Sharp PN-S655 manual 11 E

Page 11

Initialization (Reset)/Functional Restriction Setting

You can return the settings to their factory-preset values and restrict operations.

1.After pressing SIZE for about 5 seconds, press , , , and in that order.

FUNCTION

1/1

 

 

 

 

ALL RESET

 

 

 

ADJUSTMENT LOCK

OFF

 

RS-232C/LAN

UNLOCKED

 

OSD DISPLAY

ON

 

LED

ON

 

TEMPERATURE ALERT

LED

 

STATUS ALERT

OFF

 

 

 

END[MENU]

2.Select and set the items.

ALL RESET

Resets the settings to the factory default settings.

Press , select the resetting method, and then press

MENU .

After initialization, turn the main power switch off and then back on.

ALL RESET1.....Resets all the settings to the factory

default settings.

ALL RESET2.....Returns all settings to the factory default

settings except for the following items: LAN SETUP, RS-232C/LAN SELECT, NETWORK, MAIL, and SERVICE & SUPPORT (See page 7, and pages 25 to 28.)

ADJUSTMENT LOCK

You can disable operations on the monitor and the remote control unit that use buttons.

OFF....Enables operation.

1.........Disables all operations other than turning power

on/off and FUNCTION.

2.........Only the FUNCTION operation is enabled.

Disables all operations other than FUNCTION (not even power on/off).

RS-232C/LAN

Specifies whether to allow control via RS-232C or LAN (see pages 12 and 21).

OSD DISPLAY

Hides/shows menus.

The FUNCTION screen cannot be hidden.

LED

Specifies whether to light power LEDs.

TEMPERATURE ALERT

Selects the notification method for an abnormal

temperature.

 

OFF

Do not notify about an abnormal

 

temperature.

OSD & LED...

When an abnormal temperature is

 

detected, the power LED flashes in red

 

and green alternately and the screen

 

displays a message: TEMPERATURE.

LED

When an abnormal temperature is

 

detected, the power LED flashes in red

 

and green alternately.

STATUS ALERT

Selects the notification method for a hardware error.

OFF

Do not notify about the error.

OSD & LED...

When a hardware error is detected, the

 

power LED flashes in red and the screen

 

displays a message: STATUS [xxxx].

LED

When a hardware error is detected, the

 

power LED flashes in red.

3. Press MENU to return to the normal screen.

TIPS

When both abnormal temperature and hardware error are detected, the hardware error notification overrides.

11 E

Image 11
Contents PN-S655 Contents Display Basic OperationMute MenuCut off Basic Operation NSwitching the screen sizeWide Zoom Normal Dot by DotNMenu screen display Menu ItemsDisplaying the menu screen NExample of operationNPICTURE Menu item detailsMenu Items NSCREENMenu Items NOPTION NSETUP NDual screen display NENLARGE PC input NPIP/PbyP Menu Items NSCHEDULE NEnlargeNADVANCED items AV input See Adjustments for PC screen displayNAutomatic adjustment NScreen display for adjustment11 E Communication conditions Communication procedureControlling the Monitor with a PC RS-232C PC connectionNID numbers 13 ENResponse code format OK 002 IDLK0000 ← Wait ← OK 002 ← VOLM0010 OK 001 ← 002VOLM0030 VOLM0020 ←Controlling the Monitor with a PC RS-232C NRepeater control NRepeater control commandVolume settings for all monitors are returned 15 EControlling the Monitor with a PC RS-232C RS-232C command tablePower control/Input mode selection How to read the command tableAudio menu 17 EControlling the Monitor with a PC RS-232C Picture menu Option menu Controlling the Monitor with a PC RS-232C Setup menuPIP/PbyP menu Initialization/Functional Restriction Setting Function menuImage Position Epos setting 19 EControlling the Monitor with a PC RS-232C Others Temperature Sensor DstaTo set on the monitor Settings to connect to a LANControlling the Monitor with a PC LAN 21 EControlling the Monitor with a PC LAN To set from a PC This monitor is factory preset as shown below IP AddressDefault Gateway 0.0 Basic operation 23 EControlling with a PC Controlling the Monitor with a PC LANControl Information AdjustmentNetwork Security Network LAN Setup25 E Mail Originator Network GeneralMail Periodical 27 EMail Recipient Specify the condition to display the URL Service & Support URL InformationURL Information 29 E PN-S655 G EN08F1