Sharp PN-Y475, PN-Y555, PN-Y425 37 E, Controlling the Monitor with a PC RS-232C Setup menu, Others

Page 37

Controlling the Monitor with a PC (RS-232C)

SETUP menu

 

Function

Command

Direction

Parameter

Reply

Control/Response contents

*

DATE/TIME SETTING

DATE

WR

AABBCCDDEE

AABBCCDDEE

AA: Year, BB: Month, CC: Day, DD: Hour, EE: Minute

 

 

 

 

 

 

 

 

 

 

ID SETTING

 

ID NO.SETTING

IDST

W

0-25

 

Sets the monitor’s ID number. (“0” means “no ID number”.)

 

 

 

 

 

R

 

0-25

Returns the monitor’s ID number.

 

 

 

ID NO. SETTING

IDSL

W

1-25

 

Sets a monitor ID number.

 

 

 

(ONCE)

 

 

 

 

This ID number is only effective for the command immediately after this

 

 

 

 

 

 

 

 

command.

 

 

 

 

 

 

0

 

Clears the ID number if one has been designated.

 

 

 

ID NO. SETTING

IDLK

W

1-25

 

Sets a monitor ID number.

 

 

 

(SUBSEQUENT)

 

 

 

 

This ID number is effective for the next and all subsequent commands after this

 

 

 

 

 

 

 

 

command.

 

 

 

 

 

 

0

 

Clears the ID number if one has been designated.

 

 

 

 

 

 

 

 

 

 

MULTI

 

ENLARGE

ENLG

WR

0-1

0-1

0: OFF, 1: ON

 

 

 

ENLARGE MODE

EMHV

WR

11-55

11-55

1 x 1 (OFF) to 5 x 5 (“m x n” is expressed as “mn”, where m and n are the

 

 

 

 

 

 

 

numbers of monitors specified for the longest direction and the shortest direction

 

 

 

 

 

 

 

respectively.)

 

 

 

IMAGE POSITION

EPHV

WR

11-55

11-55

Specifies values in the order of IMAGE POSITION IN LONGEST/ SHORTEST

 

 

 

(M x N)

 

 

 

 

DIRECTION.

 

 

 

BEZEL ADJUST

BZCO

WR

0-1

0-1

0: OFF, 1: ON

 

 

 

ENLARGE/

ESHV

WR

XXYY

XXYY

XX: ENLARGE MODE (Same as EMHV), YY: IMAGE POSITION (Same as

 

 

 

IMAGE POSITION

 

 

 

 

EPHV)

 

 

 

SETTING

 

 

 

 

 

 

THERMAL SENSOR SETTING

STDR

WR

0-1

0-1

0: LANDSCAPE, 1: PORTRAIT

 

ADJUSTMENT

 

MONITOR

ALCM

WR

0-1, 3

0-1, 3

0: UNLOCKED, 1: LOCK ALL, 3: LOCK EXCEPT POWER

 

LOCK

 

BUTTONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REMOTE

ALCR

WR

0-3

0-3

0: UNLOCKED, 1: LOCK ALL, 2: LOCK EXCEPT VOLUME,

 

 

 

CONTROL

 

 

 

 

3: LOCK EXCEPT POWER

 

Others

 

Function

Command

Direction

Parameter

Reply

Control/Response contents

*

 

 

 

 

 

 

 

 

 

VOLUME

 

 

VOLM

WR

0-31

0-31

 

MUTE

 

 

MUTE

WR

0-1

0-1

0: OFF, 1: ON

-

INFORMATION

 

MODEL

INF1

R

 

Value

 

 

 

 

SERIAL NO

SRNO

R

 

Value

 

 

TEMPERATURE SENSOR

DSTA

R

 

0

Internal temperature normal

 

 

 

 

 

 

 

1

Internal temperature abnormal has occurred and the monitor is in standby mode

 

 

 

 

 

 

 

2

Internal temperature abnormal occurred (To delete the information of temperature

 

 

 

 

 

 

 

 

abnormal, turn off the main power.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Internal temperature abnormal has occurred and backlight brightness is dimmed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Temperature sensor abnormal

 

 

 

 

 

 

 

 

TEMPERATURE ACQUISITION

ERRT

R

 

Value

Returns the temperature at the temperature sensors in the following format.

 

 

 

 

 

 

 

 

[Sensor 1]

 

CAUSE OF LAST STANDBY MODE

STCA

W

0

 

Initialization

 

 

 

 

R

 

0

No detectable error has occurred

 

 

 

 

 

 

 

 

 

 

 

 

1

Standby mode by POWER button

 

 

 

 

 

 

 

3

Standby mode by RS-232C or LAN

 

 

 

 

 

 

 

4

Input signal waiting mode by No Signal

 

 

 

 

 

 

 

6

Standby mode by abnormal temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

Standby mode by SCHEDULE setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

Standby mode by OFF IF NO OPERATION setting

 

 

 

 

 

 

 

 

 

 

LAN SETUP

 

USERNAME

USER

WR

XXXXXXXX

XXXXXXXX

X: Eight characters or less; half-width alphanumeric characters, "-", and "_".

 

 

 

 

 

 

 

 

(The field can be left blank, but spaces cannot be entered.)

 

 

 

PASSWORD

PASS

WR

XXXXXXXX

XXXXXXXX

X: Eight characters or less; half-width alphanumeric characters, "-", and "_".

