it an ideal choice for mobile setups and small production teams that require portability without sacrificing performance.

Overall, the Panasonic AW-RP50N remote camera controller is a remarkable piece of technology, combining scalability, ease of use, and high-performance capabilities. Its robust feature set makes it an indispensable asset for professionals in the broadcasting and production industry, ensuring dynamic and reliable control of remote cameras in any situation. Whether scaling a large production or managing a small shoot, the AW-RP50N enables creators to achieve their artistic vision with precision and ease.