26AXIS 207MW - Event Configuration
Please see the online help for descriptions of each available option.
| Object Size | History | Sensitivity |
|
|
|
|
High level | Only very large objects trig- | An object that appears in the | Ordinary colored objects on ordinary back- |
| ger motion detection | region will trigger the motion | grounds will trigger the motion detection |
|
| detection for a long period |
|
|
|
|
|
Low level | Even very small objects trig- | An object that appears in the | Only very bright objects on a dark background |
| ger motion detection | region will trigger motion | will trigger motion detection |
|
| detection for a very short |
|
|
| period |
|
|
|
|
|
Default value | Low | Medium to High | Medium to High |
|
|
|
|
Examples:
•Avoid triggering on small objects in the video image by setting the object size level to high.
•To reduce the number of triggers if there is a lot of movement during a short period of time, select a high history level.
•To only detect flashing light, low sensitivity can be selected. In other cases, a high sensitivity level is recommended.
Port Status
Under Event Configuration > Port Status there is a list showing the status for the camera’s input and output. This is for the benefit of Operators, who have no access to the System Options section.
Example: If the Normal state for a push button connected to an input is set to Open circuit - as long as the but- ton is not pushed, the state is inactive. If the button is pushed, the state of the input changes to active.