Panasonic WV-BP334, WV-BP332 manual Focus or FLANGE-BACK Adjustment

Page 15

FOCUS OR FLANGE-BACK ADJUSTMENT

The following adjustment should be made by qualified service personnel or system installers.

1.Loosen the screws on the flange-back adjusting ring.

Focus adjustment for

CS-mount lens Focus adjustment for

C-mount lens

Flange-back

Adjusting Ring

Screws

3.Tighten the screws on the flange-back adjusting ring.

Note: If the camera is connected to the Quad System, glare may appear at the edge of the camera picture on the monitor.

If this bothers you, adjust the lens focus to reduce the glare.

2.Turn the flange-back adjusting ring to the desired position.

Caution: When the C-mount lens is mounted, do not rotate the ring counterclockwise by force after it stops. If the ring is rotated by force, the inner lens or CCD image sensor may be dam- aged.

-13-

Image 15
Contents English WV-BP330/WV-BP332/WV-BP334For U.S.A Contents Preface FeaturesHandle the camera with care PrecautionsClean the CCD faceplate with care Do not attempt to disassemble the cameraWV-BP334 Major Operating Controls and Their FunctionsLens option Camera Mounting Screw Hole Auto Iris lens ConnectorFlange-back Adjusting Ring Power Cord only WV-BP3306Video Output Connector Video OUT 1Back Light Compensation Mode Selector BLC2Lens Drive Signal Selector VIDEO, DC 4Vertical Phase Control Phase only WV-BP330 and WV-BP3347Gen-lock Input Connector GEN-LOCK WV-BP332 12V DC ConnectionsVideo Cable Type RG-59/U RG-6/U RG-11/U RG-15/U Coaxial cable Installation of Auto Iris Lens Connector Mounting the Lens Focus or FLANGE-BACK Adjustment Mounting from the bottom Installation of CameraPrevention of Blooming and Smear Specifications Standard Accessories Video Imaging Systems Company