Axis Communications P1405-E user manual Reset to Factory Default Settings, Scripting, File Upload

Page 47

AXIS P1405–E Network Camera

System Options

Server Report - Provides information about the product status in a pop-up window. The Access Log is automatically included in the Server Report.

You can view or download the server report. Downloading the server report creates a .zip file that contains a complete server report text file in UTF–8 format. Select the Include snapshot with default image settings option to include a snapshot of the product’s Live View. The server report .zip file should always be included when contacting support.

Parameter List - Shows the product's parameters and their current settings. This may prove useful when troubleshooting or when contacting Axis Support.

Connection List - Lists all clients that are currently accessing media streams.

Crash Report - Generates an archive with debugging information. The report takes several minutes to generate.

The log levels for the System Log and the Access Log are set under System Options > Support > Logs & Reports > Configuration . The Access Log can be configured to list all connections to the product (select Critical, Warnings & Info).

Advanced

Scripting

Scripting allows experienced users to customize and use their own scripts.

NOTICE

Improper use may cause unexpected behavior and loss of contact with the Axis product.

Axis strongly recommends that you do not use this function unless you understand the consequences. Axis Support does not provide assistance for problems with customized scripts.

To open the Script Editor, go to System Options > Advanced > Scripting. If a script causes problems, reset the product to its factory default settings, see page 47.

For more information, see www.axis.com/developer

File Upload

Files, for example webpages and images, can be uploaded to the Axis product and used as custom settings. To upload a file, go to System Options > Advanced > File Upload.

Uploaded files are accessed through http://<ip address>/local/<user>/<file name> where <user> is the selected user group (viewer, operator or administrator) for the uploaded file.

Plain Config

Plain Config is for advanced users with experience of Axis product configuration. Most parameters can be set and modified from this page.

To open Plain Config, go to System Options > Advanced > Plain Config . Axis Support does not provide assistance.

Reset to Factory Default Settings

Important

Reset to factory default should be used with caution. A reset to factory default will reset all settings, including the IP address, to the factory default values.

47

Image 47
Contents Axis P1405-E Network Camera Intellectual Property Rights About this DocumentLegal Considerations LiabilityLearn More SupportAxis P1405-E Network Camera Table of ContentsSD Card Slot Connectors and ButtonsNetwork Connector Hardware OverviewStatus LED Indication LED IndicatorsControl Button Set the Root Password Access the ProductAccess from a Browser Access from the InternetClick Use Https Set Power Line FrequencyLive View Controls on the Live ViewManual Trigger Go to Setup EventsAxis Media Control viewer toolbar PTZ ControlsAxis P1405-E Network Camera Axis Media Control AMC How to Stream H.264Media Streams QuickTimeTM. The following paths can be used Alternative Methods of Accessing the Video StreamAxis P1405-E Network Camera Basic Setup Set Up the ProductImage Set Up Video StreamsVideo Pixel Counter264 Click Save to apply the new settingsStream Profiles White Balance Camera SettingsExposure Settings Image AppearanceDay/Night Iris adjustmentSet Shutter to Go to Video View Area Select an Aspect ratio and a Video stream resolutionView Area OverlayGo to Video Overlay Image Overlay ImageUse Overlay Text in an Action Rule Go to Video Focus & Zoom Privacy MaskFocus & Zoom Go to Events Action RulesWhen satisfied, click Enable iris to enable the iris Browser Viewer Description Configure the Live ViewDefault Viewer for Browsers Viewer SettingsUser Defined Links Guard Tour Preset PositionsPTZ Pan Tilt Zoom Controls AdvancedControl Queue Go to Detectors Camera Tampering DetectorsCamera Tampering Motion DetectionMotion Detection Parameters Set Up Motion Detection WindowsAxis P1405-E Network Camera Application Licenses Install ApplicationGo to Setup Applications ApplicationsAxis P1405-E Network Camera Go to Events Action Rules and click Add Set Up Action RulesEvents Fallback ActionGo to Events Recipients and click Add Set Up Email RecipientsAdd Recipients Create SchedulesGo to Events Recurrences and click Add Set Up RecurrencesGo to Recordings List RecordingsRecording List Continuous RecordingLanguages IP Address Filter System OptionsSecurity UsersGo to System Options Security Ieee IeeeCertificates Date & Time Basic TCP/IP SettingsGo to Setup System Options Security Certificates Click Install certificate and upload the certificateARP/Ping IPv4 Address ConfigurationIPv6 Address Configuration Assign IP Address Using ARP/PingDNS Configuration Advanced TCP/IP SettingsAxis Internet Dynamic DNS Service Axis Internet Dynamic DNS Service requires IPv4NAT traversal port mapping for IPv4 NTP ConfigurationHost Name Configuration Link-Local IPv4 AddressFTP QoS Quality of Service Bonjour UPnPTM can be disabled under System Options Network UPnPTM UPnPTM RTP/H.264To add a network share StorageSD Card Network ShareSystem Overview MaintenanceSupport Support OverviewFile Upload Reset to Factory Default SettingsPlain Config ScriptingAxis P1405-E Network Camera Check the Firmware TroubleshootingUpgrade the Firmware Emergency Recovery ProcedureProduct is accessible locally but not externally Symptoms, Possible Causes and Remedial ActionsProblems setting the IP address Product cannot be accessed from a browserKey frames Problems with streaming H.264Video and image problems, general Video Camera SettingsReformat the SD card and then click Mount Storage and disk management problemsStorage disruption Re-mount the storage deviceTechnical Specifications Dimensions Function/group Specifications System ApplicationPower ConnectorsPerformance Considerations ConnectorsM2.3