AutoDome 7000 Series (IP and HD) | Configuration via IP, Advanced Mode en 127 |
|
|
14.37Alarm Task Editor
Caution!
Editing scripts on this page overwrites all settings and entries on the other alarm pages. This
!procedure cannot be reversed.
In order to edit this page, you must have programming knowledge and be familiar with the information in the Alarm Task Script Language document.
As an alternative to the alarm settings on the various alarm pages, you can enter your desired alarm functions in script form here. This will overwrite all settings and entries on the other alarm pages.
1.Click the Examples link under the Alarm Task Editor field to see some script examples. A new window will open.
2.Enter new scripts in the Alarm Task Editor field or change existing scripts in line with your requirements.
3.When you are finished, click the Set button to transmit the scripts to the unit. If the transfer was successful, the message Script successfully parsed is displayed over the text field. If it was not successful, an error message will be displayed with further information.
14.38Alarm Rules
The camera features an alarm rule engine. In its simplest form, an alarm rule can define which input(s) activate which output(s). Basically, an alarm rule allows you to customize the camera to respond automatically to different alarm inputs.
To configure an alarm rule specify one input from a physical connection, a motion detection trigger, or from a connection to the camera’s LIVEPAGE. The physical input connection can be activated by dry contact devices such as pressure pads, door contacts, and similar devices. Next, specify up to two (2) rule outputs, or the camera’s response to the input. Outputs include a physical alarm relay, an AUX command, or a preposition scene.
1.Click the Enabled check box to activate the alarm.
2.Choose one of the following alarm Inputs: Local Input 1: a physical alarm connection. Local Input 2: a physical alarm connection.
IVA/MOTION+: an alarm when IVA or motion detection is activated.
Connection: an alarm when an attempt is made to access the camera’s IP address.
3.Choose one of the following output commands for both Output 1 and Output 2 settings: None: no defined command.
Alarm Relay: defines a physical connection from the open collector alarm output.
Aux On: defines a standard or custom keyboard ON command. Refer to User Command Table, page 158 for a list of valid commands.
Note: Only commands 1, 8, 18, 20, 43, 60, 80, 86 are supported. Support for the remaining commands is scheduled for a future release.
Aux Off: defines a standard or custom keyboard OFF command. Refer to to User Command Table, page 158 for a list of valid commands.
Note: Only commands 1, 8, 18, 20, 43, 60, 80, 86 are supported. Support for the remaining commands is scheduled for a future release.
Shot: defines a preset scene from shot
4.Click Set to save and to activate the alarm rules.
Bosch Security Systems | Operation Manual | 2013.07 1.2.2 F.01U.283.679 |