Sharp PN-S655 manual 15 E, Controlling the Monitor with a PC RS-232C NRepeater control

Page 15

Controlling the Monitor with a PC (RS-232C)

nRepeater control

This system has a function to allow setting of multiple monitors connected in a daisy chain using a single command. This function is called repeater control. You can use Repeater control function without assigning ID numbers.

[Example]

Set 1

 

Set 2

 

Set 3

 

Set 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*If monitors are connected as shown above, you can execute a command like “Set all monitors’ input settings to PC1 DVI-D”.

nRepeater control command

Repeater control is achieved by setting the FOURTH

CHARACTER of the parameter to “+”.

Example:

VOLM030 +

Sets volume of all monitors to 30.

In repeater control, responses are returned by all the connected monitors.

If you want to determine that a value has been returned by a specific set, assign ID numbers to each monitor in advance. When some monitors do not return their responses, the probable cause is that the monitors could not receive the command or command processing is not complete. Do not send a new command.

Example: (When 4 monitors are connected, and assigned ID numbers: 1 through 4)

VOLM030 +

WAIT

OK 001

OK 002

OK 003

OK 004 ← If 4 monitors are connected in a chain, reliable operation can be ensured by sending a new command only after a reply has been returned by 4th (last) monitor.

Repeater control can also be used for reading settings.

Example:

VOLM ? ? ? +

WAIT

10001

20002

30003

30004

Volume settings for all monitors are returned.

TIPS

If repeater control is used during ID designation (IDSL,

IDLK), the ID designation is canceled.

15 E

Image 15
Contents PN-S655 Contents Display Basic OperationMute MenuCut off Basic Operation NSwitching the screen sizeWide Zoom Normal Dot by DotNMenu screen display Menu ItemsDisplaying the menu screen NExample of operationNPICTURE Menu item detailsMenu Items NSCREENMenu Items NOPTION NSETUPNENLARGE PC input NPIP/PbyPNDual screen display Menu Items NSCHEDULE NEnlargeNADVANCED items AV input See Adjustments for PC screen displayNAutomatic adjustment NScreen display for adjustment11 E Communication conditions Communication procedureControlling the Monitor with a PC RS-232C PC connection13 E NResponse code formatNID numbers OK 002 IDLK0000 ← Wait ← OK 002 ← VOLM0010 OK 001 ← 002VOLM0030 VOLM0020 ←Controlling the Monitor with a PC RS-232C NRepeater control NRepeater control commandVolume settings for all monitors are returned 15 EControlling the Monitor with a PC RS-232C RS-232C command tablePower control/Input mode selection How to read the command table17 E Controlling the Monitor with a PC RS-232C Picture menuAudio menu Option menu Controlling the Monitor with a PC RS-232C Setup menuPIP/PbyP menu Initialization/Functional Restriction Setting Function menuImage Position Epos setting 19 EControlling the Monitor with a PC RS-232C Others Temperature Sensor DstaTo set on the monitor Settings to connect to a LANControlling the Monitor with a PC LAN 21 EThis monitor is factory preset as shown below IP Address Default Gateway 0.0Controlling the Monitor with a PC LAN To set from a PC Basic operation 23 EControlling with a PC Controlling the Monitor with a PC LANControl Information AdjustmentNetwork LAN Setup 25 ENetwork Security Mail Originator Network General27 E Mail RecipientMail Periodical Service & Support URL Information URL InformationSpecify the condition to display the URL 29 E PN-S655 G EN08F1
Related manuals
Manual 30 pages 27.1 Kb