AXIS 211M - I/O Terminal Connector
I/O Terminal Connector
The I/O terminal connector is used in applications such as motion detection, event triggering, time lapse recording and alarm notifications. It provides the interface to:
•1 transistor output - For connecting external devices such as relays and LEDs. Con- nected devices can be activated by AXIS VAPIX AP, output buttons on the Live View page or by an Event Type. The output will show as active (shown under Event Config- uration > Port Status) if the alarm device is activated.
•1 digital input - An alarm input for connecting devices that can toggle between an open and closed circuit, for example: PIRs, door/window contacts, glass break detectors, etc. When a signal is received the state changes and the input becomes active (shown under Event Configuration > Port Status).
•Auxiliary power and GND
Pin 4 | Pin 2 |
Pin 3 | Pin 1 |
Terminal connector. Note that the pins are numbered
Function | Pin number | Notes | Specifications |
|
|
|
|
GND | 1 |
|
|
|
|
|
|
5V DC Power | 2 | Can be used as an alternative power supply | Max load = 100mA |
|
| auxiliary equipment +5VDC (100mA). |
|
|
|
|
|
Digital Input | 3 | Connect to GND to activate, or leave floating (or unconnected) to | Must not be exposed to voltages greater |
|
| deactivate. | than |
|
|
| 20VDC |
|
|
|
|
Transistor Output | 4 | Uses an | Max load =100mA |
|
| to the GND pin. If used with an external relay, a diode must be | Max voltage = 24VDC |
|
| connected in parallel with the load, for protection against voltage | (to the transistor) |
|
| transients. |
|
|
|
|
|
Connection diagram
AXIS 211M
5V
max. 100mA
1o
e.g. pushbutton
2o
z
3 o
4
o
34