 

 

 

 

 

 

 

 

(The field can be left blank, but spaces cannot be entered.)

 

TIPS

• Some menu setting items do not have a command. Set with the remote control during installation.

37 E

Image 37
Contents PN-Y555 PN-Y475 PN-Y425 Page GREEN-AND-YELLOW For Customers in U.KBlue BrownDear Sharp Customer Safety Precautions Safety Precautions Tips and Safety Instructions For the monitor in portrait orientation For the monitor in landscape orientationDo not place the monitor on a device which generates heat Supplied Components ContentsPart Names LCD panel Remote control sensor SeeSub input terminal See Signal transmitter NRemote control unit Part Names11 E Return button See SIZE/Yellow button SeeConnecting Peripheral Equipment 13 E Connecting Peripheral EquipmentBinding Cables Connecting the Power CordAttachment PN-Y425Affixing the Stand Hole Protection Covers Setting the USB flash drive cover15 E USB port USB flash drive cover screwInstalling the batteries Preparing the Remote Control UnitRemote control operation range Turning power on/off Turning Power On/OffTurning on the main power 17 ENDate/time setting Turning Power On/Off NOperation modeSetting of the Setup menu. Be sure to set the date and time 19 E Basic OperationNormal Wide Basic Operation NSwitching the screen sizeDot by Dot 21 E Playing the Files in a USB Flash DriveAuto playback Playing filesPhoto Playing files using the Schedule functionMovie Music23 E SettingsOperations during play Color Mode Playing the Files in a USB Flash Drive Settings during playVolume Size25 E Menu ItemsDisplaying the menu screen NExample of operationMenu Items Menu item detailsNSCREEN NPICTURE27 E NSETUPMenu Items NAUDIO Power on Delay Standby ModeScan Mode Hdmiav Adjustment LockSet using Multi in the Setup menu Setting procedure29 E Menu Items NEnlargeMenu Items NSCHEDULE Opening the adjustment pattern Menu Items NScreen display for adjustment31 E ScheduleControlling the Monitor with a PC RS-232C Communication procedureCommunication conditions PC connection33 E NID SettingNResponse code format VOLM0030 002VOLM0020 ← OK 002 IDLK0000 ← Wait ← OK 002 ← VOLM0010 OK 001 ←Volume settings for all monitors are returned NRepeater control command35 E Controlling the Monitor with a PC RS-232C NRepeater controlPower control/Input mode selection RS-232C command tableControlling the Monitor with a PC RS-232C Screen menu37 E Controlling the Monitor with a PC RS-232C Setup menuOthers Controlling the Monitor with a PC LAN Settings to connect to a LANTo set on the monitor Character input39 E Command-based controlControlling the Monitor with a PC LAN Troubleshooting Power LED is flashing in red and green alternately Troubleshooting41 E NProduct Specifications SpecificationsSpecifications NDimensional Drawings43 E Dmpm Digital Monitor Power Management Specifications NPower managementNDDC plug and play NCompatible signal timing AV Specifications NCompatible signal timing PC45 E DVI-D HdmiNHDMI input terminal pins Specifications NDVI-D input terminal pinsND-sub input terminal pins NRS-232C input terminal pinsSpecifications NRS-232C output terminal pins NDVI-D output terminal pins47 E Mounting Precautions For Sharp dealers and service engineers PN-Y555-Y475-Y425 Me EN14G2

PN-Y425, PN-Y475, PN-Y555 specifications

The Sharp PN-Y475, PN-Y555, and PN-Y425 are part of Sharp's range of professional displays designed to meet the demands of contemporary business and educational environments. These displays boast impressive features and advanced technologies, making them ideal for various applications, including digital signage, presentations, and collaborative work.

One of the standout features across this series is their superior image quality. The displays utilize full HD (1920 x 1080) resolution, ensuring that images, videos, and text are sharp and vibrant. The PN-Y555, with its 55-inch screen size, is perfect for medium to large meeting rooms, while the PN-Y475 offers a 47-inch option for spaces where a slightly smaller display is required. The PN-Y425, featuring a 42-inch screen, is ideal for smaller settings or areas with limited space.

All three models incorporate advanced LED backlighting technology, which delivers energy-efficient performance and reliable brightness levels. This ensures consistent performance over long periods, making these displays suitable for extended use. Additionally, the anti-glare coating minimizes reflections and enhances visibility, making content easily viewable even in brightly lit environments.

Connectivity is another major highlight of the Sharp PN-Y series. Each model comes equipped with multiple input options, including HDMI, DisplayPort, and USB, making it easy to connect to a variety of devices such as computers, media players, and streaming devices. This flexibility enables seamless content sharing in collaborative environments.

For added functionality, the displays also support touchscreen capabilities (available on certain models), allowing for interactive presentations and engaging user experiences. This feature is especially beneficial in educational settings, where students can actively participate in learning.

Furthermore, the PN-Y series incorporates built-in speakers, providing clear audio output without the need for external audio systems, which simplifies setup and enhances the overall experience.

In summary, the Sharp PN-Y475, PN-Y555, and PN-Y425 are designed to deliver outstanding performance and versatility for professional environments. With their high-quality visuals, extensive connectivity options, and user-friendly features, they stand out as valuable tools for effective communication and collaboration. Whether for corporate presentations or educational purposes, these displays are equipped to enhance engagement and improve the flow of information in any setting.