Axis Communications P1224-E user manual Set Power Line Frequency, Controls on the Live View

Page 9

AXIS P1224–E Network Camera

Accessing the Product

The default administrator user name root is permanent and cannot be deleted. If the password for root is lost, the product must be reset to the factory default settings. See Reset to Factory Default Settings on page 43.

To set the password via a standard HTTP connection, enter it directly in the dialog.

To set the password via an encrypted HTTPS connection, follow these steps:

1.Click Use HTTPS.

A temporary certificate (valid for one year) is created, enabling encryption of all traffic to and from the product, and the password can now be set securely.

2.Enter a password and then re-enter it to confirm the spelling.

3.Click OK. The password has now been configured.

Set Power Line Frequency

Power line frequency is set the first time the Axis product is accessed and can only be changed from Plain Config (see page 43) or by resetting the product to factory default.

Select the power line frequency (50 Hz or 60 Hz) used at the location of the Axis product. Selecting the wrong frequency may cause image flicker if the product is used in fluorescent light environments.

When using 50 Hz, the maximum frame rate is limited to 25 fps.

Note

Power line frequency varies depending on geographic region. The Americas usually use 60 Hz, whereas most other parts of the world use 50 Hz. Local variations could apply. Always check with the local authorities.

The Live View Page

The controls and layout of the Live View page may have been customized to meet specific installation requirements and user preferences. Consequently, some of the examples and functions featured here may differ from those displayed in your own Live View page. The following provides an overview of each available control.

Controls on the Live View Page

Click View size to scale the image down to 800 pixels wide or to full scale. Only available in MJPEG.

Select a stream profile for the Live View page from the Stream Profile drop-down list. For information about how to configure stream profiles, see page 16.

Click Pulse to activate the product’s output port for a defined period of time. For information about how to enable and configure output buttons, see page 21.

Click the Active/Inactive buttons to manually activate and inactive the product’s output port. For information about how to enable and configure output buttons, see page 21.

9

Image 9
Contents Axis P1224-E Network Camera Legal Considerations About this DocumentLiability Intellectual Property RightsLearn More SupportAxis P1224-E Network Camera Table of ContentsShorten Sensor Unit Cable Hardware OverviewNetwork Connector Connectors and ButtonsRJ12 Connector ConnectorSD Card Slot LED IndicatorsControl Button Color IndicationAccess from a Browser Accessing the ProductAccess from the Internet Set the Root PasswordLive View Set Power Line FrequencyControls on the Live View Click Use HttpsAxis Media Control viewer toolbar Go to Setup EventsManual Trigger AMC Audio ControlsHow to Stream H.264 Media StreamsAxis Media Control AMC Alternative Methods of Accessing the Video Stream Axis P1224-E Network Camera Basic Setup Setting Up the ProductVideo Stream VideoPixel Counter ImageCamera Settings Stream Profiles264 Overlay Exposure SettingsImage Appearance White BalancePrivacy Mask Overlay ImageGo to Video Overlay Image Axis P1224-E Network Camera Default Viewer for Browsers Live View ConfigViewer Settings Browser Viewer DescriptionGo to Setup Live View Config User Defined LinksOutput Buttons Camera Tampering DetectorsMotion Detection Go to Detectors Camera TamperingMotion Detection Parameters Set Up Motion Detection WindowsAxis P1224-E Network Camera Go to Setup Applications Install ApplicationApplications Application LicensesAxis P1224-E Network Camera Events Recipients Setting Up an Action RuleGo to Events Action Rules and click Add Recipient Use with actionSchedules Setting Up an Email RecipientRecurrences Go to Events Recipients and click AddGo to Events Recurrences and click Add Recording List RecordingsContinuous Recording Go to Recordings ListSecurity System OptionsUsers IP Address FilterIeee CertificatesGo to System Options Security Ieee Go to Setup System Options Security Certificates Basic TCP/IP SettingsDate & Time NetworkIPv6 Address Configuration IPv4 Address ConfigurationAssign IP Address Using ARP/Ping ARP/PingAxis Internet Dynamic DNS Service Advanced TCP/IP SettingsDNS Configuration Axis Video Hosting System AvhsHost Name Configuration NTP ConfigurationLink-Local IPv4 Address NAT traversal port mapping for IPv4FTP QoS Quality of ServiceUPnPTM StorageRTP/H.264 BonjourNetwork Share Go to System Options Storage and click SD CardGo to System Options Storage Click Network Share Maintenance Ports & DevicesSupport System Overview AdvancedLogs & Reports ScriptingPlain Config Reset to Factory Default SettingsEmergency Recovery Procedure TroubleshootingChecking the Firmware Upgrading the FirmwareProblems setting the IP address Symptoms, Possible Causes and Remedial ActionsProduct cannot be accessed from a browser Product is accessible locally but not externallyStatus and Network indicator LEDs are flashing red rapidly Problems with streaming H.264Video and image problems, general Video Camera SettingsStorage disruption Storage and disk management problemsTechnical Specifications Installation Function/group SpecificationsMaintenance Built-in Installation aids General CasingConnectors Function/group Specifications WarrantyFunction Pin Specifications Performance Considerations M3.2