Axis Communications Q6042 PTZ Osdi Zones, Advanced, Limits, Controls, Formats in the online help

Page 31

AXIS Q6042 PTZ Dome Network Camera

PTZ (Pan Tilt Zoom)

1.Go to PTZ > Guard Tour and click Add.

2.Select Create a record tour and click OK.

3.Enter a descriptive name.

4.Specify the pause length between runs.

5.Click to start recording the Pan/Tilt/Zoom movements.

6.When satisfied, click.

7.Click OK.

Note

Only the name of the recorded tour and pause between runs can be modified. Starting a new recording will overwrite the existing guard tour.

The recorded tour can be activated from the Live View and Guard Tour pages or through events. For more information see the

online help .

OSDI Zones

On-Screen Direction Indicator (OSDI) zones can be included in the overlay text (see Overlay on page 21) to aid the user to navigate the Axis product. Each OSDI zone is set up with coordinates and a descriptive name.

OSDI zones are set up under PTZ > OSDI Zones. The Axis product uses the coordinates of the center of the view to set the lower left and upper right zone areas. First navigate to where you would like the lowermost left point of the OSDI zone to be located. Click Get to set the coordinates. Proceed to where the upper right point of zone should be located and click Get. Give the zone a descriptive name and click OK.

To include the name of the OSDI zone in the overlay text, go to Video & Audio < Video Stream < Overlay Settings. Check the Include text box and enter the modifier #L in the field. For more information about modifiers, see File Naming & Date/Time

Formats in the online help .

Advanced

Limits

Define the pan, tilt, zoom and focus limits for the Axis product. Movements to the left and right, up and down, can be restricted to narrow the area under surveillance.

Configure the near focus limit to avoid focusing on objects too close to the camera lens.

When Enable E-flipis selected, as it tilts down and continues to pan backwards, the Axis product will automatically correct the view and flip it 180 degrees. The left limit must be set to –180 degrees and the right limit to 180 degrees for e-flip to work.

Move speed sets the speed of the camera’s pan and tilt movements. The default setting is maximum speed.

When using a joystick (or emulating one with the mouse) the Enable proportional speed setting can be used to reduce the maximum pan/tilt movement speed, i.e. the speed the camera view moves at when the joystick is pushed all the way out in any direction. This is useful then the view is zoomed in on an object.

See the online help for more information.

Controls

Advanced PTZ settings can be configured under PTZ > Advanced > Controls.

31

Image 31
Contents Axis Q6042 PTZ Dome Network Camera Intellectual Property Rights About this DocumentLegal Considerations LiabilityLearn More SupportAxis Q6042 PTZ Dome Network Camera Table of ContentsConnectors Performance Considerations Reset to Factory Default SettingsHardware Overview Connectors and ButtonsNetwork Connector For technical specifications, seeSD Card Slot LED IndicatorsMulti-connector Power ButtonGreen Steady when AC power input connected Midspan LED IndicatorsSet the Root Password Access the ProductAccess from a Browser Access from the InternetControls on the Live View Live ViewClick Use Https To show the manual trigger buttons in the Live View Go to Setup EventsAxis Media Control viewer toolbar Manual TriggerSpeaker button Click to turn the speakers on or off PTZ ControlsAxis Q6042 PTZ Dome Network Camera Media Streams How to Stream H.264Axis Media Control AMC QuickTimeTM. The following paths can be used Alternative Methods of Accessing the Video StreamJava applet supports simplex audio with G.711 encoding Access Audio StreamsBasic Setup Set Up the ProductImage Video and AudioVideo Stream Pixel Counter264 Stream ProfilesWhite Balance Camera SettingsExposure Settings Image AppearanceGo to Video & Audio Video Stream and select the Image tab Image SettingsOverlay Overlay ImageGo to Video & Audio Overlay Image Use Overlay Text in an Action RuleGo to Events Action Rules Privacy Mask Audio SettingsAudio Modes Audio Input Audio ClipsAudio Output Axis Q6042 PTZ Dome Network Camera Browser Viewer Description Configure the Live ViewDefault Viewer for Browsers Viewer SettingsUser Defined Links Go to Setup Live View ConfigOutput Buttons Gatekeeper Preset Positions Go to PTZ Preset Positions PTZ Pan Tilt ZoomMax Limits ConfigurationAutotracking Exclude AreasTo add a recorded tour Guard TourTour Recording To add a guard tourControls Osdi ZonesAdvanced LimitsControl Queue Operator Same as administrator but with lower priorityMotion Detection Set Up Motion Detection WindowsDetectors Shock DetectionAudio Detection Application Licenses Install ApplicationGo to Setup Applications ApplicationsAxis Q6042 PTZ Dome Network Camera Go to Events Action Rules and click Add Set Up Action RulesEvents Convert Event Types to Action RulesTriggers Actions Add RecipientsRecipient Types Recipient Use with action Set Up Email RecipientsGo to Events Schedules and click Add Set Up RecurrencesCreate Schedules To create a new scheduleGo to Recordings List RecordingsRecording List Continuous RecordingClick Save to save and start the recording Languages IP Address Filter System OptionsSecurity UsersCertificates IeeeGo to System Options Security Ieee Date & Time To install a self-signed certificateGo to Setup System Options Security Certificates Click Install certificate and upload the certificateNetwork Basic TCP/IP SettingsDNS Configuration Advanced TCP/IP SettingsAxis Internet Dynamic DNS Service Axis Internet Dynamic DNS Service requires IPv4NAT traversal port mapping for IPv4 NTP ConfigurationHost Name Configuration Link-Local IPv4 AddressFTP QoS Quality of ServiceRTP/H.264 UPnPTM can be disabled under System Options Network UPnPTMSmtp email UPnPTMMount and Unmount SD Card StorageBonjour SD CardPort Status Ports & DevicesNetwork Share PortsSystem Overview MaintenanceSupport Support OverviewFile Upload Reset to Factory Default SettingsPlain Config ScriptingAxis Q6042 PTZ Dome Network Camera To max 40 V DC, open drain, 100 mA Multi-Connector Cable sold separatelyCable provides the following connectors Function Pin SpecificationsConnector Check the Firmware TroubleshootingUpgrade the Firmware Emergency Recovery ProcedureProduct is accessible locally but not externally Symptoms, Possible Causes and Remedial ActionsProblems setting the IP address Product cannot be accessed from a browserKey frames Problems with streaming H.264Video and image problems, general Setup Video & Audio Camera SettingsPoor audio quality SettingsStorage and disk management problems No audioTechnical Specifications Power Function/group Specifications Network SecurityInstallation aid MaintenancePerformance Considerations ConnectorsAxis Q6042 PTZ Dome Network Camera M4.2
Related manuals
Manual 68 pages 44.1 Kb