IPv4 Address Configuration

By default, the Axis product is set to use IPv4 (IP version 4) and to obtain the IP address automatically via DHCP. The IPv4 settings are configured under System Options > Network > TCP/IP > Basic.

DHCP (Dynamic Host Configuration Protocol) allows network administrators to centrally manage and automate the assignment of IP addresses. DHCP should only be enabled if using dynamic IP address notification, or if the DHCP can update a DNS server. It is then possible to access the Axis product by name (host name).

If DHCP is enabled and the product cannot be accessed, run AXIS IP Utility to search the network for connected Axis products, or reset the product to the factory default settings (see page 49) and then perform the installation again.

To use a static IP address, check Use the following IP address and specify the IP address, subnet mask and default router.

IPv6 Address Configuration

If IPv6 (IP version 6) is enabled, the Axis product will receive an IP address according to the configuration in the network router.

To enable IPv6, go to System Options > Network > TCP/IP > Basic. Other settings for IPv6 should be configured in the network router.

ARP/Ping

The product’s IP address can be assigned using ARP and Ping. For instructions, see Assign IP Address Using ARP/Ping on page 42.

The ARP/Ping service is enabled by default but is automatically disabled two minutes after the product is started, or as soon as an IP address is assigned. To re-assign IP address using ARP/Ping, the product must be restarted to enable ARP/Ping for an additional two minutes.

To disable the service, go to System Options > Network > TCP/IP > Basic and clear the option Enable ARP/Ping setting of IP address.

Pinging the product is still possible when the service is disabled.

Assign IP Address Using ARP/Ping

The product's IP address can be assigned using ARP/Ping. The command must be issued within 2 minutes of connecting power.

1.Acquire a free static IP address on the same network segment as the computer.

2.Locate the serial number (S/N) on the product label.

3.Open a command prompt and enter the following commands:

Linux/Unix syntax

arp -s <IP address> <serial number> temp ping -s 408 <IP address>

Linux/Unix example

arp -s 192.168.0.125 00:40:8c:18:10:00 temp ping -s 408 192.168.0.125

Windows syntax (this may require that you run the command prompt as an administrator)

arp -s <IP address> <serial number> ping -l 408 -t <IP address>

Windows example (this may require that you run the command prompt as an administrator)

arp -s 192.168.0.125 00-40-8c-18-10-00 ping -l 408 -t 192.168.0.125

4.Check that the network cable is connected and then restart the product by disconnecting and reconnecting power.

42

Image 42
Contents Axis P1405-LE Network Camera Liability About this DocumentLegal Considerations Intellectual Property RightsSupport Learn MoreTable of Contents Axis P1405-LE Network CameraHardware Overview Connectors and ButtonsNetwork Connector SD Card SlotLED Indicators Color IndicationAccess from the Internet Accessing the ProductAccess from a Browser Set the Root PasswordControls on the Live View Set Power Line FrequencyLive View Click Use HttpsPTZ Controls Go to Setup EventsAxis Media Control viewer toolbar Manual TriggerAxis P1405-LE Network Camera How to Stream H.264 Media StreamsAxis Media Control AMC Alternative Methods of Accessing the Video Stream Axis P1405-LE Network Camera Setting Up the Product Basic SetupPixel Counter VideoVideo Stream ImageStream Profiles 264Image Appearance Camera SettingsExposure Settings White BalanceIris adjustment Built-in IR Illuminations LEDsDay/Night Overlay Select an Aspect ratio and a Video stream resolutionView Area Go to Video View AreaUsing Overlay Text in an Action Rule Overlay ImageGo to Video Overlay Image Go to Events Action Rules Privacy MaskFocus & Zoom Go to Video Focus & ZoomAxis P1405-LE Network Camera Viewer Settings Live View ConfigDefault Viewer for Browsers Browser Viewer DescriptionUser Defined Links Light ButtonsPTZ Pan Tilt Zoom Preset PositionsGo to PTZ Preset Positions Guard TourAdvanced Control QueueControls Motion Detection DetectorsCamera Tampering Go to Detectors Camera TamperingSet Up Motion Detection Windows Motion Detection ParametersAxis P1405-LE Network Camera Applications Install ApplicationGo to Setup Applications Application LicensesAxis P1405-LE Network Camera Events PTZ Control Setting Up an Action RuleTime Go to Events Action Rules and click AddRecipient Use with action RecipientsFallback Action Go to Events Recipients and click AddRecurrences Setting Up an Email RecipientSchedules Go to Events Schedules and click AddAxis P1405-LE Network Camera Continuous Recording RecordingsRecording List Go to Recordings ListLanguages Users System OptionsSecurity IP Address FilterIeee CertificatesGo to System Options Security Ieee Date & Time Basic TCP/IP SettingsGo to Setup System Options Security Certificates NetworkAssign IP Address Using ARP/Ping IPv4 Address ConfigurationIPv6 Address Configuration ARP/PingDNS Configuration Advanced TCP/IP SettingsAxis Internet Dynamic DNS Service Axis Video Hosting System AvhsLink-Local IPv4 Address NTP ConfigurationHost Name Configuration NAT traversal port mapping for IPv4QoS Quality of Service FTPRTP/H.264 StorageUPnPTM BonjourNetwork Share Go to System Options Storage and click SD CardGo to System Options Storage Click Network Share Support Overview MaintenanceSupport System OverviewScripting Reset to Factory Default SettingsPlain Config File UploadAxis P1405-LE Network Camera Checking the Firmware TroubleshootingEmergency Recovery Procedure Upgrading the FirmwareProduct cannot be accessed from a browser Symptoms, Possible Causes and Remedial ActionsProblems setting the IP address Product is accessible locally but not externallyVideo Camera Settings Problems with streaming H.264Video and image problems, general Key framesStorage and disk management problems Storage disruptionTechnical Specifications Connectors Function/group Specifications System ApplicationPower DimensionsConnectors Performance ConsiderationsM1.3