WindChaser Products PACRWC Operating Instructions And Functions, Control Panel, Main Led Display

Models: PACRWC

1 8
Download 8 pages 11.69 Kb
Page 8
Image 8
OPERATING INSTRUCTIONS

6)The air conditioner can now be plugged into a 110- 120V/60Hz dedicated 15amp or greater circuit. You are advised not to use an extension cord, however, if this is unavoidable, the extension cord must be 14 gauge, grounded at both ends and not more than 30 feet long.

If you need to extend your exhaust hose, it may be extended 5 feet only. Using a 5 foot, 4 inch diameter PVC pipe (available at your local hardware store), you must cut the exhaust hose in half and duct tape the PVC pipe in between the two cut pieces of the exhaust hose for a maximum exhaust length of 10.9 feet. Flex ducting is also recommended for extending the exhaust hose. DO NOT USE ALUMINUM TYPE EXHAUST HOSE TO LENGTHEN THE EXHAUST.

The compressor is an essential component of the appliance for producing cold air. This appliance is fitted with a thermal protection device which allows the compressor to be started only after a time delay of up to three minutes.

BEFORE OPERATING THE UNIT, BE SURE THE DRAIN PIPE IS CAPPED WITH THE DRAIN PLUG.

OPERATING INSTRUCTIONS

AND FUNCTIONS

SOFT TOUCH CONTROLS AND FUNCTIONS

Control Panel

1)Power On/Off SOFT TOUCH CONTROLS AND FUNCTIONS Starts or Stops the Unit

2)Time On Button Control PanelOperating FunctionsMAIN LED DISPLAY

To program the timer, press Timer On button until the Main LED display shows a flashing ‘ LED DISPLAYADJUSTABLE DIAL:Manual background ’. Turn the adjustable dial switch to change the timer to the desired time for the unit being turned on. Turn clockwise for increase in time and counter cloclwise for decrease in time.

3)Time Off Button Manual backgroundManual backgroundManual background

Press Timer Off button and the Main LED display will show a flashing ‘ Manual backgroundManual backgroundManual background ’. Turn the adjustable dial switch to change the clock to the desired time for the unit being turned off. Turn clockwise for increase in time

and counter cloclwise for decrease in time.

The light will flash for 3 seconds to activate the timer you have just programmed.

4)Ion Button

Press the Ion Button until ‘ ’ appears on Main LED display, press again to stop.

5)Temperature/ Humidity Button

To display temperature or humidity on both the Main LED and LED Display. Hold the button more than 3 seconds, to convert the temperature display from Fahrenheit (oF) to Celsius (oC) and vice versa. To adjust the desired

temperature setting turn the Adjustable Dial clockwise for increase of temperature or counter clockwise for decrease of temperature.

NOTE: This function can only be used while in cooling and heating mode.

Press the button less than 3 seconds, to convert the display from humidity to room temperature and vice versa.

Operating Functions

1)Cooling Operation

a)Install the exhaust ducts properly.

b)Plug the Power Cord to the power outlet.

c)Turn on the unit by pressing the ' Manual background 'Button on the control panel.

d) Press Mode Button until ‘ ‘ appears on the Main LED display

e)Turn the adjustable dial switch until the desired room temperature appears on the LED. The desired

temperature range is from 61oF-88 oF (16oC-31oC).

f)Select the fan speed by pressing the Fan Button. NOTE: During hot days, the unit will cool off the room most efficiently by setting the temperature at the lowest and the fan speed at the highest. Reducing the length of the exhaust duct and insulating the exhaust duct and keeping direct sunlight to a minimum will also improve the cooling efficiency.

*WE RECOMMEND SETTING THE DESIRED ROOM

TEMPERATURE AT 70oF (21oC) OR ABOVE WHEN FIRST ATTEMPTING TO COOL THE ROOM (ROOM

TEMPERATURE IN EXCESS OF 85oF (29oC) ). ONCE

THE ROOM HAS COOLED BELOW 80oF (26oC), YOU MAY ADJUST THE DESIRED ROOM TEMPERATURE

BELOW THE INITIAL 70oF (21oC) SETTING.

2) Dehumidifying Operation

 

a) Install the exhaust ducts properly

 

b) Plug the Power Cord into the power outlet.

c) Turn on the unit by pressing the '

' Button on the

control panel.

 

d) Press the Mode Button until the ‘

‘ appears on the

e)Select the fan speed by pressing the Fan button. It is recommended to use the low fan speed.

