RS-232C command table

How to read the command table

 

Command:

Command field (See page 12.)

 

Direction:

W When the “Parameter” is set in the parameter field (see page 12), the command functions as described

 

under “Control/Response Contents”.

 

 

R The returned value indicated under “Reply” can be obtained by setting “????”, “

?” or “???+”

 

(repeater control) in the parameter field (see page 12).

 

Parameter:

Parameter field (See page 12.)

 

Reply:

Response (Returned value)

 

*:

“A” indicates a command which can be used in power standby mode regardless of the STANDBY MODE

 

setting.

 

 

“B” indicates command which can be used in power standby mode when STANDBY MODE is set to

 

STANDARD. (It cannot be used in the power standby mode when LOW POWER is selected.)

 

“–” indicates a command which cannot be used in power standby mode.

 

Power control/Input mode selection

Function

Command

Direction

Parameter

 

Reply

Control/Response contents

*

 

 

 

 

 

 

 

 

POWER CONTROL

POWR

W

 

0

 

Switches to standby mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

Returns from standby mode.

 

 

 

 

 

 

 

 

 

 

 

R

 

 

0

Standby mode

A

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Normal mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Input signal waiting mode

 

 

 

 

 

 

 

 

 

INPUT MODE SELECTION

INPS

W

 

0

 

Toggle change for input mode. Terminals not selected in DVI SELECT/

 

 

 

 

 

 

 

BNC SELECT/HDMI SELECT cannot be selected.

 

 

 

 

 

1

 

PC1 DVI-D

 

 

 

 

 

 

 

“ERR” when AV1 DVI-D is selected for DVI SELECT.

 

 

 

 

 

2

 

PC3 D-SUB

 

 

 

 

 

3

 

AV3 COMPONENT

 

 

 

 

 

 

 

“ERR” when PC4 RGB is selected for BNC SELECT.

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

AV5 VIDEO

 

 

 

 

 

 

 

 

B

 

 

 

 

6

 

PC4 RGB

 

 

 

 

 

 

“ERR” when AV3 COMPONENT is selected for BNC SELECT.

 

 

 

 

 

7

 

AV1 DVI-D

 

 

 

 

 

 

 

“ERR” when PC1 DVI-D is selected for DVI SELECT.

 

 

 

 

 

8

 

AV4 S-VIDEO

 

 

 

 

 

9

 

AV2 HDMI

 

 

 

 

 

 

 

“ERR” when PC2 HDMI is selected for HDMI SELECT.

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

PC2 HDMI

 

 

 

 

 

 

 

“ERR” when AV2 HDMI is selected for HDMI SELECT.

 

 

 

R

 

 

1

PC1 DVI-D

 

 

 

 

 

 

2

PC3 D-SUB

 

 

 

 

 

 

3

AV3 COMPONENT

 

 

 

 

 

 

4

AV5 VIDEO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

PC4 RGB

A

 

 

 

 

 

 

 

 

 

 

 

 

 

7

AV1 DVI-D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

AV4 S-VIDEO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

AV2 HDMI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

PC2 HDMI

 

SCREEN menu

 

Function

Command

Direction

Parameter

Reply

Control/Response contents

*

Auto

 

 

ASNC

W

1

 

When the input mode is PC3, PC4.

 

 

 

 

 

 

 

 

 

 

CLOCK

 

 

CLCK

WR

0-1200

0-1200

When the input mode is PC3, PC4. Varies depending on the signal.

 

 

 

 

 

 

 

 

 

 

PHASE

 

 

PHSE

WR

0-63

0-63

When the input mode is PC3, PC4.

 

 

 

 

 

 

 

 

 

 

positioning

 

Position of

HPOS

WR

0-100

0-100

0-800 on PC3/PC4.

 

 

 

the longest

 

 

 

 

Varies depending on the signal.

 

 

 

direction

 

 

 

 

 

 

 

 

Position of

VPOS

WR

0-100

0-100

0-200 on PC3/PC4.

 

 

 

the shortest

 

 

 

 

Varies depending on the signal.

 

 

 

direction

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

size

 

Position of

HSIZ

WR

0-100

0-100

 

 

 

the longest

 

 

 

 

 

 

 

 

direction

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Position of

VSIZ

WR

0-100

0-100

 

 

 

 

the shortest

 

 

 

 

 

 

 

 

direction

 

 

 

 

 

 

RESOLUTION

 

H-RESOLUTION

HRES

WR

300-1920

300-1920

When the input mode is PC3, PC4.

 

 

 

V-RESOLUTION

VRES

WR

200-1200

200-1200

Only even numbers are valid for parameters.

 

 

 

 

 

 

 

 

Varies depending on the signal.

 

RESET

 

 

ARST

W

1

 

 

 

E16

Image 16
Contents PN-S655 Contents Basic Operation MuteMenu DisplayBasic Operation NSwitching the screen size Wide Zoom NormalDot by Dot Cut offMenu Items Displaying the menu screenNExample of operation NMenu screen displayMenu item details Menu ItemsNSCREEN NPICTURENSETUP Menu Items NOPTIONNPIP/PbyP NENLARGE PC inputNDual screen display NEnlarge Menu Items NSCHEDULEAdjustments for PC screen display NAutomatic adjustmentNScreen display for adjustment NADVANCED items AV input See11 E Communication procedure Controlling the Monitor with a PC RS-232CPC connection Communication conditionsNResponse code format 13 ENID numbers 002 VOLM0030VOLM0020 ← OK 002 IDLK0000 ← Wait ← OK 002 ← VOLM0010 OK 001 ←NRepeater control command Volume settings for all monitors are returned15 E Controlling the Monitor with a PC RS-232C NRepeater controlRS-232C command table Power control/Input mode selectionHow to read the command table Controlling the Monitor with a PC RS-232CControlling the Monitor with a PC RS-232C Picture menu 17 EAudio menu Controlling the Monitor with a PC RS-232C Setup menu Option menuInitialization/Functional Restriction Setting Function menu Image Position Epos setting19 E PIP/PbyP menuTemperature Sensor Dsta Controlling the Monitor with a PC RS-232C OthersSettings to connect to a LAN Controlling the Monitor with a PC LAN21 E To set on the monitorDefault Gateway 0.0 This monitor is factory preset as shown below IP AddressControlling the Monitor with a PC LAN To set from a PC 23 E Controlling with a PCControlling the Monitor with a PC LAN Basic operationInformation Adjustment Control25 E Network LAN SetupNetwork Security Network General Mail OriginatorMail Recipient 27 EMail Periodical URL Information Service & Support URL InformationSpecify the condition to display the URL 29 E PN-S655 G EN08F1