Sharp PN-S655 manual 13 E, NResponse code format, NID numbers

Page 13

nResponse code format

When a command has been executed correctly

O

K

 

 

 

Return code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(0DH, 0AH)

A response is returned after a command is executed. * If an ID number has been assigned

 

 

 

Space (20H)

 

Return code

 

 

 

 

(0DH, 0AH)

 

 

 

 

 

 

 

 

 

 

O

K

SPC

0

0

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ID number of responding monitor

When a command has not been executed

ER R Return code (0DH, 0AH)

*If an ID number has been assigned

 

Space (20H)

Return code

 

 

 

 

 

(0DH, 0AH)

 

 

 

 

 

 

 

 

 

 

E

R

R

SPC

0

0

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ID number

Controlling the Monitor with a PC (RS-232C)

nCommunication interval

After OK or ERR is returned, you must send the following commands.

To set a timeout for the command response, specify 10 seconds or longer.

Provide an interval of 100 ms or more between the command response and the transmission of the next command.

VOLM0020

OK

Interval of 100 ms or more

INPS0001

WAIT

OK

TIPS

When executing ALL RESET, set the timeout period to 30 seconds or longer.

When turning the power on while the POWER ON DELAY function is in use, set the timeout period to the POWER ON DELAY period + 10 seconds or longer.

TIPS

“ERR” is returned when there is no relevant command or when the command cannot be used in the current state of the monitor.

If communication has not been established for reasons such as a bad connection between the PC and monitor, nothing is returned (not even ERR).

If no monitor has been assigned the designated ID number

(e.g. if the command IDSL0002 is used, but no monitor with ID number: 2 is found), no response is returned.

If RS-232C/LAN COMMAND is set to options other than

NORMAL, the return code for a response is 0DH only.

Advanced operation

This section explains commands for daisy chain connection. The basic communication procedure is the same as in the “One-to-one connection with a PC” section.

nID numbers

You can assign a unique ID number to each monitor (see page 7). This allows you to control a particular monitor in a daisy chain of monitors.

You can assign ID numbers either from the menu screen (using the remote control) or from the PC using RS-232 cable.

[Example]

ID number: 1 ID number: 2 ID number: 3 ID number: 4

If execution of the command is taking some time

W

A

I

T

 

 

 

 

Return code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(0DH, 0AH)

When the following commands are used, “WAIT” is returned. In this case, a value will be returned if you wait a while. Do not send any command during this period.

No ID number is attached to WAIT response.

Commands which return WAIT:

1.When repeater control is used

2.When an IDSL or IDLK command is used

3.When one of the following commands is used: RSET, INPS, ASNC, WIDE, EMAG, EPOS, PXSL, POWR, AGIN, MWIN, MWIP, MWPP, ESTG, EMHV, EPHV,

ESHV

If monitors are connected as shown above, you can execute commands like “Set the volume of the monitor with ID 4 to 20”.

When controlling monitors linked in a daisy chain by designating ID numbers, you should basically avoid any duplication of ID numbers.

ID numbers do not have to be assigned in ascending order starting from the PC. They can also be connected as shown below.

[Example]

ID number: 3 ID number: 2 ID number: 4 ID number: 1

When control via RS-232C is locked (to prevent use) using the operation lock function (see page 11)

L

O

C

K

E

D

Return code (0DH, 0AH)

When RS-232C/LAN SELECT is set to LAN

U N S E L E C T E D

Return code (0DH, 0AH)

13 E

Image 13
Contents PN-S655 Contents Mute Basic OperationMenu DisplayWide Zoom Normal Basic Operation NSwitching the screen sizeDot by Dot Cut offDisplaying the menu screen Menu ItemsNExample of operation NMenu screen displayMenu Items Menu item detailsNSCREEN NPICTUREMenu Items NOPTION NSETUPNPIP/PbyP NENLARGE PC inputNDual screen display Menu Items NSCHEDULE NEnlargeNAutomatic adjustment Adjustments for PC screen displayNScreen display for adjustment NADVANCED items AV input See11 E Controlling the Monitor with a PC RS-232C Communication procedurePC connection Communication conditionsNResponse code format 13 ENID numbers VOLM0030 002VOLM0020 ← OK 002 IDLK0000 ← Wait ← OK 002 ← VOLM0010 OK 001 ←Volume settings for all monitors are returned NRepeater control command15 E Controlling the Monitor with a PC RS-232C NRepeater controlPower control/Input mode selection RS-232C command tableHow to read the command table Controlling the Monitor with a PC RS-232CControlling the Monitor with a PC RS-232C Picture menu 17 EAudio menu Option menu Controlling the Monitor with a PC RS-232C Setup menuImage Position Epos setting Initialization/Functional Restriction Setting Function menu19 E PIP/PbyP menuControlling the Monitor with a PC RS-232C Others Temperature Sensor DstaControlling the Monitor with a PC LAN Settings to connect to a LAN21 E To set on the monitorDefault Gateway 0.0 This monitor is factory preset as shown below IP AddressControlling the Monitor with a PC LAN To set from a PC Controlling with a PC 23 EControlling the Monitor with a PC LAN Basic operationControl Information Adjustment25 E Network LAN SetupNetwork Security Mail Originator Network GeneralMail Recipient 27 EMail Periodical URL Information Service & Support URL InformationSpecify the condition to display the URL 29 E PN-S655 G EN08F1
Related manuals
Manual 30 pages 27.35 Kb