Video and Audio

Audio Input

An external microphone or a line source can be connected to the Audio-in connector. Configure the audio input settings under Video & Audio > Audio Settings.

Note

A multi-connector cable (available from Axis) is required when connecting external audio equipment to the Axis product. See Multi-Connector Cable (sold separately).

Use the Input gain to control the volume (dB Full Scale) of the audio input. If the sound is too low, choose a higher dB, to amplify the sound. If the sound is too high, choose a lower dB. The Level bar gives a visual representation of the audio signal level in dB relative to the full-scale input level.

Green — the signal is at a good level.

Yellow — the signal is becoming distorted.

Red — the signal is distorted.

Use the Encoding option to select digital audio encoding format.

AAC requires a license for both encoding and decoding. AAC is the least complicated and most widely used codec. If achieving the best possible audio quality is a priority, AAC is the recommended codec to use. An AAC license is included in the Axis product.

G711 is an unlicensed standard codec that is useful when integrating audio into a VoIP system

G726 is an unlicensed speech codec that is most commonly used within the security industry.

Note

If recording audio to edge storage, such as an SD card or network share, use AAC encoding.

The Sample rate defines the number of times per second the sound is sampled. A higher sample rate will provide better audio quality, but also requires a greater bandwidth.

Set the required Bit rate depending on the selected encoding. A higher bit rate will give better audio quality. A lower bit rate may have latency or delay, but will require less bandwidth.

For more information about these settings, please see the online help .

Audio Output

An external speaker can be connected to the Audio-out connector (a built-in amplifier is required for this). The output can be connected to another amplifier with speakers. A stereo connector must be used for the audio out.

Configure the audio output settings under Video & Audio > Audio Settings.

Note

A multi-connector cable (available from Axis; Multi-Connector Cable (sold separately)) is required when connecting external audio equipment to the Axis product.

Output gain - Control the volume (dB Full Scale) of the line audio output. If the sound is too low, choose a higher dB. If the sound is too high, choose a lower dB.

Audio Clips

An audio clip is a sound file that can be played when events occur or directly from the Live View page. The audio clip must first be uploaded to the Axis product or recorded by a microphone connected to the product.

24

Image 24
Contents Axis Q6042 PTZ Dome Network Camera About this Document Legal ConsiderationsLiability Intellectual Property RightsSupport Learn MoreTable of Contents Axis Q6042 PTZ Dome Network CameraReset to Factory Default Settings Connectors Performance ConsiderationsConnectors and Buttons Network ConnectorFor technical specifications, see Hardware OverviewLED Indicators Multi-connectorPower Button SD Card SlotMidspan LED Indicators Green Steady when AC power input connectedAccess the Product Access from a BrowserAccess from the Internet Set the Root PasswordLive View Controls on the Live ViewClick Use Https Go to Setup Events Axis Media Control viewer toolbarManual Trigger To show the manual trigger buttons in the Live ViewPTZ Controls Speaker button Click to turn the speakers on or offAxis Q6042 PTZ Dome Network Camera How to Stream H.264 Media StreamsAxis Media Control AMC Alternative Methods of Accessing the Video Stream QuickTimeTM. The following paths can be usedAccess Audio Streams Java applet supports simplex audio with G.711 encodingSet Up the Product Basic SetupVideo and Audio Video StreamPixel Counter ImageStream Profiles 264Camera Settings Exposure SettingsImage Appearance White Balance Image Settings Overlay Overlay Image Go to Video & Audio Video Stream and select the Image tabUse Overlay Text in an Action Rule Go to Video & Audio Overlay ImageGo to Events Action Rules Audio Settings Privacy MaskAudio Modes Audio Clips Audio InputAudio Output Axis Q6042 PTZ Dome Network Camera Configure the Live View Default Viewer for BrowsersViewer Settings Browser Viewer DescriptionGo to Setup Live View Config User Defined LinksOutput Buttons Preset Positions Go to PTZ Preset PositionsPTZ Pan Tilt Zoom GatekeeperConfiguration AutotrackingExclude Areas Max LimitsGuard Tour Tour RecordingTo add a guard tour To add a recorded tourOsdi Zones AdvancedLimits ControlsOperator Same as administrator but with lower priority Control QueueSet Up Motion Detection Windows DetectorsShock Detection Motion DetectionAudio Detection Install Application Go to Setup ApplicationsApplications Application LicensesAxis Q6042 PTZ Dome Network Camera Set Up Action Rules EventsConvert Event Types to Action Rules Go to Events Action Rules and click AddTriggers Add Recipients ActionsRecipient Types Set Up Email Recipients Recipient Use with actionSet Up Recurrences Create SchedulesTo create a new schedule Go to Events Schedules and click AddRecordings Recording ListContinuous Recording Go to Recordings ListClick Save to save and start the recording Languages System Options SecurityUsers IP Address FilterIeee CertificatesGo to System Options Security Ieee To install a self-signed certificate Go to Setup System Options Security CertificatesClick Install certificate and upload the certificate Date & TimeBasic TCP/IP Settings NetworkAdvanced TCP/IP Settings Axis Internet Dynamic DNS ServiceAxis Internet Dynamic DNS Service requires IPv4 DNS ConfigurationNTP Configuration Host Name ConfigurationLink-Local IPv4 Address NAT traversal port mapping for IPv4QoS Quality of Service FTPUPnPTM can be disabled under System Options Network UPnPTM Smtp emailUPnPTM RTP/H.264Storage BonjourSD Card Mount and Unmount SD CardPorts & Devices Network SharePorts Port StatusMaintenance SupportSupport Overview System OverviewReset to Factory Default Settings Plain ConfigScripting File UploadAxis Q6042 PTZ Dome Network Camera Multi-Connector Cable sold separately Cable provides the following connectorsFunction Pin Specifications To max 40 V DC, open drain, 100 mAConnector Troubleshooting Upgrade the FirmwareEmergency Recovery Procedure Check the FirmwareSymptoms, Possible Causes and Remedial Actions Problems setting the IP addressProduct cannot be accessed from a browser Product is accessible locally but not externallyProblems with streaming H.264 Video and image problems, generalSetup Video & Audio Camera Settings Key framesSettings Storage and disk management problemsNo audio Poor audio qualityTechnical Specifications Function/group Specifications Network Security Installation aidMaintenance PowerConnectors Performance ConsiderationsAxis Q6042 PTZ Dome Network Camera M4.2