Sharp PN-S655 Controlling the Monitor with a PC RS-232C, PC connection, Communication conditions

Page 12

Controlling the Monitor with a PC (RS-232C)

You can control this monitor from a PC via RS-232C (COM port) on the PC.

You can also connect multiple monitors via a daisy chain by using a PC. By assigning ID numbers to each monitor (see page 13), you can make input mode selection/adjustment or can check the status of a specific monitor.

Caution

To control the monitor via RS-232C, set RS-232C/LAN

SELECT to RS-232C.

You cannot use RS-232C and LAN control simultaneously.

PC connection

nOne-to-one connection with a PC

Connect with RS-232 straight cable between the PC’s COM port (RS-232C connector) and the RS-232C input terminal on the monitor.

RS-232C input terminal

PC

To COM port

RS-232 straight cable (commercially available)

nDaisy chain connection… Advanced operation

Connect with RS-232 straight cable between the PC’s COM port (RS-232C connector) and the RS-232C input terminal on the first monitor.

Next, connect RS-232 straight cable to the first monitor’s RS‑232C output terminal and to the second monitor’s RS-232C input terminal. Connect in the same way to the third and subsequent monitors.

Up to 25 monitors can be connected. (Depending on the length of the cable used and the surrounding environment.)

First monitor

 

Second monitor

RS-232C input terminal

RS-232C output terminal

Communication conditions

Set the RS-232C communication settings on the PC to match the monitor’s communication settings as follows:

Baud rate

9600 bps

 

Stop bit

1 bit

 

 

 

 

 

Data length

8 bits

 

Flow control

None

 

 

 

 

 

Parity bit

None

 

 

 

 

 

 

 

 

Communication procedure

nCommand format

When a command is sent from the PC to the monitor, the monitor operates according to the received command and sends a response message to the PC.

 

 

 

 

 

 

 

 

 

 

Return code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C1

 

C2

C3

 

C4

 

P1

P2

P3

P4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Command field

 

 

 

Parameter field

 

 

(4 prescribed

 

 

(4 character string comprised of:

alphanumerical characters)

 

0-9, +, -, space, ?)

Example: VOLM0030

VOLM 30

*Be sure to input 4 characters for the parameter. Pad with spaces (“ ”) if necessary.

(“ ” is a return code (0DH, 0AH or 0DH)) Wrong : VOLM30

Right : VOLM

30

When inputting a negative value, specify a numerical value in three digits.

Example: AUTR-009

Do not use spaces for MPOS, DATE, and SC01 through SC08. Specify parameters using a specified number of characters.

Example: MPOS010097

If a command has “R” listed for “DIRECTION” in the “RS-232C command table” on page 16, the current value can be returned by using “?” as the parameter.

Example:

VOLM ? ? ? ?

 

From PC to monitor (How much

 

 

 

 

is current volume setting?).

30

 

 

From monitor to PC (Current

 

 

 

 

volume setting: 30).

* If an ID number (see page 13) has been assigned

(For example, ID number = 1).

VOLM

?

From PC to monitor.

30

001

 

From monitor to PC.

PC

To COM port

RS-232 straight cables

(commercially available)

 

E12

Image 12
Contents PN-S655 Contents Basic Operation MuteMenu DisplayBasic Operation NSwitching the screen size Wide Zoom NormalDot by Dot Cut offMenu Items Displaying the menu screenNExample of operation NMenu screen displayMenu item details Menu ItemsNSCREEN NPICTURENSETUP Menu Items NOPTIONNENLARGE PC input NPIP/PbyPNDual screen display NEnlarge Menu Items NSCHEDULEAdjustments for PC screen display NAutomatic adjustmentNScreen display for adjustment NADVANCED items AV input See11 E Communication procedure Controlling the Monitor with a PC RS-232CPC connection Communication conditions13 E NResponse code formatNID numbers 002 VOLM0030VOLM0020 ← OK 002 IDLK0000 ← Wait ← OK 002 ← VOLM0010 OK 001 ←NRepeater control command Volume settings for all monitors are returned15 E Controlling the Monitor with a PC RS-232C NRepeater controlRS-232C command table Power control/Input mode selectionHow to read the command table Controlling the Monitor with a PC RS-232C17 E Controlling the Monitor with a PC RS-232C Picture menuAudio menu Controlling the Monitor with a PC RS-232C Setup menu Option menuInitialization/Functional Restriction Setting Function menu Image Position Epos setting19 E PIP/PbyP menuTemperature Sensor Dsta Controlling the Monitor with a PC RS-232C OthersSettings to connect to a LAN Controlling the Monitor with a PC LAN21 E To set on the monitorThis monitor is factory preset as shown below IP Address Default Gateway 0.0Controlling the Monitor with a PC LAN To set from a PC 23 E Controlling with a PCControlling the Monitor with a PC LAN Basic operationInformation Adjustment ControlNetwork LAN Setup 25 ENetwork Security Network General Mail Originator27 E Mail RecipientMail Periodical Service & Support URL Information URL InformationSpecify the condition to display the URL 29 E PN-S655 G EN08F1