SETTING PROCEDURES
2-2. ALC Mode with SUPER-D2 OFF and ELC Mode
Note: If ELC is selected, set MASK SET according to this procedure.
1.Move the cursor to
2.Move the cursor to MASK SET and press I. The 48 mask areas appear on the monitor screen. The cursor is blinking in the upper left corner of the screen.
** ALC CONT **
BACK LIGHT COMP
OFF |
| ||
MASK SET | ↵ |
| |
LEVEL |
| ...I | |
|
| - | + |
RET | END |
|
|
| Blinking |
|
3.Move the cursor to the area where backlight is bright and press I to mask that area. The mask turns to white. (When the cursor is moved on an area that has already been masked, the mask and cursor start blinking.)
4.Repeat step 3 to mask the desired
area. To cancel masking, move the cursor to that area and press I.
5.After masking is completed, press I for 2 seconds or more. The ALC CONT menu appears.
6.If you want to change the video output level (picture contrast), move the “I” cursor for LEVEL and adjust the level.
Blinking
Turns to white
Blinking
Note: If ON is selected for
3. Shutter Speed Setting (SHUTTER)
Note: When ELC is selected for ALC/ELC on the CAM SET UP menu or ON is selected for
To select electronic shutter speed, select OFF for
Move the cursor to SHUTTER and select the electronic shutter speed.
The preset values for SHUTTER (electronic shutter speed) change by pressing L or M | ||||
as follows: |
|
|
|
|
The factory default setting is | OFF (1/60) | 1/100 | 1/250 | 1/500 |
| ||||
| 1/10000 | 1/4000 | 1/2000 | 1/1000 |
4. Gain Control Setting (AGC ON (DNR-H, DNR-L)/OFF)
AGC (Automatic Gain Control) automatically controls the gain (an image brightness level). Move the cursor to AGC and select automatic level adjustment ON
ON
ON
OFF: This setting does not control the gain.
Notes:
•When ON
•
5.Electronic Sensitivity Enhancement (SENS UP)
There are two modes for SENS UP.
AUTO: If you select X10 AUTO, for example, the sensitivity is automatically raised to X10 max. When AUTO is selected, AGC is automatically set to ON.
FIX: If you select X32 FIX, for example, the sensitivity is raised to just X32. The factory default setting is OFF.
Move the cursor to SENS UP and select the parameter for electronic sensitivity enhance- ment.
The preset values for SENS UP (electronic sensitivity enhancement) change by pressing L or M as shown right:
OFF X2 AUTO X4 AUTO X6 AUTO X10 AUTO OFF
X32 FIX X16 FIX X10 FIX X6 FIX X4 FIX X2 FIX
Notes:
•When ON is selected for
•When you select AUTO for SENS UP and ON for
•While the SENS UP function is selected, noise, spots or a whitish phenomenon may appear in the picture when the sensitivity of the camera is increased. This is a normal phenomenon.