■ MAIL (RECIPIENT)

This screen allows you to specify the recipients of the e-mail sent periodically or when the monitor has an error.

RECIPIENT E-MAIL ADDRESSES

Specify the e-mail addresses to send error notification e-mail to.

CONDITION

Specify the conditions to send mails.

When you check PERIODICAL, specify the date and time to send the mails in the PERIODICAL setting.

CONFIRMATION

Sends test e-mail.

This allows you to confirm that the e-mail settings are configured properly.

Attach the log file to a TEMPERATURE/HARDWARE error e-mail

When this option is checked, a log is added to the mail which notifies a temperature or status error.

TIPS

The RECIPIENT E-MAIL ADDRESSES can be up to 64 alphanumeric characters or symbols.

Controlling the Monitor with a PC (LAN)

■ MAIL (PERIODICAL)

When PERIODICAL for CONDITION of MAIL (RECIPIENT) is checked, set the date and time to send the mail.

DAY OF THE WEEK

Specify the day of the week to send the periodical mails.

TIME

Specify the time of the day to send the periodical mails.

Caution

Do not turn off the main power when you set to send the periodical mails.

Specify the correct date and time. (See page 7.)

If the date and time settings are incorrect, the periodical mail is not sent properly.

Regularly confirm that the specified date and time is correct.

27 E

Image 27
Contents PN-S655 Contents Display Basic OperationMute MenuCut off Basic Operation NSwitching the screen sizeWide Zoom Normal Dot by DotNMenu screen display Menu ItemsDisplaying the menu screen NExample of operationNPICTURE Menu item detailsMenu Items NSCREENMenu Items NOPTION NSETUPNENLARGE PC input NPIP/PbyPNDual screen display Menu Items NSCHEDULE NEnlargeNADVANCED items AV input See Adjustments for PC screen displayNAutomatic adjustment NScreen display for adjustment11 E Communication conditions Communication procedureControlling the Monitor with a PC RS-232C PC connection13 E NResponse code formatNID numbers OK 002 IDLK0000 ← Wait ← OK 002 ← VOLM0010 OK 001 ← 002VOLM0030 VOLM0020 ←Controlling the Monitor with a PC RS-232C NRepeater control NRepeater control commandVolume settings for all monitors are returned 15 EControlling the Monitor with a PC RS-232C RS-232C command tablePower control/Input mode selection How to read the command table17 E Controlling the Monitor with a PC RS-232C Picture menuAudio menu Option menu Controlling the Monitor with a PC RS-232C Setup menuPIP/PbyP menu Initialization/Functional Restriction Setting Function menuImage Position Epos setting 19 EControlling the Monitor with a PC RS-232C Others Temperature Sensor DstaTo set on the monitor Settings to connect to a LANControlling the Monitor with a PC LAN 21 EThis monitor is factory preset as shown below IP Address Default Gateway 0.0Controlling the Monitor with a PC LAN To set from a PC Basic operation 23 EControlling with a PC Controlling the Monitor with a PC LAN Control Information AdjustmentNetwork LAN Setup 25 ENetwork Security Mail Originator Network General27 E Mail RecipientMail Periodical Service & Support URL Information URL InformationSpecify the condition to display the URL 29 E PN-S655 G EN08F1