C. WV-BP334 (24V AC 60Hz)
Connect the power cable to the AC24V IN terminal on the rear panel of the
1 2
24 V AC, 60 Hz
(19.5 V - 28 V)
Recommended wire gauge sizes for 24V AC line
Copper wire |
| #24 | #22 | #20 | #18 | |
size (AWG) |
| (0.22mm2) | (0.33mm2) | (0.52mm2) | (0.83mm2) | |
|
|
|
|
|
|
|
Length |
| (m) | 95 | 150 | 255 | 425 |
of Cable |
|
|
|
|
|
|
|
|
|
|
|
| |
(Approx.) |
| (ft) | 314 | 495 | 842 | 1 403 |
|
|
|
|
|
|
|
Caution:
To prevent fire or electric shock hazard, a UL listed wire
Video Cable
1.It is recommended to use a monitor whose resolu- tion is at least equal to that of the camera.
2.Set the termination switch to the 75Ω position on the last monitor.
A.Use a 75Ω coaxial cable.
B.Set the termination switch to the 75Ω posi- tion on the last monitor and to the
MonitorMonitor
| VIDEO |
|
| VIDEO |
|
IN | OUT | 75 ¶ | IN | OUT | 75 ¶ |
|
|
|
|
C. The maximum extensible coaxial cable length between the camera and the monitor is shown below.