Axis Communications P3301 Audio Detection, Low level 0%, Recommended values, Default values

Page 28

AXIS P3301 Fixed Dome Network Camera

Detectors

Low level (0%)

Even very small objects trigger

An object that appears in

Only very bright objects on

 

motion detection.

the window triggers motion

a dark background trigger

 

 

detection only for a very short

motion detection.

 

 

time before it is considered as

 

 

 

non-moving.

 

 

 

 

 

Recommended values

5–15%

60–90%

75–95%

 

 

 

 

Default values

15%

90%

90%

 

 

 

 

Note

To trigger on small objects or movements, use several small motion detection windows rather than one large window and select a low object size.

To avoid triggering on small objects, select a high object size.

While monitoring an area where moving objects are not expected, select a high history level. This will cause motion detection to trigger as long as the object is present in the window.

To only detect flashing light, select a low sensitivity. In other cases high sensitivity is recommended.

Audio Detection

The Axis product can be configured to generate an alarm when audio rises above or falls below the threshold value. The threshold value can be set in the range 0–100 where 0 is the most sensitive and 100 the least sensitive.

1.Go to Detectors > Audio Detection.

2.Set the audio alarm level and click Save.

3.Go to Events > Action Rules and set up an action rule, see Set Up Action Rules on page 30.

Detected audio is indicated by colored peaks in the Activity indicator. An event is triggered when detected audio rises above or falls below the threshold value, which is represented by the bar.

28

Image 28
Contents Axis P3301 Fixed Dome Network Camera About this document Legal ConsiderationsLiability Intellectual Property RightsSupport Learn MoreTable of Contents Axis P3301 Fixed Dome Network CameraFor technical specifications, see Connectors and ButtonsHardware Overview LED Indicators Axis P3301 Fixed Dome Network Camera Access from a Browser Access the ProductStart a browser Internet Explorer, Firefox, Safari Set the Root Password Access from the InternetClick Create self-signed certificate Controls on the Live View Live ViewAxis Media Control viewer toolbar Half-duplex mode AMC Audio ControlsMedia Streams How to Stream H.264Axis Media Control AMC Alternative Methods of Accessing the Video Stream QuickTimeTM. The following paths can be usedAccess Audio Streams Java applet supports simplex audio with G.711 encodingBasic Setup Set Up the ProductFocus Adjustment Video Stream Video and AudioImage Click Save to apply the new settings 264Camera Settings Stream ProfilesIris adjustment OverlayOverlay Image Go to Video & Audio Video Stream and select the Image tabPrivacy Mask Audio SettingsAudio Modes Audio Input Audio Clips Audio OutputConfigure the Live View Default Viewer for BrowsersViewer Settings Go to Setup Live View ConfigUser Defined Links Output ButtonsFor more information about I/O ports, see I/O Ports on Detectors Camera TamperingMotion Detection Go to Detectors Camera TamperingSet Up Motion Detection Windows Motion Detection ParametersDefault values Audio DetectionLow level 0% Recommended valuesApplications Set Up Action Rules EventsConvert Event Types to Action Rules Go to Events Action Rules and click AddAdd Recipients Set Up RecurrencesCreate Schedules Recordings Recording ListContinuous Recording Go to Recordings ListClick Save to save and start the recording To log in again and be configured to use this functionality System OptionsSecurity UsersDate & Time IeeeAudio Support CertificatesBasic TCP/IP Settings IPv4 Address ConfigurationIPv6 Address Configuration NetworkAdvanced TCP/IP Settings Link-Local IPv4 Address Select Use the host name to set the host name manuallyNAT traversal port mapping for IPv4 QoS Quality of Service Smtp emailStorage UPnPTMRTP/H.264 BonjourMaintenance Ports & DevicesPorts Port StatusSupport AdvancedPlain Config Reset to Factory Default SettingsFile Upload Troubleshooting Upgrade the FirmwareFirmware To upgrade the product’s firmware Check the FirmwareEmergency Recovery Procedure Symptoms, Possible Causes and Remedial ActionsProblems setting the IP address Product cannot be accessed from a browserProblems with streaming H.264 Product is accessible locally but not externallyBasic Status and Network indicator LEDs are flashing red rapidly Video and image problems, generalSetup Video & Audio Camera Settings SettingsTechnical Specifications Function/group Specifications System Application Installation aidsMaintenance Memory PowerAccessories User license, smoked transparent cover Video Performance ConsiderationsM2.5