Classe Audio CA-D200 RJ-45 DB9 female adaptor, USB Port, AC Mains Input, AC Mains Fuse

Page 13

Danger!

RJ-45 - DB9 female adaptor

If your RS-232 control system uses a cable with a male DB9 connector, you will need to buy or build an adaptor to convert the RJ-45 female to a DB9 female. Standard RJ45-to-DB9 female connectors come with RJ-45 pins and colors as below. Wire the DB9 adaptor according to this diagram and table.

RJ-45

DB9

 

Pin-1 = Blue

Pin-1 = Brown

Pin-2 = Orange

Pin-2 = Green

Pin-3 = Black

Pin-3 = Yellow

Pin-4 = Red

Pin-4 = Orange

Pin-5

= Green

Pin-5 = Red

Pin-6

= Yellow

Pin-6 = Blue

Pin-7

= Brown

Pin-7

= NC

Pin-8

= White

Pin-8

= Black

 

 

Pin-9

= White

Remarks: The Cat 5 cable and connector that is used for the adaptor and plugs into the rear panel RJ-45 port must use pin-to-pin wiring.

8USB Port

The USB connector is used to host a USB stick for updating amplifier firmware, should that become necessary.

9AC Mains Input

An IEC standard power cord (supplied) is used with the CA-D200. Plug the cord into the IEC receptacle on the rear panel, and the other end into a suitable wall outlet.

10AC Mains Fuse

Your Classé power amplifier has an AC mains fuse, accessible on the rear panel. If you suspect that your AC fuse has blown, disconnect your amplifier from the AC mains, as well as from its input connections and speaker connections, and refer to the appropriate item of the section enitled Troubleshooting.

Do not open your amplifier. There are no user-serviceable parts within this product.

Potentially dangerous voltages and current capabilities exist within your power amplifier, even when disconnected from AC mains. Do not attempt to open any portion of the amplifier’s cabinet. There are no user-serviceable parts inside your power amplifier. All service of this product must be referred to a qualified Classé dealer or distributor.

13

Image 13
Contents CA-D200 Two-Channel Amplifier Class Important Safety Instructions Contents Welcome to the Classé family Word about installationUnpacking and Placement Warm up/break-in period Please read this manual… Special Design Features Front Panel Standby button & LED status indicatorOn red Flashing blueBalanced XLR Input Rear PanelSpeaker Outputs Single-Ended RCA InputClassé CAN-Bus Control Ports IR Input and OutputRS 232 Control Port DC Trigger Input and OutputRJ-45 RJ-45 DB9 female adaptorUSB Port AC Mains InputConfigure your amplifier turn-on delay/amp number InstallationMake your preamp/processor connections Make your speaker connections CAN-BusDouble-check all your connections CAN-Bus will allow a Classé touchscreen toCategory 5 Network Cables Classé CAN-Bus Equipped ProductsCAN-Bus equipped components in your system CAN-Bus Terminator SSP-300 & 600 CAN-Bus Interface BoxFor any system with SSP-300 or SSP-600 Any combination of models in any orderFollowing CAN-Bus features are shared by all models CAN-Bus shared featuresPlayLink Following CAN-Bus features are model specificAmp info Event log Care and Maintenance No sound, and Standby LED is not lit TroubleshootingNo sound, and Standby LED is blinking red Protection circuitry has been engagedMains voltage 100-120VAC Fuse type AC mains fuse is blownRating 3AH Mains voltage 200-240VAC Fuse type Rating 15AHSpecifications CA-D200 DimensionsPage +1 514 +1 514 636-1428 fax François Cusson Lachine, QuebecNorth America 514