Sharp PN-S655 manual Network General, Mail Originator

Page 26

Controlling the Monitor with a PC (LAN)

■ NETWORK (GENERAL)

This screen allows you to specify the general LAN settings.

MONITOR NAME

Specify a name for this monitor as it should appear on the Internet Explorer screen.

AUTO LOGOUT TIME

Specify the time (in minutes) to elapse before automatically disconnecting this monitor from the network.

Specify in minutes from 1 to 65535. A value of ‘0’ will disable this function.

DATA PORT

Specify the TCP port number to use for exchanging data with the monitor.

Specify a value from 1025 to 65535.

SEARCH PORT

Specify the port number to use when searching for this monitor.

Specify a value from 1025 to 65535.

TIPS

The MONITOR NAME can be up to 16 alphanumeric characters or symbols.

■ MAIL (ORIGINATOR)

This screen allows you to configure the e-mail sent periodically or when the monitor has an error.

The settings depend on the configuration of your LAN. Ask your LAN administrator for details.

SMTP SERVER

Specify the SMTP server address for sending e-mail.

*When using a domain name, make sure to specify the DNS server as well. (See page 25.)

ORIGINATOR E-MAIL ADDRESS

Specify the e-mail address for this monitor.

This address becomes the e-mail address of the originator.

ORIGINATOR NAME

Specify the name for the originator.

This name appears in the “Originator Name” field of the e-mail.

AUTHENTICATION

Specify the authentication method to use when sending e-mail.

POP SERVER

If the “AUTHENTICATION” method is “POP before SMTP”, specify the POP server address.

ACCOUNT NAME / PASSWORD

If the “AUTHENTICATION” method is “POP before SMTP”, specify the account name and password to connect to the POP server.

TIPS

You can enter up to 64 alphanumeric characters or symbols for the ORIGINATOR E-MAIL ADDRESS, ORIGINATOR NAME, ACCOUNT NAME, and PASSWORD.

The SMTP SERVER and POP SERVER can be up to 64 characters.

The following characters can be used: a-z, A-Z, 0-9, - , .

E26

Image 26
Contents PN-S655 Contents Menu Basic OperationMute DisplayDot by Dot Basic Operation NSwitching the screen sizeWide Zoom Normal Cut offNExample of operation Menu ItemsDisplaying the menu screen NMenu screen displayNSCREEN Menu item detailsMenu Items NPICTURENSETUP Menu Items NOPTIONNDual screen display NENLARGE PC inputNPIP/PbyP NEnlarge Menu Items NSCHEDULENScreen display for adjustment Adjustments for PC screen displayNAutomatic adjustment NADVANCED items AV input See11 E PC connection Communication procedureControlling the Monitor with a PC RS-232C Communication conditionsNID numbers 13 ENResponse code format VOLM0020 ← 002VOLM0030 OK 002 IDLK0000 ← Wait ← OK 002 ← VOLM0010 OK 001 ←15 E NRepeater control commandVolume settings for all monitors are returned Controlling the Monitor with a PC RS-232C NRepeater controlHow to read the command table RS-232C command tablePower control/Input mode selection Controlling the Monitor with a PC RS-232CAudio menu 17 EControlling the Monitor with a PC RS-232C Picture menu Controlling the Monitor with a PC RS-232C Setup menu Option menu19 E Initialization/Functional Restriction Setting Function menuImage Position Epos setting PIP/PbyP menuTemperature Sensor Dsta Controlling the Monitor with a PC RS-232C Others21 E Settings to connect to a LANControlling the Monitor with a PC LAN To set on the monitorControlling the Monitor with a PC LAN To set from a PC This monitor is factory preset as shown below IP AddressDefault Gateway 0.0 Controlling the Monitor with a PC LAN 23 EControlling with a PC Basic operationInformation Adjustment ControlNetwork Security Network LAN Setup25 E Network General Mail OriginatorMail Periodical 27 EMail Recipient Specify the condition to display the URL Service & Support URL InformationURL Information 29 E PN-S655 G EN08F1