NOTE: When the unit is running on heating mode, the exhaust duct is inoperative and is not required.

5)Auto Operation

a)Install the exhaust ducts properly

b)Plug the Power Cord into the power outlet.

c)Turn on the unit by pressing the ' Manual background ' Button on the control panel.

d)Press the Mode Button until the ‘ Manual background ‘ appears on the Main LED display.

e)Select the fan speed by using FAN button.

During AUTO mode, the unit operates in heating mode

when the room temperature is below 68oF (20oC). It operates in dehumidifying mode when the room

temperature is between 68oF (20oC) to 80oF(26.6oC). It operates in cooling mode when the room temperature is

above 80oF(26.6oC). You may use the timer with the AUTO mode.

6)Sleep Mode

a)The air conditioner is in operation

b)Press SLEEP Button, the symbol ‘ Manual background ‘ appears on the Main LED display.

c)The fan motor will run on low speed

d)When in cooling mode, within the first two hours, the temperature will be increased by one degree per hour.

Then the temperature will be kept at 2 oF higher

than the originally set temperature for 6 hours. 6 hours

1)

10)

11)

The room temperature display range is from 32oF- 99oF (0oC- 37oC) .

NOTE: The display temperature may differ from actual temperature by ±4 oF ( ±2 oC )

6) Fan Speed Button

Select the fan speed desired: High, Medium or Low

Main LED display.NOTE: The unit operates at low fan

speed during dehumidifying. The unit cools room slightly

during the dehumidification. Keep the windows and the

doors closed to aid in the effectiveness of the unit in

removing the moisture from the room. The unit will not

perform dehumidification function when the room

temperature is lower than 61oF(16oC).

later, the temperature will return to the original setting.

e) When in heating mode, within the first 2 hours, the

temperature will decrease by one degree per hour.

Then the temperature will be kept at 2 degrees lower

than the original temperature for 6 hours. 6 hours later,

the temperature will return to its original setting.

g) When in dehumidifying mode, the temperature will not

be changed.

2)

 

 

 

 

 

9)

3)

4)

5)

6)

7)

8)

 

 

 

 

MAIN LED DISPLAY

LED DISPLAY

ADJUSTABLE DIAL:

THERMOSTAT & TIMER

 

 

Decrease

Increase

The fan speed can be visually distinguished by the speed

of the digital air segments progressing out from the

windmill fan image on the Main LED display.

 

7) Mode Button

 

Select the functions of the unit for: Fan Mode

,

Cooling Mode , Heating Mode Manual backgroundManual backgroundManual background, Dehumidifying Mode and Auto Mode Manual background .

8)Sleep Button Manual background

Press to select the function of the unit for Sleep Mode.

9)Swing Button Manual background

To start swinging air louvers horizontally by press SWING Button once. The symbol, ' Manual background' will appear on the Main LED display. To stop, press SWING again. Vertical air flow direction can be adjusted manually.

10)Power Indicator Light Indicates the unit is on.

11)Run Indicator Light

Indicates the unit is in working mode

3)Fan Operation

a) Plug the Power Cord into the power outlet.

b) Turn the unit on by pressing the '

 

' Button on the

 

control panel.

 

 

c)Press the Mode Button until ‘ Manual background ‘ appears on the Main LED display.

d)Select the fan speed by pressing the Fan Button. NOTE: When the unit is running on fan mode, the exhaust duct is inoperative and is not required.

4)Heating Operation

a)Plug the Power Cord into the power outlet.

b) Turn on the unit by pressing the '

 

' Button on the

 

control panel.

 

 

c)Press the Mode Button until ‘ Manual backgroundManual backgroundManual background‘ appears on the Main LED display.

d)Turn the adjustable dial switch until the desired room temperature appears on the LED. The desired temperature range is from 61oF-88oF (16oC-31oC).

NOTE: When the room temperature is low and the indoor humidity is high, the condensation formed by the air conditioner in use may not be discharged quickly. The symbol ‘ Manual background ‘ appears on the Main LED display. In order for your unit to continue to run, you can pull out the "Drain Port" which is located in the lower left bottom of the back of the unit. The condensation will be discharged several minutes after the water has been drained. Please use at least a 3.17 pint pan to catch the dripping water. It is not advisable to use the continuous drain method when the

room temperature is higher than 88o (31oC).

6

7

Page 8
Image 8
WindChaser Products PACRWC Operating Instructions And Functions, Soft Touch Controls And Functions, Control Panel